用于无失真dMRI的Blip-Up Blip-Down圆形EPI (BUDA-cEPI)及快速展开深度学习重建
Blip-Up Blip-Down Circular EPI (BUDA-cEPI) for Distortion-Free dMRI with Rapid Unrolled Deep Learning Reconstruction
AI总结:
本研究提出了一种名为BUDA-cEPI RUN-UP的快速展开深度学习重建方法,通过结合离共振和涡流效应及虚拟线圈概念,在保持成像细节的同时将重建时间减少约88倍。
摘要:
目的:我们实现了结合读出和相位部分傅里叶的blip-up, blip-down圆形回波平面成像 (BUDA-cEPI) 序列,以减少离共振效应和T2*模糊。使用S-LORAKS(局部k空间邻域的S基低秩建模)的BUDA-cEPI重建被证明能有效重建高度欠采样的BUDA-cEPI数据,但其计算量很大。因此,我们开发了一种基于机器学习的重建技术,称为“BUDA-cEPI RUN-UP”,以实现快速重建。方法:BUDA-cEPI RUN-UP是一个包含离共振和涡流效应的基于模型的框架,通过仅有六次梯度更新的人工神经网络展开。展开网络在数据一致性(即前向BUDA-cEPI及其伴随)和正则化步骤之间交替,其中U-Net作为正则化项。为处理部分傅里叶效应,重建中还引入了虚拟线圈概念,以有效利用平滑相位先验,并训练其预测由BUDA-cEPI与S-LORAKS获得的真值图像。结果:使用S-LORAKS重建的BUDA-cEPI能够处理离共振、部分傅里叶和残余混叠伪影。然而,重建时间约为每层225秒,这在临床环境中可能不实用。相比之下,提出的BUDA-cEPI RUN-UP产生了与BUDA-cEPI与S-LORAKS相似的结果,检测到的归一化均方根误差小于5%,而重建时间约为3秒。结论:结果表明,与最先进的技术相比,BUDA-cEPI RUN-UP将重建时间减少了约88倍,同时通过DTI应用证明了其能保留成像细节。
英文摘要:
Purpose: We implemented the blip-up, blip-down circular echo planar imaging (BUDA-cEPI) sequence with readout and phase partial Fourier to reduced off-resonance effect and T2* blurring. BUDA-cEPI reconstruction with S-based low-rank modeling of local k-space neighborhoods (S-LORAKS) is shown to be effective at reconstructing the highly under-sampled BUDA-cEPI data, but it is computationally intensive. Thus, we developed an ML-based reconstruction technique termed "BUDA-cEPI RUN-UP" to enable fast reconstruction. Methods: BUDA-cEPI RUN-UP - a model-based framework that incorporates off-resonance and eddy current effects was unrolled through an artificial neural network with only six gradient updates. The unrolled network alternates between data consistency (i.e., forward BUDA-cEPI and its adjoint) and regularization steps where U-Net plays a role as the regularizer. To handle the partial Fourier effect, the virtual coil concept was also incorporated into the reconstruction to effectively take advantage of the smooth phase prior, and trained to predict the ground-truth images obtained by BUDA-cEPI with S-LORAKS. Results: BUDA-cEPI with S-LORAKS reconstruction enabled the management of off-resonance, partial Fourier, and residual aliasing artifacts. However, the reconstruction time is approximately 225 seconds per slice, which may not be practical in a clinical setting. In contrast, the proposed BUDA-cEPI RUN-UP yielded similar results to BUDA-cEPI with S-LORAKS, with less than a 5% normalized root mean square error detected, while the reconstruction time is approximately 3 seconds. Conclusion: BUDA-cEPI RUN-UP was shown to reduce the reconstruction time by ~88x when compared to the state-of-the-art technique, while preserving imaging details as demonstrated through DTI application.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。