arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1901.09351cs.CV

Automated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging Study

Biomedical Image Analysis Group, Department of Computing, Imperial College London(帝国理工学院计算机系生物医学图像分析组);Division of Brain Sciences, Dept. of Medicine, Imperial College London(帝国理工学院医学部脑科学系);GlaxoSmithKline Research and Development(葛兰素史克研发部);William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London(伦敦玛丽女王大学威廉·哈维研究所(NIHR巴茨生物医学研究中心));Barts Heart Centre, Barts Health NHS Trust(巴茨健康国民医疗服务信托基金巴茨心脏中心);Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford(牛津大学拉德克利夫医学部心血管医学系);Department of Radiology, Severance Hospital, Yonsei University College of Medicine(延世大学医学院塞弗伦斯医院放射科);UK Dementia Research Institute, Imperial College London(帝国理工学院英国痴呆症研究所)
Robert Robinson, Vanya V. Valindria, Wenjia Bai, Ozan Oktay, Bernhard Kainz, Hideaki Suzuki, Mihir M. Sanghvi, Nay Aung, Jos$é$ Miguel Paiva, Filip Zemrak, Kenn… 展开作者

Robert Robinson, Vanya V. Valindria, Wenjia Bai, Ozan Oktay, Bernhard Kainz, Hideaki Suzuki, Mihir M. Sanghvi, Nay Aung, Jos$é$ Miguel Paiva, Filip Zemrak, Kenneth Fung, Elena Lukaschuk, Aaron M. Lee, Valentina Carapella, Young Jin Kim, Stefan K. Piechnik, Stefan Neubauer, Steffen E. Petersen, Chris Page, Paul M. Matthews, Daniel Rueckert, Ben Glocker

英文摘要:

Background: The trend towards large-scale studies including population imaging poses new challenges in terms of quality control (QC). This is a particular issue when automatic processing tools, e.g. image segmentation methods, are employed to derive quantitative measures or biomarkers for later analyses. Manual inspection and visual QC of each segmentation isn't feasible at large scale. However, it's important to be able to automatically detect when a segmentation method fails so as to avoid inclusion of wrong measurements into subsequent analyses which could lead to incorrect conclusions. Methods: To overcome this challenge, we explore an approach for predicting segmentation quality based on Reverse Classification Accuracy, which enables us to discriminate between successful and failed segmentations on a per-cases basis. We validate this approach on a new, large-scale manually-annotated set of 4,800 cardiac magnetic resonance scans. We then apply our method to a large cohort of 7,250 cardiac MRI on which we have performed manual QC. Results: We report results used for predicting segmentation quality metrics including Dice Similarity Coefficient (DSC) and surface-distance measures. As initial validation, we present data for 400 scans demonstrating 99% accuracy for classifying low and high quality segmentations using predicted DSC scores. As further validation we show high correlation between real and predicted scores and 95% classification accuracy on 4,800 scans for which manual segmentations were available. We mimic real-world application of the method on 7,250 cardiac MRI where we show good agreement between predicted quality metrics and manual visual QC scores. Conclusions: We show that RCA has the potential for accurate and fully automatic segmentation QC on a per-case basis in the context of large-scale population imaging as in the UK Biobank Imaging Study.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑