The increasing demand for Gas Electron Multiplier (GEM) foils has been driven by their application in many current and proposed high-energy physics experiments. Micropack, a Bengaluru-based company, has established and commercialized GEM foils for the first time in India. Micropack used the double-mask etching technique to successfully produce 10 cm $\times$ 10 cm GEM foil. In this paper, we report on the development as well as the geometrical and electrical properties of these foils, including the size uniformity of the holes and leakage current measurements. Our characterization studies show that the foils are of good quality and satisfy all the necessary quality control criteria.
Many experiments are currently using or proposing to use large area GEM foils in their detectors, which is creating a need for commercially available GEM foils. Currently CERN is the only main distributor of large GEM foils, however with the growing interest in GEM technology keeping up with the increasing demand for GEMs will be difficult. Thus the commercialization of GEMs up to 50 $\times$ 50 cm$^2$ has been established by Tech-Etch Inc. of Plymouth, MA, USA using the single-mask technique. The electrical performance and optical quality of the single-mask GEM foils have been found to be on …
The Gas Electron Multiplier (GEM) detectors has been utilized for various applications due to their excellent spatial resolution, high rate capabilities and flexibility in design. The GEM detectors stand as a promising device to be used in nuclear and particle physics experiments. Many future experiments and upgrades are looking forward to use this technology leading to high demand of GEM foils. Until now, CERN is the only reliable manufacturer and distributor of GEM foils, but with technology transfer, few other industries across the globe have started manufacturing these foils employing the …
The Gas Electron Multiplier (GEM) foil is an amplification stage that has been introduced to overcome the problem of discharges observed in gaseous detectors. There are two major production techniques of GEM foils: double-mask and single-mask etching. Despite being an effective method, an asymmetry is observed between the top and bottom diameters of GEM holes in single mask compared to double mask. In this paper we describe extensive simulations and experimental measurements to study this hole asymmetry and its effect on the performance of GEM based detectors. The experimental data is collecte…
Many experiments are currently using or proposing to use large area GEM foils in their detectors, which is creating a need for commercially available GEM foils. Currently CERN is the only main distributor of GEM foils, however with the growing interest in GEM technology keeping up with the increasing demand for GEM foils will be difficult. Thus the commercialization of GEM foils has been established by Tech-Etch Inc. of Plymouth, MA, USA using the single-mask technique, which is capable of producing GEM foils over a meter long. To date Tech-Etch has successfully manufactured 10 $\times$ 10 cm$…
A single-mask Gas Electron Multiplier (GEM) technique overcomes the cumbersome practice of alignment of two masks and allows the production of foils with very large area as needed for the CMS muon forward region upgrade. However, the holes obtained with refinements in the single-mask technique are asymmetrically bi-conical in shape compared to symmetrically bi-conical holes of double-mask technology. The hole geometry and their uniformity define the performance of the detectors which are constructed with such GEM foils. To evaluate the effect of this asymmetry, the foils have been characterize…
An analysis software was developed for the high aspect ratio optical scanning system in the Detec- tor Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standard GEM foils scanned with the optical scanning system. The measurement uncertainty of the diameter of the GEM holes and the pitch of the hole pattern was found to be 0.5 μm and 0.3 μm, respectively. Th…
Many experiments are currently using or proposing to use large area GEM foils in their detectors, which is creating a need for commercially available GEM foils. Currently CERN is the only main distributor of large GEM foils, however with the growing interest in GEM technology keeping up with the increasing demand for GEMs will be difficult. We present here an update on the assembly and testing of triple-GEM tracking detectors utilizing single-masked $40 \times 40$ cm$^2$ commercial GEM foils produced by Tech-Etch. The triple-GEM detectors will allow us to characterize the overall quality of th…
The Gas Electron Multiplier (GEM) is a new age detector, which can handle the high flux of particles. The GEM foil, which is constructed using 50$μ$m highly insulating foil (Kapton/Apical) coated with 5$μ$m layers of copper, on both sides, with a network of specifically shaped holes is the major component of these detectors. The European Center for Nuclear Research (CERN) has been the sole supplier of the GEM foils until recently when a few other companies started manufacturing GEM foils under the transfer of technology (TOT) agrement from CERN. Techtra is one such company in Europe which gain…
The ALICE (A Large Ion Collider Experiment) experiment at the Large Hadron Collider (LHC) at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC) of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second long shutdown (LS2) the LHC will run at substantially higher luminosities. To be able to increase the data acquisition rate by a factor of 100, the ALICE TPC experiment has to replace the Multi-Wire Pr…
The recently completed Forward GEM Tracker (FGT) of the STAR experiment at RHIC took advantage of commercially produced GEM foils based on double-mask chemical etching techniques. With future experiments proposing detectors that utilize very large-area GEM foils, there is a need for commercially available GEM foils. Double-mask etching techniques pose a clear limitation in the maximum size. In contrast, single-mask techniques developed at CERN would allow one to overcome those limitations. We report on results obtained using 10 $\times$ 10 cm$^2$ and 40$\times$40 cm$^2$ GEM foils produced by T…
With future experiments proposing detectors that utilize very large-area GEM foils, there is a need for commercially available GEM foils. Double-mask etching techniques pose a clear limitation in the maximum size of GEM foils. In contrast, single-mask techniques developed at CERN would allow one to overcome those limitations. However with interest in GEM foils increasing and CERN being the only main distributor, keeping up with the demand for GEM foils will be difficult. Thus the commercialization of GEMs has been established by Tech-Etch of Plymouth, MA, USA using single-mask techniques. We r…
The Gas Electron Multiplier (GEM) technology is based on thin polymer foils cladded with copper on both the sides with a regular matrix of holes. Due to the limited manufacturing capacity of CERN, these GEM foils are now commercially manufactured also by Micropack Pvt. Ltd., a company based in India. In order to gain an insight on the behaviour of detectors built using the foils from Micropack, it is important to study various long and short term effects on these foils due to the applied voltage as well as the flux of the incident particles. In this paper, we report the effect on gain stabilit…
Systematic studies on the GEM foil material are performed to measure the moisture diffusion rate and saturation level. These studies are important because the presence of this compound inside the detector's foil can possibly change its mechanical and electrical properties and, in such a way, the detector performance can be affected. To understand this phenomenon, a model is developed with COMSOL Multhiphysics v. 4.3, which described the adsorption and diffusion within the geometry of GEM foil, the concentration profiles and the time required to saturate the foil. The COMSOL model is verified b…
The planned tracking upgrade of the STAR experiment at RHIC includes a large-area GEM tracker used to determine the charge sign of electrons and positrons produced from W+(-) decays. For such a large-scale project commercial availability of GEM foils is necessary. We report first results obtained with a triple GEM detector using GEM foils produced by Tech-Etch Inc. of Plymouth, MA, USA. Measurements of gain uniformity, long-term stability as well as measurements of the energy resolution for X-Rays are compared to results obtained with an identical detector using GEM foils produced at CERN. A q…
We have produced thick-foil and fine-pitch gas electron multipliers (GEMs) using a laser etching technique. To improve production yield we have employed a new material, Liquid Crystal Polymer, instead of polyimide as an insulator layer. The effective gain of the thick-foil GEM with a hole pitch of 140 um, a hole diameter of 70 um, and a thickness of 100 um reached a value of 10^4 at an applied voltage of 720 V. The measured effective gain of the thick-foil and fine-pitch GEM (80 um pitch, 40 um diameter, and 100 um thick) was similar to that of the thick-foil GEM. The gain stability was measur…
The ALICE experiment at LHC has planned to upgrade the TPC by replacing the MWPC with GEM based detecting elements to restrict the IBF to a tolerable value. However the variation of the gain as a function of physical parameters of industrially produced large size GEM foils is needed to be studied as a part of the QA procedure for the detector. The size of the electron avalanche and consequently the gain for GEM based detectors depend on the electric field distribution inside the holes. Geometry of a hole plays an important role in defining the electric field inside it. In this work we have stu…
We report the status of R&D on large triple-GEM detectors for a forward tracker (FT) in an experiment at a future Electron Ion Collider (EIC) that will improve our understanding of QCD. We have designed a detector prototype specifically targeted for the EIC-FT, which has a trapezoidal shape with 30.1 degrees opening angle. We are investigating different detector assembly techniques and signal readout technologies, but have designed a common GEM foil to minimize NRE cost for foil production. The assembly techniques comprise either a purely mechanical method including foil stretching as pioneere…
Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm x 10 cm and a two-dimensional, laser-etched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab. These detectors used GEM foils produced by Tech-Etch, Inc. They showed an efficiency in excess of 95% and spatial resolution better than 70 um. The influence of the angle of incidence of particles on efficiency and spatial resolution was studied in detail.
The challenging physics program at the International Linear Collider (ILC) poses stringent requirements on the performance of its tracking system. A large volume time projection chamber (TPC) is considered a good candidate for such a tracker. Whereas conventional TPCs used a wired based gas amplification system, a future TPC is likely to make use of micro pattern gas detectors as e. g. gas electron multipliers (GEMs) for gas amplification. This talk gives an overview over recent achievements from the R&D activities to build a TPC with a GEM based gas amplification system. This includes charge …
Fiber Bragg Grating (FBG) sensors have been so far mainly used in high energy physics (HEP) as high precision positioning and re-positioning sensors and as low cost, easy to mount, radiation hard and low space- consuming temperature and humidity devices. FBGs are also commonly used for very precise strain measurements. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide Gas Electron Multiplier (GEM) foils of the GE1/1 chambers of the Compact Muon Solenoid (CMS) experiment at Large Hadron Collider (LHC) of CERN. A network of FBG sensors …
Measurements and numerical simulations on the charge transfer in Gas Electron Multiplier (GEM) foils are presented and their implications for the usage of GEM foils in Time Projection Chambers are discussed. A small test chamber has been constructed and operated with up to three GEM foils. The charge transfer parameters derived from the electrical currents monitored during the irradiation with an Fe-55 source are compared with numerical simulations. The performance in magnetic fields up to 2 T is also investigated.
A simple X-ray imaging system using off-the-shelf electronics and simple reconstruction algorithms aiming a spatial resolution of 1.7 mm ($\sim 3\,\%$ of the detector length) is described in this work. For this, two 100 cm$^2$ Gas Electron Multiplier (GEM) foils with a thickness of 100 μm (2-fold thicker than the standard ones) were immersed in a mixture of argon and carbon dioxide (70:30). The charge readout with 2D position determination was done with resistive charge division. Due to their higher thickness with respect to the standard GEMs, the 100 μm thick GEM foils were found to be less p…
The fast timing MPGD is a micro-pattern gaseous detector conceived for achieving sub-nanosecond time resolution while maintaining the ability to instrument large areas in high-rate environments; applications of such technology are perspected in high-energy physics experiments at future colliders and medical diagnostics with time-of-flight methods. This work shows the systematic studies carried on an FTM prototype on the performance of GEM foils coated with resistive DLC films, whose development is essential for the FTM operation. The resistive foil performance has been tested with several gas …
We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment (ILD-TPC). In addition to the gating function, the gating foil is capable of controlling the average fraction of drift electrons detected after gas amplification. The signal charge width and shape (skewness) for electron-ion pairs created by a pulsed UV laser as a function of the transmission rate of the gating foil can be used to determine the relative vari…
To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|η|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must operate in a challenging environment with expected background particle fluxes up to 150 kHz/cm$^2$. Unlike traditional non-resistive gaseous detectors, the rate capability of such triple-GEM detectors is limited not by space charge effects, but by voltage drops on the chamber electrodes due to avalanche-induced currents flowing through the resistive protection c…
This paper presents an investigation of the discharge propagation (DP) to the readout electrode that occurs with a microsecond time delay after a primary discharge that develops inside a GEM foil hole. A single hole THGEM (THick GEM) foil that enables a controlled discharge position and the induction of primary discharge with an over-voltage in the THGEM foil has been used in the initial DP measurements. In order to justify the use of a custom-made THGEM foil, additional measurements were made with a standard GEM foil. Correlated optical (with an ordinary SLR and a high-speed camera) and elect…
Controlled etching of copper electrodes in Gas Electron Multiplier foils allows a reduction of the material budget by more than a factor of two for a triple-GEM detector. Detectors making use of thinned foils provide performances similar to those obtained with standard devices: a gain above 10^4 for a double-GEM, with energy resolution of 27 % fwhm for 5.9 keV X-rays.
Gated wires are widely used in Time Projection Chamber (TPC) to avoid ion back-flow (IBF) in the drift volume. The anode wires can provide stable gain at high voltage with a long lifetime. However, switching on and off the gated grid (GG) leads to a dead time and also limit the readout efficiency of the TPC. Gas Electron Multiplier (GEM) foil provides a possibility of continuous readout for TPC, which can suppress IBF efficiently while keeping stable gain. A prototype chamber including two layers of GEM foils and anode wires has been built to combine both advantages from GEM and anode wire. Us…
We present design and construction of a large low-mass Triple-GEM detector prototype for forward tracking at a future Electron-Ion Collider. In this environment, multiple scattering of forward and backward tracks must be minimized so that electron tracks can be cleanly matched to calorimeter clusters and so that hadron tracks can efficiently seed RICH ring reconstruction for particle identification. Consequently, the material budget for the forward tracking detectors is critical. The construction of the detector builds on the mechanical foil stretching and assembly technique pioneered by CMS f…
The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future International Linear Collider. In this study, two kinds of prototype GEM detectors have been tested. One has 30x30 cm2 active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap. The other one has two 2x2 cm2 GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. We pre…
The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future International Linear Collider. In this study, two kinds of prototype GEM detectors have been tested. One has 30x30 cm2 active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap. The other one has two 2x2 cm2 GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. We pre…
In this work GEM and single-hole Thick GEM structures, composed of different coating materials, are studied. The used foils incorporate conductive layers made of copper, aluminium, molybdenum, stainless steel, tungsten and tantalum. The main focus of the study is the determination of the material dependence of the formation of electrical discharges in GEM-based detectors. For this task, discharge probability measurements are conducted with several Thick GEM samples using a basic electronics readout chain. In addition to that, optical spectroscopy methods are employed to study the light emitted…
Helmholtz-Institut für Strahlen- und Kernphysik, University of Bonn(波恩大学亥姆霍兹射线与核物理研究所);Forschungs- und Technologiezentrum Detektorphysik, University of Bonn(波恩大学探测器物理研究与技术中心);CERN, Geneva(日内瓦欧洲核子研究中心)
本文介绍了在波恩大学FTD建立10 cm x 10 cm GEM箔片本地生产线,采用双掩模光刻和化学蚀刻工艺,并通过质量控制验证其高性能。
We have developed a gating foil for the time projection chamber envisaged as a central tracker for the international linear collider experiment. It has a structure similar to the Gas Electron Multiplier (GEM) with a higher optical aperture ratio and functions as an ion gate without gas amplification. The transmission rate for electrons was measured in a counting mode for a wide range of the voltages applied across the foil using an $^{55}$Fe source and a laser in the absence of a magnetic field. The blocking power of the foil against positive ions was estimated from the electron transmissions.
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors standing five times higher luminosity with hadron beams, detection of beam particles (flux up to a few hundred of kHz/mm^{2}, 10 times larger than for the present Micromegas detectors) with pixelized read-out in the central part, light and integrated electronics, and improved robustness. Two solutions of reduction of discharge impact have been studied, with Microme…
Non destructive quality control of microstructures at the manufacturing stage is an important issue in the foreseen use of huge numbers of such gaseous detectors in the future high luminosity colliders. In this work we report on the use of the scintillation light emitted by the avalanches in GEM channels for checking defects in the foils. The test system is described and data on the relative efficiency of several gaseous mixtures are presented. The foil images obtained with a low-noise CCD system are analysed and compared with the optical images obtained with an industrial inspection system of…
A Time Projection Chamber (TPC) using micro-pattern gas detectors is planned as the main tracking device for a detector at the next Linear Collider. A novel support structure for Gas Electron Multipliers (GEMs), which minimizes the material and improves the flatness of the foils, has been developed and tested with multiple GEM modules in a large TPC prototype at DESY. Reducing dead material at the GEM module boundaries improves the field homogeneity. In addition, it was shown in simulation that a field shaping ring at the border of the module can improve the charge collection in regions with n…
Future measurements of the flavor-separated spin structure of the proton via parity-violating W boson production at RHIC require an upgrade of the forward tracking system of the STAR detector. This upgrade will allow the reconstruction of the charge sign of electrons and positrons produced from decaying W bosons. A design based on six large area triple GEM disks using GEM foils produced by Tech-Etch Inc. has emerged as a cost-effective solution to provide the necessary tracking precision. We report first results from a beam test of three test detectors using Tech-Etch produced GEM foils and a …
Modern time projection chambers are increasingly based on micro pattern gas detector readout systems. In this paper a self-supporting method used to mount Gas Electron Multiplier foils is presented. It is based on light weight ceramic grids, and promises to cover large readout areas with minimum dead zones and material, while ensuring a flat and mechanically stable mounting. The structure has been tested in a Time Projection Chamber prototype, using cosmic muon tracks. The impact of the mounting structure on the charge measurement, the track reconstruction and the single point resolution is qu…
Gas electron multiplier (GEM) is widely used in modern gas detectors of ionizing radiation in experiments on high-energy physics at accelerators and in other fields of science. Typically the GEM devices are based on a dielectric foil with holes and electrodes on both sides. GEMs made by radiation-hard dielectrics or wide band-gap semiconductors are desirable for some applications. The results of the first tests of the gas electron multiplier made of radiation-hard materials, such as polycrystalline CVD diamond with a thickness of 100 microns is described. Here we report on fabrication of GEM b…
In this paper, a detailed investigation has been carried out to understand the physics behind GEM charging-up and its effects on gain. Experiments have been performed on both double and triple GEM with the help of 55Fe X-ray source and a comparative study of these configurations along with the single GEM results observed in our previous work has been reported. The increase in gain due to polarization of GEM foil dielectric and reduction in gain due to charge accumulation on dielectric are studied for various field configurations and different radiation intensities.
GEM are widely used as amplification stages in gaseous detectors exposed to high rates. The GEM consists of a polyimide foil which is coated by two thin copper layers. Charges collected into the holes or created during the amplification process may adhere to the polyimide part inside the holes. This is often accompanied by a change of the effective gain. The effect is commonly known as the charging-up effect. This work presents a systematic investigation of the effect under well-controlled and monitored conditions for a single standard GEM foil in Ar/CO$_2$ (90/10) gas for varying rates of X-r…
Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are captured in a single 2 um thick Boron-10 converter cathode and secondary Helium and Lithium ions are produced with a combined energy of 2.8 MeV. These ions have sufficient energy to form straight tracks of several mm length. With a time resolving 2-dimensional readout of 400 um pitch in both directions, based on APV25 chips, the ions are tracked and their respe…
Results obtained with a triple GEM detector operated in pure CF4 with and without a reflective CsI photocathode are presented. The detector operates in a stable mode at gains up to 10^4. A deviation from exponential growth starts to develop when the total charge exceeds ~ 4 10^6 e leading to gain saturation when the total charge is ~ 2 10^7 e and making the structure relatively robust against discharges. No aging effects are observed in the GEM foils after a total accumulated charge of ~ 10 mC/cm^2 at the anode. The ion back-flow current to the reflective photocathode is comparable to the elec…
Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future High-Luminosity phase of the Large Hadron Collider (HL-LHC). In a first step, GEM chambers (detectors) will be installed in the innermost muon endcap station in the $1.6<\left|η\right|<2.2$ pseudo-rapidity region, mainly to control level-1 muon trigger rates after the second LHC Long Shutdown. These new chambers will add redundancy to the muon system in the $η$-region wh…
Gas Electron Multipliers (GEMs) can be produced in large foils and molded in different shapes. The possibility to create cylindrical layers has opened the opportunity to use such detector as internal tracker at collider experiments. One crucial item is to have low material budget in the active area, so the supporting structure of anode and cathode must be light. KLOE2 collaboration has built the first Cylindrical GEM detector with honeycomb material with carbon fiber skins produced at high temperature. BESIII is developing an innovative CGEM detector with charge and time readout. Among several…
Time Projection Chamber (TPC) has been chosen as the main tracking system in several high-flux and high repetition rate experiments. These include on-going experiments such as ALICE and future experiments such as PANDA at FAIR and ILC. Different $\mathrm{R}\&\mathrm{D}$ activities were carried out on the adoption of Gas Electron Multiplier (GEM) as the gas amplification stage of the ALICE-TPC upgrade version. The requirement of low ion feedback has been established through these activities. Low ion feedback minimizes distortions due to space charge and maintains the necessary values of detecto…
A Time Projection Chamber (TPC) is a powerful detector for 3-dimensional tracking and particle identification for ultra-high multiplicity events. It is the central tracking device of many experiments, e.g. the ALICE experiment at CERN. The necessity of a switching electrostatic gate, which prevents ions produced in the amplification region o MWPCs from entering the drift volume, however, restricts its application to trigger rates of the order of 1 kHz. Charge amplification by Gas Electron Multiplier (GEM) foils instead of proportional wires offers an intrinsic suppression of the ion backflow, …
MAGIX is a planned experiment that will be implemented at the upcoming accelerator MESA in Mainz. Due to its location in the energy-recovering lane of the accelerator beam-currents up to 1mA with a maximum energy of 105 MeV will be available for precision experiments. MAGIX itself consists of a jet-target and two magnetic spectrometers. Inside the spectrometers GEM-based detectors will be used in the focal plane for track reconstruction. The design goals for the detector modules are a spatial resolution of 50 um, a size of 1.20 m x 0.3 m and a minimal material budget. To accomplish these goals…
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This eliminates the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at wide scattering angles. Besides spherical GEMs, we have developed curved spacers to maintain accurate spacing, and a conical field cage to prevent edge distortion of the radial drift field up to the li…
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consist…
Gas Electron Multipliers have undergone a very consistent development since their invention in 1997. Their production procedures have been tuned in such a way that nowadays it is possible to produce foils with areas of the order of the square meter that can operate at a reasonable gain, uniform over large areas and with a good stability in what concerns electrical discharges. For the third run of LHC, they will be included in the CMS and ALICE experiments after significant upgrades of the detectors, confirming that these structures are suitable for very large experiments. In the special case o…
The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length of 600 mm will be tested inside the FOPI spectrometer at GSI using a carbon or lithium beam at intermediate energies (E = 1-3AGeV). This detector test under realistic experimental conditions should allo…
The STAR experiment at the Relativistic Heavy Ion Collider RHIC studies the new state of matter produced in relativistic heavy ion collisions and the spin structure of the nucleon in collisions of polarized protons. In order to improve the capabilities for heavy flavor measurements and the reconstruction of charged vector bosons an upgrade of the tracking system both in the central and the forward region is pursued. The challenging environments of high track multiplicity in heavy ion collisions and of high luminosity in polarized proton collisions require the use of new technologies. The propo…