arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2307.11652physics.med-ph
收藏

用于超声引导下结节射频消融的拟人化甲状腺体模

An anthropomorphic thyroid phantom for ultrasound-guided radiofrequency ablation of nodules

Tim Boers, Wyger Brink, Leonardo Bianchi, Paola Saccomandi, Johan van Hespen, Germen Wennemars, Sicco Braak, Michel Versluis, Srirang Manohar

AI总结:

本文开发并验证了一种模拟甲状腺及周围关键结构的拟人化体模,通过多步骤模具浇铸和多种物理特性测试,证明其可用于超声引导下甲状腺结节射频消融的开发与培训。

摘要:

背景:基于针的操作,如细针穿刺(FNA)和热消融,常分别用于甲状腺结节的诊断和治疗目的。由于附近存在血管和神经,这些操作可能带来损伤周围关键结构的风险。目的:开发并验证用于管理这些风险的创新策略,需要一个具有明确物理特性的测试对象。本研究聚焦于超声引导下热射频消融(RFA)的应用。方法:我们开发了一种拟人化体模,模拟甲状腺及其周围与超声引导热消融相关的解剖和生理结构。该体模由聚丙烯酰胺、水和蛋清提取物的混合物组成,并通过多步骤模具浇铸而成。其热学、声学和电学特性均经过实验验证。利用凝固蛋清的弛豫计量变化,通过非破坏性T2加权MRI扫描分析消融区域,并使用光纤布拉格传感器阵列监测温度分布。结果:体模的物理特性在超声成像及其对热消融的响应方面均得到验证。最终达到的温度(92°C)、结节消融体积中位百分比(82.1%)、结节外消融体积中位数(0.8 mL)以及受影响关键结构的中位数量(0)均被量化。结论:本文提出了一种拟人化体模,可为超声引导下基于针的甲状腺结节热干预措施的开发和培训提供真实模型。未来,该模型还可扩展至新型基于针的诊断操作。

英文摘要:

Background: Needle-based procedures such as fine needle aspiration (FNA) and thermal ablation, are often applied for thyroid nodule diagnosis and therapeutic purposes, respectively. With blood vessels and nerves nearby, these procedures can pose risks in damaging surrounding critical structures. Purpose: The development and validation of innovative strategies to manage these risks require a test object with well-characterized physical properties. For this work, we focus on the application of ultrasound-guided thermal radio-frequency ablation (RFA). Methods: We have developed an anthropomorphic phantom mimicking the thyroid and surrounding anatomical and physiological structures that are relevant to ultrasound-guided thermal ablation. The phantom was composed of a mixture of polyacrylamide, water, and egg white extract and was cast using molds in multiple steps. The thermal, acoustical, and electrical characteristics were experimentally validated. The ablation zones were analyzed via non-destructive T2-weighted MRI scans utilizing the relaxometry changes of coagulated egg albumen, and the temperature distribution was monitored using an array of fiber Bragg sensors. Results: The physical properties of the phantom were verified both on ultrasound as well as its response to thermal ablation. The final temperature achieved (92°C), the median percentage of the nodule ablated (82.1%), the median volume ablated outside the nodule (0.8 mL), and the median number of critical structures affected (0) were quantified. Conclusion: An anthropomorphic phantom that can provide a realistic model for development and training in ultrasound-guided needle-based thermal interventions for thyroid nodules has been presented. In the future, this model can also be extended to novel needle-based diagnostic procedures.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑