arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1506.08252astro-ph.IM
收藏

基于光束位移棱镜的三波段恒星光偏振仪

A beam-displacement prism based, three band stellar photo-polarimeter

A. V. Raveendran, G. Srinivasulu, S. Muneer, M. V. Mekkaden, N. Jayavel, M. R. Somashekar, K. Sagayanathan, S. Ramamoorthy, M. J. Rosario, K. Jayakumar

摘要:

印度天体物理研究所设计并制造了一台能同时测量三个波段点源线偏振的新型天文偏振仪。旋光仪有一个方解石光束位移棱镜作为分析器。利用高速旋转的斩波器,在同一个光电倍增管上准同时探测出射的各个光谱波段的寻常光束和非常光束。有效斩波频率可设置为高达200 Hz。旋转的超消色差Pancharatnam半波片用于调制入射到分析器上的光。使用适当的二向色和玻璃滤光片分离光谱带。详细的分析表明,偏振计效率的50%的减少,因为事实上,这两个光束的强度是交替测量的部分补偿减少的时间要花在观察天空背景。由格兰-泰勒棱镜在光路中产生的偏振的位置角被发现是轻微的波长依赖性,表明在光束中的固定的超消色差半波片不完全补偿旋转板的有效光轴的位置角的变化。然而,在U-I光谱区域中的总变化幅度仅为0.92度。偏振效率也被发现是波长相关的,在U-I区域的总振幅为0.271%,其平均值为99.211%。仪器极化被发现是非常低的。它在V-I光谱区几乎是恒定的(~0.04%),显然,它在紫外线附近略有增加。对偏振星的观测表明,所测偏振值与文献中的偏振值符合得很好。

英文摘要:

A new astronomical photo-polarimeter that can measure linear polarization of point sources simultaneously in three spectral bands was designed and built in Indian Institute of Astrophysics. The polarimeter has a Calcite beam-displacement prism as the analyzer. The ordinary and extra-ordinary emerging beams in each spectral band are quasi-simultaneously detected by the same photomultiplier by using a high speed rotating chopper. The effective chopping frequency can be set to as high as 200 Hz. A rotating superachromatic Pancharatnam halfwave plate is used to modulate the light incident on the analyzer. The spectral bands are isolated using appropriate dichroic and glass filters. A detailed analysis shows that the reduction of 50% in the efficiency of the polarimeter because of the fact that the intensities of the two beams are measured alternately is partly compensated by the reduced time to be spent on the observation of the sky background. The position angle of polarization produced by the Glan-Taylor prism in the light path is found to be slightly wavelength dependent, indicating that the fixed super-achromatic halfwave plate in the beam does not fully compensate for the variation in the position angle of the effective optical axis of the rotating plate. However, the total amplitude of variation in the U-I spectral region is only 0.92 degree. The polarization efficiency is also found to be wavelength-dependent with a total amplitude of 0.271% in the U-I region; its mean value is 99.211%. The instrumental polarization is found to be very low. It is nearly constant in the V-I spectral region (~0.04%), and apparently, it increases slightly towards the ultraviolet. The observations of polarized stars show that the agreement between the measured polarization values and those available in the literature to be excellent.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑