对在欠采样传感器下光电声成像中共轭方法的评估

Evaluation of Adjoint Methods in Photoacoustic Tomography with Under-Sampled Sensors

The University of Tokyo(东京大学);Bogazici University(博阿齐希大学);Hokkaido University(北海道大学);Stanford University School of Medicine(斯坦福大学医学院)

Hongxiang Lin, Takashi Azuma, Mehmet Burcin Unlu, Shu Takagi

AI总结:

本文探讨了在欠采样传感器条件下,共轭方法在光电声成像中的图像质量和对比度性能,提出了改进的截断反投影方法以提升成像质量。

摘要:

光电声成像(PAT)可以重建在人类乳腺皮下微血管中作为瞬时声源的光吸收分布。PAT中的共轭方法,通常为时间反向(TR)和反投影(BP),是通过波传播从传感器位置将时间反向的声信号重新聚焦到源上。TR和BP在接收到的信号处理上有所不同,但在连续采样于二维闭合圆形传感器阵列时,它们是等价的。本文分析了在香农采样定理意义下的欠采样传感器下的图像质量。我们分别研究了TR和BP在单个源-传感器对配置和频域中的分辨率和对比度。通过Hankel的渐近展开到成像函数的积分项,我们的主要贡献是证明TR和BP在对比度和分辨率上分别具有更好的性能。我们还显示TR的积分项包含额外的旁瓣,会降低轴向分辨率,而BP的积分项则具有相对较小的振幅。此外,如果使用更多传感器收集接收到的信号,可以提高全方位分辨率。然而,对于欠采样传感器,我们提出了截断反投影(TBP)方法,通过去除接收到的信号中的高频成分来增强BP的对比度。我们对从OA-Breast数据库提取的二维投影假人模型进行了数值实验。实验验证了我们的理论,并显示所提出的TBP在欠采样传感器下具有更好的全方位分辨率和对比度,优于TR和BP。

英文摘要:

Photo-Acoustic Tomography (PAT) can reconstruct a distribution of optical absorbers acting as instantaneous sound sources in subcutaneous microvasculature of a human breast. Adjoint methods for PAT, typically Time-Reversal (TR) and Back-Projection (BP), are ways to refocus time-reversed acoustic signals on sources by wave propagation from the position of sensors. TR and BP have different treatments for received signals, but they are equivalent under continuously sampling on a closed circular sensor array in two dimensions. Here, we analyze image quality with discrete under-sampled sensors in the sense of the Shannon sampling theorem. We investigate resolution and contrast of TR and BP, respectively in one source-sensor pair configuration and the frequency domain. With Hankel's asymptotic expansion to the integrands of imaging functions, our main contribution is to demonstrate that TR and BP have better performance on contrast and resolution, respectively. We also show that the integrand of TR includes additional side lobes which degrade axial resolution whereas that of BP conversely has relatively small amplitudes. Moreover, omnidirectional resolution is improved if more sensors are employed to collect the received signals. Nevertheless, for the under-sampled sensors, we propose the Truncated Back-Projection (TBP) method to enhance the contrast of BP using removing higher frequency components in the received signals. We conduct numerical experiments on the two-dimensional projected phantom model extracted from OA-Breast Database. The experiments verify our theories and show that the proposed TBP possesses better omnidirectional resolution as well as contrast compared with TR and BP with under-sampled sensors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑