PURPOSE: To correct line-to-line delays and phase errors in echo-planar imaging (EPI). THEORY AND METHODS: EPI- trajectory auto-corrected image reconstruction (EPI-TrACR) is an iterative maximum-likelihood technique that exploits data redundancy provided by multiple receive coils between nearby lines of k-space to determine and correct line-to-line trajectory delays and phase errors that cause ghosting artifacts. EPI-TrACR was applied to in vivo data acquired at 7 Tesla across acceleration and multishot factors, and in a dynamic time series. The method was efficiently implemented using a segmented FFT and compared to a conventional calibrated reconstruction. RESULTS: Compared to conventional calibrated reconstructions, EPI-TrACR reduced ghosting up to moderate acceleration factors and across multishot factors. It also maintained low ghosting in a dynamic time series. Averaged over all cases, EPI-TrACR reduced root-mean-square ghosted signal outside the brain by 27% compared to calibrated reconstruction. CONCLUSION: EPI-TrACR is effective in automatically correcting line-to-line delays and phase errors in multishot, accelerated, and dynamic EPI. While the method benefits from additional calibration data, it is not a requirement.
Efficient T2 mapping with Blip-up/down EPI and gSlider-SMS (T2-BUDA-gSlider)
目的:快速获得具有全脑覆盖和高几何保真度的高各向同性分辨率T2图。方法:提出了一种具有广义切片抖动增强分辨率(T2-BUDA-gSlider)的T2向上/向下翻转回波平面成像(EPI)采集。开发了具有多个回波时间(TE)的射频(RF)编码的多板自旋回波EPI采集,以获得高SNR效率和减少的重复时间(TR)。这与使用向上/向下相位编码的交错2次激发EPI采集相结合。将估计的场图与结构化低秩约束结合到联合多激发EPI重建中,以在没有导航的情况下为每个板实现无失真和鲁棒的重建。将Bloch模拟子空间模型集成到gSlider重建中并用于T2定量。结果:在体实验结果表明,该方法估计的T2值与金标准自旋回波采集一致。与参考3D快速自旋回波(FSE)图像相比,由非共振和涡流效应引起的失真被有效地减轻。结论:BUDA-gSlider SE-EPI采集和gSlider子空间联合重建能够在2分钟内以约1 mm 3的各向同性分辨率实现无失真的全脑T2标测,这可以为相关临床和神经科学应用带来显著益处。
University Medical Center Freiburg, Faculty of Medicine, University of Freiburg(弗赖堡大学医学院弗赖堡大学医学中心);University of North Carolina, Chapel Hill(北卡罗来纳大学教堂山分校)
High-resolution diffusion-weighted imaging at 7 Tesla: single-shot readout trajectories and their impact on signal-to-noise ratio, spatial resolution and accuracy
College of Health Science and Environmental Engineering, Shenzhen Technology University(深圳科技大学健康科学与环境工程学院);University Medical Center Göttingen(哥廷根大学医学中心);Guangdong-Hongkong-Macau CNS Regeneration Institute, Key Laboratory of CNS Regeneration (Jinan University)-Ministry of Education, Jinan University(广东-港澳-澳门神经科学再生研究所,神经科学再生重点实验室(暨南大学)-教育部,暨南大学);Department of Radiology, The First Hospital of Tsinghua University(清华大学第一医院放射科);Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University(清华大学生物医学成像研究中心,生物医学工程系,医学院);Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University(教育部生物医学工程重点实验室,生物医学工程与仪器科学学院,浙江大学);Department of Endocrinology and Metabolism, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine(浙江大学医学院邵逸夫医院内分泌科);Lab of Molecular Imaging and Medical Intelligence, Department of Radiology, Longgang Central Hospital of Shenzhen (Shenzhen Clinical Medical College, Guangzhou University of Chinese Medicine(分子成像与医学智能实验室,放射科,深圳龙岗中心医院(深圳临床医学院,广州中医药大学;龙岗临床学院,汕头大学医学院));Longgang Clinical Institute of Shantou University Medical College)