arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1106.4534cond-mat.mtrl-sci
收藏

由“用扫描透射电子显微镜进行原子分辨化学分析“的勘误引起的简要交流

Brief Communication Arising from a Corrigendum to "Atomic-resolution chemical analysis using a scanning transmission electron microscope"

John Silcox, David A. Muller

摘要:

这份手稿最初是作为一份“简报”提交给《自然》杂志的,以回应2006年《自然》杂志上一篇早期论文的“勘误表”。《自然》杂志的一篇社论(2)指出,“作者歪曲了关键数据,无论是在审查过程中,还是在文件的最终出版版本中,它声称为他们的数据中的改变提供了解释,这些改变的效果是改变了他们的优先权要求,结果并不比Isaacson和Scheinfein之前的工作更好,比原子差1埃。分辨率达到了原子分辨率。在这份手稿中,我们表明,这种解释是物理上不一致的演变,他们的数据。当最初提交给《自然》杂志时,手稿经过了同行评审,被认为是“仔细和适当的论证”,并建议出版,并得到了勘误表作者的适当回应。随后与这些作者的交流没有达到令人满意的程度,也没有发表。我们现在已经了解到,《自然》杂志可能会刊登一篇文章,介绍围绕这份初始文件所表达的担忧的情况,我们认为这份文件和补充材料在公共领域提供是重要和相关的。关于优先权的适当归属问题,我们建议引用Batson同时进行的工作(3)。1.布朗宁,北达科他州,Chisholm,M.F.,和Pennycook,S.J. Corrigendum:Atomic-resolution chemical analysis using a scanning transmission电子显微镜,Nature 444,235(2006)。2.社论。更正还是撤回?Nature 444,123-124(2006). 3.巴特森,P.E.(1993年)。同步STEM成像和具有原子柱灵敏度的电子能量损失谱。Nature 366,727-728.

英文摘要:

This manuscript was originally submitted to Nature for consideration as a "Brief Communication" in response to a "Corrigendum" that appeared in 2006 (1) to an earlier paper in Nature. That corrigendum was the subject of a Nature editorial (2) stating that "key data were misrepresented by the authors, both during the review process and in the final published version of the paper" and it claimed to provide an explanation for alterations in their data that had the effect of changing their priority claim from a result no better than previous work by Isaacson and Scheinfein that was 1 Angstrom shy of atomic resolution to what appeared to be atomic resolution. In this manuscript we show that this explanation is physically inconsistent with the evolution of their data. When originally submitted to Nature, the manuscript was peer-reviewed, deemed "carefully and properly argued" and recommended for publication with appropriate responses from the corrigendum authors. Subsequent exchanges with those authors did not reach a satisfactory state and publication did not occur. We now have learnt that an article is likely to appear in Nature concerning the circumstances surrounding the concerns expressed in this initial document and we consider it important and relevant that this document and the supplementary material be made available in the public domain. As to the question of proper attribution of priority, we would suggest instead citing the concurrent work of Batson (3). 1. Browning, N.D., Chisholm, M.F., and Pennycook, S.J. Corrigendum:Atomic-resolution chemical analysis using a scanning transmission electron microscope, Nature 444, 235 (2006). 2. Editorial. Correction or retraction? Nature 444, 123-124 (2006). 3. Batson, P.E. (1993). Simultaneous STEM imaging and electron energy-loss spectroscopy with atomic-column sensitivity. Nature 366, 727-728.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑