arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1909.02372physics.med-ph
收藏

一种模拟经颅MRI引导聚焦超声热消融的逐单元方法

An element-wise approach for simulating transcranial MRI-guided focused ultrasound thermal ablation

Nathan McDannold, P. Jason White, Rees Cosgrove

摘要:

这项工作探索了一种元素明智的方法来模拟经颅MRI引导的聚焦超声(TcMRgFUS)热消融,一种无创的神经外科方法。相控阵换能器的每个元件都被单独模拟,并且可以同时加载到计算机存储器中,从而可以快速计算用于波束转向和像差校正的不同相位偏移的压力场。我们模拟了32名患者的431次声处理的压力分布,应用了治疗期间使用的相位和幅度值,并估计了由此产生的温升。我们系统地改变了CT导出的颅骨密度与声衰减和声速之间的关系,以获得预测与MR温度成像(MRTI)之间的最佳一致性。通过模拟40种额外治疗的396次超声处理验证了优化。优化后,预测和测量的产热一致(R2:0.74例患者1-32; 0.71例患者33-72)。模拟温度图中加热的尺寸和密度与MRTI相关性良好(R2:分别为0.62,0.74),但测得的加热在空间上更分散。实现消融所需的能量变化了一个数量级(3.3-36.1 kJ)。虽然这种逐元素的方法需要更多的计算时间,但它可以并行执行。它允许在阵列上的不同相位和幅度值的焦点处的三维加热的快速计算。我们还展示了如何使用这种方法来优化CT衍生的颅骨密度和声学特性之间的关系。虽然这里发现的关系需要在更大的患者群体中进一步验证,但这些结果证明了这种方法对TcMRgFUS建模的前景。

英文摘要:

This work explored an element-wise approach to model transcranial MRI-guided focused ultrasound (TcMRgFUS) thermal ablation, a noninvasive approach to neurosurgery. Each element of the phased array transducer was simulated individually and could be simultaneously loaded into computer memory, allowing for rapid calculation of the pressure field for different phase offsets used for beam steering and aberration correction. We simulated the pressure distribution for 431 sonications in 32 patients, applied the phase and magnitude values used during treatment, and estimated the resulting temperature rise. We systematically varied the relationship between CT-derived skull density and the acoustic attenuation and sound speed to obtain the best agreement between the predictions and MR temperature imaging (MRTI). The optimization was validated with simulations of 396 sonications from 40 additional treatments. After optimization, the predicted and measured heating agreed well (R2: 0.74 patients 1-32; 0.71 patients 33-72). The dimensions and obliquity of the heating in the simulated temperature maps correlated well with the MRTI (R2: 0.62, 0.74 respectively), but the measured heating was more spatially diffuse. The energy needed to achieve ablation varied by an order of magnitude (3.3-36.1 kJ). While this element-wise approach requires more computation time up front, it can be performed in parallel. It allows for rapid calculation of the three-dimensional heating at the focus for different phase and magnitude values on the array. We also show how this approach can be used to optimize the relationship between CT-derived skull density and acoustic properties. While the relationships found here need further validation in a larger patient population, these results demonstrate the promise of this approach to model TcMRgFUS.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑