Learning-Based Quality Control for Cardiac MR Images
Imperial College London(帝国理工学院);UK Dementia Research Institute(英国痴呆症研究所);MRC London Institute of Medical Sciences(医学研究理事会伦敦医学科学研究所)
Giacomo Tarroni, Ozan Oktay, Wenjia Bai, Andreas Schuh, Hideaki Suzuki, Jonathan Passerat-Palmbach, Antonio de Marvao, Declan P. O'Regan, Stuart Cook, Ben Glock… 展开作者
Giacomo Tarroni, Ozan Oktay, Wenjia Bai, Andreas Schuh, Hideaki Suzuki, Jonathan Passerat-Palmbach, Antonio de Marvao, Declan P. O'Regan, Stuart Cook, Ben Glocker, Paul M. Matthews, Daniel Rueckert
The effectiveness of a cardiovascular magnetic resonance (CMR) scan depends on the ability of the operator to correctly tune the acquisition parameters to the subject being scanned and on the potential occurrence of imaging artefacts such as cardiac and respiratory motion. In the clinical practice, a quality control step is performed by visual assessment of the acquired images: however, this procedure is strongly operator-dependent, cumbersome and sometimes incompatible with the time constraints in clinical settings and large-scale studies. We propose a fast, fully-automated, learning-based quality control pipeline for CMR images, specifically for short-axis image stacks. Our pipeline performs three important quality checks: 1) heart coverage estimation, 2) inter-slice motion detection, 3) image contrast estimation in the cardiac region. The pipeline uses a hybrid decision forest method - integrating both regression and structured classification models - to extract landmarks as well as probabilistic segmentation maps from both long- and short-axis images as a basis to perform the quality checks. The technique was tested on up to 3000 cases from the UK Biobank as well as on 100 cases from the UK Digital Heart Project, and validated against manual annotations and visual inspections performed by expert interpreters. The results show the capability of the proposed pipeline to correctly detect incomplete or corrupted scans (e.g. on UK Biobank, sensitivity and specificity respectively 88% and 99% for heart coverage estimation, 85% and 95% for motion detection), allowing their exclusion from the analysed dataset or the triggering of a new acquisition.
School of Biomedical Engineering & Imaging Sciences, King’s College London, UK(伦敦国王学院生物医学工程与成像科学学院);Technical University of Munich, Germany(慕尼黑工业大学);Biomedical Image Analysis Group, Imperial College London, UK(帝国理工学院生物医学图像分析组);Department of Adult and Paediatric Cardiology, Guy’s and St Thomas’ NHS Foundation Trust, London, UK(盖伊和圣托马斯国民健康服务信托基金会成人及儿科心脏病科);Coimbra Institute for Biomedical Imaging and Translational Research, University of Coimbra, Portugal(科英布拉大学科英布拉生物医学成像与转化研究学院);Helmholtz Center Munich, Germany(慕尼黑亥姆霍兹中心)
Cine cardiac MRI is routinely acquired for the assessment of cardiac health, but the imaging process is slow and typically requires several breath-holds to acquire sufficient k-space profiles to ensure good image quality. Several undersampling-based reconstruction techniques have been proposed during the last decades to speed up cine cardiac MRI acquisition. However, the undersampling factor is commonly fixed to conservative values before acquisition to ensure diagnostic image quality, potentially leading to unnecessarily long scan times. In this paper, we propose an end-to-end quality-aware c…
In recent years, convolutional neural networks have demonstrated promising performance in a variety of medical image segmentation tasks. However, when a trained segmentation model is deployed into the real clinical world, the model may not perform optimally. A major challenge is the potential poor-quality segmentations generated due to degraded image quality or domain shift issues. There is a timely need to develop an automated quality control method that can detect poor segmentations and feedback to clinicians. Here we propose a novel deep generative model-based framework for quality control …
Deep learning methods have reached state-of-the-art performance in cardiac image segmentation. Currently, the main bottleneck towards their effective translation into clinics requires assuring continuous high model performance and segmentation results. In this work, we present a novel learning framework to monitor the performance of heart segmentation models in the absence of ground truth. Formulated as an anomaly detection problem, the monitoring framework allows deriving surrogate quality measures for a segmentation and allows flagging suspicious results. We propose two different types of qu…
Biomedical Image Analysis Group, Department of Computing, Imperial College London(帝国理工学院计算机系生物医学图像分析组);Division of Brain Sciences, Dept. of Medicine, Imperial College London(帝国理工学院医学部脑科学系);GlaxoSmithKline Research and Development(葛兰素史克研发部);William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London(伦敦玛丽女王大学威廉·哈维研究所(NIHR巴茨生物医学研究中心));Barts Heart Centre, Barts Health NHS Trust(巴茨健康国民医疗服务信托基金巴茨心脏中心);Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford(牛津大学拉德克利夫医学部心血管医学系);Department of Radiology, Severance Hospital, Yonsei University College of Medicine(延世大学医学院塞弗伦斯医院放射科);UK Dementia Research Institute, Imperial College London(帝国理工学院英国痴呆症研究所)
Background: The trend towards large-scale studies including population imaging poses new challenges in terms of quality control (QC). This is a particular issue when automatic processing tools, e.g. image segmentation methods, are employed to derive quantitative measures or biomarkers for later analyses. Manual inspection and visual QC of each segmentation isn't feasible at large scale. However, it's important to be able to automatically detect when a segmentation method fails so as to avoid inclusion of wrong measurements into subsequent analyses which could lead to incorrect conclusions. Met…
Guy’s and St Thomas’ Hospital NHS Foundation Trust(盖伊和圣托马斯医院NHS基金会信托);King’s College London(伦敦国王学院);Imperial College London(帝国理工学院)
Quality assessment of medical images is essential for complete automation of image processing pipelines. For large population studies such as the UK Biobank, artefacts such as those caused by heart motion are problematic and manual identification is tedious and time-consuming. Therefore, there is an urgent need for automatic image quality assessment techniques. In this paper, we propose a method to automatically detect the presence of motion-related artefacts in cardiac magnetic resonance (CMR) images. As this is a highly imbalanced classification problem (due to the high number of good qualit…
Continuous protocols for cardiac magnetic resonance imaging enable sampling of the cardiac anatomy simultaneously resolved into cardiac phases. To avoid respiration artifacts, associated motion during the scan has to be compensated for during reconstruction. In this paper, we propose a sampling adaption to acquire 2-D respiration information during a continuous scan. Further, we develop a pipeline to extract the different respiration states from the acquired signals, which are used to reconstruct data from one respiration phase. Our results show the benefit of the proposed workflow on the imag…
GE Global Research Center(GE全球研究中心);Technische Universität München(慕尼黑工业大学);INSERM(法国国家健康与医学研究院);Université de Lorraine(洛林大学);GE Healthcare(GE医疗)
To develop an efficient motion-compensated reconstruction technique for free-breathing cardiac magnetic resonance imaging (MRI) that allows high-quality images to be reconstructed from multiple undersampled single-shot acquisitions. The proposed method is a joint image reconstruction and motion correction method consisting of several steps, including a non-rigid motion extraction and a motion-compensated reconstruction. The reconstruction includes a denoising with the Beltrami regularization, which offers an ideal compromise between feature preservation and staircasing reduction. Results were …
4D Flow is an MRI sequence which allows acquisition of 3D images of the heart. The data is typically acquired volumetrically, so it must be reformatted to generate cardiac long axis and short axis views for diagnostic interpretation. These views may be generated by placing 6 landmarks: the left and right ventricle apex, and the aortic, mitral, pulmonary, and tricuspid valves. In this paper, we propose an automatic method to localize landmarks in order to compute the cardiac views. Our approach consists of first calculating a bounding box that tightly crops the heart, followed by a landmark loc…
King's College London(伦敦国王学院);Guy's and St Thomas' Hospital NHS Foundation Trust(盖伊和圣托马斯国民保健服务基金会信托医院);Imperial College London(帝国理工学院)
Good quality of medical images is a prerequisite for the success of subsequent image analysis pipelines. Quality assessment of medical images is therefore an essential activity and for large population studies such as the UK Biobank (UKBB), manual identification of artefacts such as those caused by unanticipated motion is tedious and time-consuming. Therefore, there is an urgent need for automatic image quality assessment techniques. In this paper, we propose a method to automatically detect the presence of motion-related artefacts in cardiac magnetic resonance (CMR) cine images. We compare tw…
Cine cardiac magnetic resonance (CMR) imaging is considered the gold standard for cardiac function evaluation. However, cine CMR acquisition is inherently slow and in recent decades considerable effort has been put into accelerating scan times without compromising image quality or the accuracy of derived results. In this paper, we present a fully-automated, quality-controlled integrated framework for reconstruction, segmentation and downstream analysis of undersampled cine CMR data. The framework enables active acquisition of radial k-space data, in which acquisition can be stopped as soon as …
Fraunhofer Institute for Telecommunications–Heinrich Hertz Institute(弗劳恩霍夫电信研究所-海因里希·赫兹研究所);Technische Universität Berlin(柏林工业大学);Experimental and Clinical Research Center(实验与临床研究中心);Charité Medical Faculty(夏里特医学院);Max-Delbrueck Center for Molecular Medicine(马克斯·德尔布吕克分子医学中心);HELIOS Klinikum Berlin Buch(柏林布赫赫利俄斯医院);Physikalisch-Technische Bundesanstalt (PTB)(德国联邦物理技术研究院(PTB));King’s College London(伦敦国王学院)
High-resolution three-dimensional (3D) cardiovascular magnetic resonance (CMR) is a valuable medical imaging technique, but its widespread application in clinical practice is hampered by long acquisition times. Here we present a novel compressed sensing (CS) reconstruction approach using shearlets as a sparsifying transform allowing for fast 3D CMR (3DShearCS). Shearlets are mathematically optimal for a simplified model of natural images and have been proven to be more efficient than classical systems such as wavelets. Data is acquired with a 3D Radial Phase Encoding (RPE) trajectory and an it…
Bursa Technical University(布尔萨技术大学);Imperial College London(伦敦帝国学院)
Recently, deep networks have shown impressive performance for the segmentation of cardiac Magnetic Resonance Imaging (MRI) images. However, their achievement is proving slow to transition to widespread use in medical clinics because of robustness issues leading to low trust of clinicians to their results. Predicting run-time quality of segmentation masks can be useful to warn clinicians against poor results. Despite its importance, there are few studies on this problem. To address this gap, we propose a quality control method based on the agreement across decoders of a multi-view network, TMS-…
Dublin City University(都柏林城市大学);University College Dublin(都柏林大学学院)
Methods that are resilient to artifacts in the cardiac magnetic resonance imaging (MRI) while performing ventricle segmentation, are crucial for ensuring quality in structural and functional analysis of those tissues. While there has been significant efforts on improving the quality of the algorithms, few works have tackled the harm that the artifacts generate in the predictions. In this work, we study fine tuning of pretrained networks to improve the resilience of previous methods to these artifacts. In our proposed method, we adopted the extensive usage of data augmentations that mimic those…
Technical University of Munich(慕尼黑工业大学);Southern University of Science and Technology(南方科技大学)
Tackling domain shifts in multi-centre and multi-vendor data sets remains challenging for cardiac image segmentation. In this paper, we propose a generalisable segmentation framework for cardiac image segmentation in which multi-centre, multi-vendor, multi-disease datasets are involved. A generative adversarial networks with an attention loss was proposed to translate the images from existing source domains to a target domain, thus to generate good-quality synthetic cardiac structure and enlarge the training set. A stack of data augmentation techniques was further used to simulate real-world t…
University of Oxford(牛津大学);National Institutes of Health(美国国立卫生研究院);Tufts University School of Medicine(塔夫茨大学医学院)
Feature tracking Cardiac Magnetic Resonance (CMR) has recently emerged as an area of interest for quantification of regional cardiac function from balanced, steady state free precession (SSFP) cine sequences. However, currently available techniques lack full automation, limiting reproducibility. We propose a fully automated technique whereby a CMR image sequence is first segmented with a deep, fully convolutional neural network (CNN) architecture, and quadratic basis splines are fitted simultaneously across all cardiac frames using least squares optimization. Experiments are performed using da…
Istanbul Technical University(伊斯坦布尔理工大学);King’s College London(伦敦国王学院)
Segmenting anatomical structures in medical images has been successfully addressed with deep learning methods for a range of applications. However, this success is heavily dependent on the quality of the image that is being segmented. A commonly neglected point in the medical image analysis community is the vast amount of clinical images that have severe image artefacts due to organ motion, movement of the patient and/or image acquisition related issues. In this paper, we discuss the implications of image motion artefacts on cardiac MR segmentation and compare a variety of approaches for joint…
Memorial Sloan Kettering Cancer Center(纪念斯隆-凯特琳癌症中心);Sun Yat-sen University(中山大学);SUNY Upstate Medical University(纽约州立大学上州医科大学);Old Dominion University(老道明大学)
Our aim was to enhance visual quality and quantitative accuracy of dynamic positron emission tomography (PET)uptake images by improved image reconstruction, using sophisticated sparse penalty models that incorporate both 2D spatial+1D temporal (3DT) information. We developed two new 3DT PET reconstruction algorithms, incorporating different temporal and spatial penalties based on discrete cosine transform (DCT)w/ patches, and tensor nuclear norm (TNN) w/ patches, and compared to frame-by-frame methods; conventional 2D ordered subsets expectation maximization (OSEM) w/ post-filtering and 2D-DCT…
King's College London(伦敦国王学院);St Thomas' Hospital NHS Foundation Trust(圣托马斯医院NHS基金会信托);Philips Research(飞利浦研究院);Sanofi R&D(赛诺菲研发中心)
The availability of large scale databases containing imaging and non-imaging data, such as the UK Biobank, represents an opportunity to improve our understanding of healthy and diseased bodily function. Cardiac motion atlases provide a space of reference in which the motion fields of a cohort of subjects can be directly compared. In this work, a cardiac motion atlas is built from cine MR data from the UK Biobank (~ 6000 subjects). Two automated quality control strategies are proposed to reject subjects with insufficient image quality. Based on the atlas, three dimensionality reduction algorith…
Sano Centre for Computational Medicine(萨诺计算医学中心);Informatics Institute, University of Amsterdam(阿姆斯特丹大学信息学研究所);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院)
Cardiac Magnetic Resonance Imaging is commonly used for the assessment of the cardiac anatomy and function. The delineations of left and right ventricle blood pools and left ventricular myocardium are important for the diagnosis of cardiac diseases. Unfortunately, the movement of a patient during the CMR acquisition procedure may result in motion artifacts appearing in the final image. Such artifacts decrease the diagnostic quality of CMR images and force redoing of the procedure. In this paper, we present a Multi-task Swin UNEt TRansformer network for simultaneous solving of two tasks in the …
Cardiac Magnetic Resonance Imaging (MRI) plays an important role in the analysis of cardiac function. However, the acquisition is often accompanied by motion artefacts because of the difficulty of breath-hold, especially for acute symptoms patients. Therefore, it is essential to assess the quality of cardiac MRI for further analysis. Time-consuming manual-based classification is not conducive to the construction of an end-to-end computer aided diagnostic system. To overcome this problem, an automatic cardiac MRI quality estimation framework using ensemble and transfer learning is proposed in t…
Fudan University(复旦大学);Imperial College London(帝国理工学院);University of Oxford(牛津大学);Zhongshan Hospital Affiliated to Fudan University(复旦大学附属中山医院)
The quality of cardiac magnetic resonance (CMR) imaging is susceptible to respiratory motion artifacts. The model robustness of automated segmentation techniques in face of real-world respiratory motion artifacts is unclear. This manuscript describes the design of extreme cardiac MRI analysis challenge under respiratory motion (CMRxMotion Challenge). The challenge aims to establish a public benchmark dataset to assess the effects of respiratory motion on image quality and examine the robustness of segmentation models. The challenge recruited 40 healthy volunteers to perform different breath-ho…
Temporally Consistent and Controllable Video Generation of 2D Cine CMR via Latent Space Motion Modeling
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences(苏州生物医学工程与技术研究所,中国科学院);SyCoIA, IMT Mines Ales(SyCoIA,IMT Mines Ales)
Using Foundation Models as Pseudo-Label Generators for Pre-Clinical 4D Cardiac CT Segmentation
Yale University(耶鲁大学);University of Pennsylvania(宾夕法尼亚大学);Washington University School of Medicine in St Louis(华盛顿大学圣路易斯医学学院);University of South Carolina School of Medicine(南卡罗来纳大学医学院);University of Colorado Boulder(科罗拉多大学波德分校)
Reconstruction of Cardiac Cine MRI Using Motion-Guided Deformable Alignment and Multi-Resolution Fusion
School of Health Science and Engineering, University of Shanghai for Science and Technology(上海理工大学健康科学与工程学院);ToolSensing Technologies Co., Ltd(拓深科技有限公司);School of Medical Instruments, Shanghai University of Medicine and Health Sciences(上海健康医学院医疗器械学院);Shanghai Key Laboratory of Multidimensional Information Processing, School of Communication & Electronic Engineering, East China Normal University(华东师范大学通信与电子工程学院多维信息处理上海重点实验室)
Eindhoven University of Technology(埃因霍温理工大学);Philips Research(飞利浦研究院)
Fast and accurate catheter detection in cardiac catheterization using harmless 3D ultrasound (US) can improve the efficiency and outcome of the intervention. However, the low image quality of US requires extra training for sonographers to localize the catheter. In this paper, we propose a catheter detection method based on a pre-trained VGG network, which exploits 3D information through re-organized cross-sections to segment the catheter by a shared fully convolutional network (FCN), which is called a Direction-Fused FCN (DF-FCN). Based on the segmented image of DF-FCN, the catheter can be loc…
Accurate cardiac computing, analysis and modeling from multi-modality images are important for the diagnosis and treatment of cardiac disease. Late gadolinium enhancement magnetic resonance imaging (LGE MRI) is a promising technique to visualize and quantify myocardial infarction (MI) and atrial scars. Automating quantification of MI and atrial scars can be challenging due to the low image quality and complex enhancement patterns of LGE MRI. Moreover, compared with the other sequences LGE MRIs with gold standard labels are particularly limited, which represents another obstacle for developing …
Imperial College London(帝国理工学院);University of Edinburgh(爱丁堡大学);Technical University of Munich(慕尼黑工业大学)
Artificial intelligence (AI) and Machine Learning (ML) have shown great potential in improving the medical imaging workflow, from image acquisition and reconstruction to disease diagnosis and treatment. Particularly, in recent years, there has been a significant growth in the use of AI and ML algorithms, especially Deep Learning (DL) based methods, for medical image reconstruction. DL techniques have shown to be competitive and often superior over conventional reconstruction methods in terms of both reconstruction quality and computational efficiency. The use of DL-based image reconstruction a…
UPCMR: A Universal Prompt-guided Model for Random Sampling Cardiac MRI Reconstruction
Leiden University Medical Center(莱顿大学医学中心);Cardiologs;Philips(飞利浦);Eindhoven University of Technology(埃因霍温理工大学);Philips Innovative Technologies(飞利浦创新技术)
University of Edinburgh(爱丁堡大学);Canon Medical Research Europe(佳能医疗欧洲研究中心);The Alan Turing Institute(艾伦·图灵研究所)
Acquiring annotated data at scale with rare diseases or conditions remains a challenge. It would be extremely useful to have a method that controllably synthesizes images that can correct such underrepresentation. Assuming a proper latent representation, the idea of a "latent vector arithmetic" could offer the means of achieving such synthesis. A proper representation must encode the fidelity of the input data, preserve invariance and equivariance, and permit arithmetic operations. Motivated by the ability to disentangle images into spatial anatomy (tensor) factors and accompanying imaging (ve…
DECADE: A Temporally-Consistent Unsupervised Diffusion Model for Enhanced Rb-82 Dynamic Cardiac PET Image Denoising
Yale University(耶鲁大学);Yale School of Medicine(耶鲁医学院);Siemens Medical Solutions USA, Inc.(西门子医疗解决方案美国公司);Inselspital, Bern University Hospital(伯尔尼大学医院Inselspital);University of Bern(伯尔尼大学);Department of Biomedical Engineering(生物医学工程系);Department of Radiology and Biomedical Imaging(放射科和生物医学成像系);Department of Medicine (Cardiology)(医学系(心脏病学))
Columbia University(哥伦比亚大学);Stevens Institute of Technology(史蒂文斯理工学院);Imperial College London(帝国理工学院);Institut Polytechnique de Paris(巴黎理工学院)
Automatically identifying the structural substrates underlying cardiac abnormalities can potentially provide real-time guidance for interventional procedures. With the knowledge of cardiac tissue substrates, the treatment of complex arrhythmias such as atrial fibrillation and ventricular tachycardia can be further optimized by detecting arrhythmia substrates to target for treatment (i.e., adipose) and identifying critical structures to avoid. Optical coherence tomography (OCT) is a real-time imaging modality that aids in addressing this need. Existing approaches for cardiac image analysis main…
Cardiac Magnetic Resonance Imaging (CMR) is widely used since it can illustrate the structure and function of heart in a non-invasive and painless way. However, it is time-consuming and high-cost to acquire the high-quality scans due to the hardware limitation. To this end, we propose a novel end-to-end trainable network to solve CMR video super-resolution problem without the hardware upgrade and the scanning protocol modifications. We incorporate the cardiac knowledge into our model to assist in utilizing the temporal information. Specifically, we formulate the cardiac knowledge as the period…
Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg(生物医学工程人工智能系,埃尔朗根-纽伦堡弗里德里希-亚历山大大学);Department of Biomedical Engineering, The Ohio State University(生物医学工程系,俄亥俄州立大学);Research & Clinical Translation, Magnetic Resonance, Siemens Healthineers AG(研究与临床转化,磁共振,西门子医疗有限公司);Division of Cardiovascular Medicine, The Ohio State University(心血管医学系,俄亥俄州立大学)
CMRxRecon: An open cardiac MRI dataset for the competition of accelerated image reconstruction
Fudan University(复旦大学);The Hong Kong Polytechnic University(香港理工大学);Imperial College London(帝国理工学院);Xiamen University(厦门大学);Shanghai Jiao Tong University School of Medicine(上海交通大学医学院)
Guy’s and St Thomas’ Hospital NHS Foundation Trust(盖伊和圣托马斯医院NHS基金会信托);King’s College London(伦敦国王学院);Imperial College London(帝国理工学院)
In fully sampled cardiac MR (CMR) acquisitions, motion can lead to corruption of k-space lines, which can result in artefacts in the reconstructed images. In this paper, we propose a method to automatically detect and correct motion-related artefacts in CMR acquisitions during reconstruction from k-space data. Our correction method is inspired by work on undersampled CMR reconstruction, and uses deep learning to optimize a data-consistency term for under-sampled k-space reconstruction. Our main methodological contribution is the addition of a detection network to classify motion-corrupted k-sp…
In cases of pressure or volume overload, probing cardiac function may be difficult because of the interactions between shape and deformations.In this work, we use the LDDMM framework and parallel transport to estimate and reorient deformations of the right ventricle. We then propose a normalization procedure for the amplitude of the deformation, and a second-order spline model to represent the full cardiac contraction. The method is applied to 3D meshes of the right ventricle extracted from echocardiographic sequences of 314 patients divided into three disease categories and a control group. W…
EchoFlow: A Foundation Model for Cardiac Ultrasound Image and Video Generation
Imperial College London(帝国理工学院);University of Birmingham(伯明翰大学);Ultromics Ltd.(奥特罗米克斯有限公司);University of Oxford(牛津大学);Friedrich-Alexander-Universität Erlangen-Nürnberg(埃尔朗根-纽伦堡弗里德里希-亚历山大大学)
Department of Bioengineering, Imperial College London(帝国理工学院生物工程系);Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital(皇家布里托尼医院心血管磁共振单位);National Heart and Lung Institute, Imperial College London(帝国理工学院国家心脏和肺研究所)
Enhancing Implicit Neural Representations with Image Feature Embedding for Unsupervised Cardiac Cine MRI Reconstruction
Division of Image Processing, Department of Radiology, Leiden University Medical Center(莱顿大学医学中心放射科图像处理部);C.J. Gorter Center, Department of Radiology, Leiden University Medical Center(莱顿大学医学中心放射科C.J. 戈特中心);Cardio Vascular Imaging Group, Department of Radiology, Leiden University Medical Center(莱顿大学医学中心放射科心血管成像组);Philips Innovative Technologies(飞利浦创新技术公司)
From Raw Segmentations to Simulation-Ready Cardiac Meshes: An Automated Framework for Anatomical Reconstruction and Virtual Cohort Generation
Gran Sasso Science Institute (GSSI)(大萨索科学研究所);European Hospital(欧洲医院);University of Edinburgh(爱丁堡大学);Physics of Fluids Group, University of Twente(特温特大学流体物理小组);INFN–Laboratori Nazionali del Gran Sasso(意大利国家核物理研究所大萨索国家实验室)
Direct Cardiac Segmentation from Undersampled K-space Using Transformers
School of Computation, Information and Technology, Technical University Munich(计算、信息与技术学院,技术大学慕尼黑);Klinikum Rechts der Isar, Technical University Munich(技术大学慕尼黑医院);Munich Center for Machine Learning, Technical University Munich(慕尼黑机器学习中心,技术大学慕尼黑);Department of Computing, Imperial College London(计算系,帝国理工学院伦敦)
Eindhoven University of Technology(埃因霍温理工大学);Philips Research Laboratories(飞利浦研究院);Philips Healthcare(飞利浦医疗)
We propose a hybrid controllable image generation method to synthesize anatomically meaningful 3D+t labeled Cardiac Magnetic Resonance (CMR) images. Our hybrid method takes the mechanistic 4D eXtended CArdiac Torso (XCAT) heart model as the anatomical ground truth and synthesizes CMR images via a data-driven Generative Adversarial Network (GAN). We employ the state-of-the-art SPatially Adaptive De-normalization (SPADE) technique for conditional image synthesis to preserve the semantic spatial information of ground truth anatomy. Using the parameterized motion model of the XCAT heart, we genera…
Faculty of Electrical & Computer Engineering, Technion - IIT(以色列理工学院电气与计算机工程学院);Faculty of Biomedical Engineering, Technion - IIT(以色列理工学院生物医学工程学院);The May-Blum-Dahl MRI Research Center, Faculty of Biomedical Engineering, Technion - IIT(以色列理工学院生物医学工程学院梅-布-达尔磁共振成像研究中心);Bnai Zion Medical Center(巴奈锡安医疗中心)
Klinikum Rechts der Isar, Technical University of Munich(慕尼黑工业大学伊萨尔河右岸医院);Imperial College London(伦敦帝国理工学院);University Hospital of Tübingen(图宾根大学医院)
Motion-compensated MR reconstruction (MCMR) is a powerful concept with considerable potential, consisting of two coupled sub-problems: Motion estimation, assuming a known image, and image reconstruction, assuming known motion. In this work, we propose a learning-based self-supervised framework for MCMR, to efficiently deal with non-rigid motion corruption in cardiac MR imaging. Contrary to conventional MCMR methods in which the motion is estimated prior to reconstruction and remains unchanged during the iterative optimization process, we introduce a dynamic motion estimation process and embed …
Imperial College London(伦敦帝国理工学院);Royal Brompton and Harefield hospital(皇家布朗普顿与哈雷菲尔德医院);Technische Universität München (TUM)(慕尼黑工业大学(TUM))
Diffusion Tensor Cardiac Magnetic Resonance (DT-CMR) enables us to probe the microstructural arrangement of cardiomyocytes within the myocardium in vivo and non-invasively, which no other imaging modality allows. This innovative technology could revolutionise the ability to perform cardiac clinical diagnosis, risk stratification, prognosis and therapy follow-up. However, DT-CMR is currently inefficient with over six minutes needed to acquire a single 2D static image. Therefore, DT-CMR is currently confined to research but not used clinically. We propose to reduce the number of repetitions need…