When magnetic properties are analysed in a TEM using the technique of electron magnetic circular dichroism (EMCD), one of the critical parameters is the sample orientation, and this, independently on the chosen acquisition geometry. Since small orientation changes can have a strong impact on the EMCD measurement, it is experimentally non trivial to measure the EMCD signal as a function of sample orientation. The classical EMCD experimental setup requires to tilt the crystal in a 2 beam orientation and to acquire two electron energy loss spectra at two conjugate scattering angles. The effect of a mistilt from the perfect 2-beam orientation on the measured EMCD signals has not been explored yet due to different experimental constraints. In order to maintain the exact sample location and orientation for the acquisition of the EMCD signal, we have developed a methodology to simultaneously map the quantitative EMCD signals and the local orientation of the crystal. We analyse, both experimentally and with simulations, how the measured magnetic signals evolve with a change in the crystal tilt from the exact 2-beam orientation. Based on this analysis, we establish an accurate relationship between the crystal orientations and the EMCD signals. Our results demonstrate that a small crystal tilt away from the 2-beam orientation can significantly alter the strength and the distribution of the EMCD signals. From an optimisation of the crystal orientation, we obtain quantitative EMCD measurements.
Direct identification of local doping effects in Barium-hexaferrite by electron vortex beams
TUD Dresden University of Technology(德累斯顿工业大学);Johannes Kepler University(约翰内斯·开普勒大学);Donostia International Physics Center (DIPC)(圣塞巴斯蒂安国际物理中心);Indian Institute of Technology, Jodhpur(焦特普尔印度理工学院);Empa, Swiss Federal Laboratories for Materials Science and Technology(瑞士联邦材料科学与技术研究院);Uppsala University(乌普萨拉大学)
Brief Communication Arising from a Corrigendum to "Atomic-resolution chemical analysis using a scanning transmission electron microscope"
这份手稿最初是作为一份“简报”提交给《自然》杂志的,以回应2006年《自然》杂志上一篇早期论文的“勘误表”。《自然》杂志的一篇社论(2)指出,“作者歪曲了关键数据,无论是在审查过程中,还是在文件的最终出版版本中,它声称为他们的数据中的改变提供了解释,这些改变的效果是改变了他们的优先权要求,结果并不比Isaacson和Scheinfein之前的工作更好,比原子差1埃。分辨率达到了原子分辨率。在这份手稿中,我们表明,这种解释是物理上不一致的演变,他们的数据。当最初提交给《自然》杂志时,手稿经过了同行评审,被认为是“仔细和适当的论证”,并建议出版,并得到了勘误表作者的适当回应。随后与这些作者的交流没有达到令人满意的程度,也没有发表。我们现在已经了解到,《自然》杂志可能会刊登一篇文章,介绍围绕这份初始文件所表达的担忧的情况,我们认为这份文件和补充材料在公共领域提供是重要和相关的。关于优先权的适当归属问题,我们建议引用Batson同时进行的工作(3)。1.布朗宁,北达科他州,Chisholm,M.F.,和Pennycook,S.J. Corrigendum:Atomic-resolution chemical analysis using a scanning transmission电子显微镜,Nature 444,235(2006)。2.社论。更正还是撤回?Nature 444,123-…
Characterization of WSe$_2$ films using reflection Kikuchi diffraction in the scanning electron microscope and multivariate statistical analyses
University of British Columbia(不列颠哥伦比亚大学);Thermo Fisher Scientific(赛默飞世尔科技);Central European Institute of Technology, Brno University of Technology(布鲁诺理工大学中欧研究所);Institute of Physical Engineering, Brno University of Technology(布鲁诺理工大学物理工程学院);Thermo Fisher Scientific, Materials Science(赛默飞世尔科技材料科学部)
A low-temperature ultra-high-vacuum scanning probe microscope with in situ electronic transport capabilities: from macro to nano in 10 minutes
Universidad Autónoma de Madrid(马德里自治大学);Condensed Matter Physics Center (IFIMAC), Universidad Autónoma de Madrid(马德里自治大学凝聚态物理中心(IFIMAC));Instituto Nicolás Cabrera (INC), Universidad Autónoma de Madrid(马德里自治大学尼科拉斯·卡布雷拉研究所(INC));National Institute for Materials Science (NIMS)(国立材料研究所)
Mapping Unoccupied Electronic States of Freestanding Graphene by Angle-Resolved Low-Energy Electron Transmission
我们报告角分辨电子透射测量通过独立的石墨烯片在费米能级以上的能量范围为18至30 eV。测量在低能电子点源显微镜中进行,可以同时探测大角度范围的透射率。低能电子通过石墨烯的传输特性取决于其在真空能级以上的电子结构。这里描述的实验技术允许映射的未占用的能带结构的独立的二维材料作为能量和探测角度的函数,分别在平面动量。我们的实验发现与理论预测的真空水平以上的石墨烯能带结构共振一致[V.U. Nazarov,E. E. Krasovskii和V.M. Silkin,Physical Review B 87,041405(2013)]。