收藏

利用改进的伯努利方程估计跨狭窄压力梯度

Trans-stenotic pressure drop estimation from PC-MRI and ultrasound imaging velocimetry using a modified Bernoulli equation

Delft University of Technology(代尔夫特理工大学)

Ali Amiri, Johan T. Padding, Selene Pirola, Willian Hogendoorn

AI总结:

本文提出改进的伯努利方程以更准确估计跨狭窄压力梯度,通过引入雷诺数依赖的损失系数,实验表明该方法在生理相关流量范围内优于传统方法,且MRI成像中峰值速度更抗采样误差。

摘要:

准确无创估计跨狭窄压力梯度仍具挑战性。临床实践中,压力梯度常通过速度测量利用伯努利公式估算,但这些简化关系未明确考虑压力损失随流动状态的变化。本文引入改进的伯努利(MB)公式,通过雷诺数依赖的损失系数考虑状态依赖的压力损失。在理想化狭窄模型中进行了稳态体外实验,覆盖生理相关流量速率(0.65-3.9 L/min),结合直接压力测量与超声成像测速和相位对比磁共振成像(PC-MRI)测量速度。MB模型从测量的压力降进行校准,然后与简化伯努利(SB)和扩展伯努利(EB)公式进行比较。在测试的流量范围内,MB与测量结果最为一致。SB和EB显示出较大的偏倚,误差约为10-55%(SB)和-15至25%(EB),且在临床相关范围内高估了压力降。此外,我们还量化了PC-MRI平面像素大小对MRI压力估计的影响。狭窄喉部的粗采样导致流量率和总体速度的系统低估,从而导致MB预测的压力降低估。相反,峰值喉部速度对像素大小的敏感性较低,当用于MB输入时,估计误差较小。总体而言,结果表明,考虑流动状态依赖的损失机制可增强压力降估计,且足够的狭窄喉部采样对MRI基于的流量率和压力降估计至关重要。此外,基于峰值速度的MB压力降估计对像素大小的敏感性较低。

英文摘要:

Accurate non-invasive estimation of trans-stenotic pressure gradients remains a challenge. In clinical practice, pressure gradients are often estimated from velocity measurements using Bernoulli-based formulas, but these simplified relations do not explicitly account for how pressure losses change with the flow regime. Here, we introduce a modified Bernoulli (MB) formulation that incorporates regime-dependent pressure losses through a Reynolds-number-dependent loss coefficient. Steady in-vitro experiments were performed in an idealized stenosis model over physiologically relevant flow rates (0.65-3.9 L/min), combining direct pressure measurements with ultrasound imaging velocimetry and phase-contrast magnetic resonance imaging (PC-MRI) to measure velocities. The MB model was calibrated from the measured pressure drops and then evaluated against the simplified Bernoulli (SB) and extended Bernoulli (EB) formulations. Over the tested flow regime, MB agreed best with the measurements. SB and EB showed larger biases, with errors of roughly 10-55% (SB) and -15 to 25% (EB), and overestimated the pressure drop in the clinically relevant range. We additionally quantified the effect of PC-MRI in-plane pixel size on MRI-based pressure estimates. Coarse sampling of the stenosis throat led to systematic underestimation of flow rate and bulk velocity and, consequently, of the MB-predicted pressure drop. In contrast, the peak throat velocity was substantially less sensitive to pixel size, resulting in smaller estimation errors when used as input for the MB. Overall, the results demonstrate that accounting for flow-regime-dependent loss mechanisms enhances pressure drop estimation, and that sufficient sampling of the stenotic throat is crucial for MRI-based flow rate and pressure drop estimation. In addition, peak-velocity-based MB pressure drop estimations are less sensitive to pixel size.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑