arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1303.6549astro-ph.IMphysics.ins-det
收藏

用于NASA GEMS布拉格反射偏振计的软X射线分束多层膜光学元件

A Soft X-ray Beam-splitting Multilayer Optic for the NASA GEMS Bragg Reflection Polarimeter

Ryan Allured, Monica Fernandez-Perea, Regina Soufli, Jennifer B. Alameda, Michael J. Pivovaroff, Eric M. Gullikson, Philip Kaaret

摘要:

研制了一种软X射线分束多层膜光学器件,用于NASA重力和极磁小型探测器任务(GEMS)的布拉格反射偏振计(BRP)。光学器件设计为通过90度角将0.5 keV X射线反射到BRP检测器,并将2-10 keV X射线传输到主偏振计。透射要求防止使用厚的基底,因此使用2微米厚的聚酰亚胺膜。原子力显微镜显示,膜具有高的空间频率粗糙度小于0.2 nm rms,允许足够的X射线反射率。特别开发了多层薄膜,并通过磁控溅射沉积,其反射率和透射率特性满足BRP要求并且具有接近零的应力。BRP原型元件的反射率和透射率测量结果在严格的环境测试之前和之后都与理论预测非常吻合。

英文摘要:

A soft X-ray, beam-splitting, multilayer optic has been developed for the Bragg Reflection Polarimeter (BRP) on the NASA Gravity and Extreme Magnetism Small Explorer Mission (GEMS). The optic is designed to reflect 0.5 keV X-rays through a 90 degree angle to the BRP detector, and transmit 2-10 keV X-rays to the primary polarimeter. The transmission requirement prevents the use of a thick substrate, so a 2 micron thick polyimide membrane was used. Atomic force microscopy has shown the membrane to possess high spatial frequency roughness less than 0.2 nm rms, permitting adequate X-ray reflectance. A multilayer thin film was especially developed and deposited via magnetron sputtering with reflectance and transmission properties that satisfy the BRP requirements and with near-zero stress. Reflectance and transmission measurements of BRP prototype elements closely match theoretical predictions, both before and after rigorous environmental testing.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑