arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1701.07338astro-ph.HEastro-ph.IM
收藏

大气refractive index对大范围空气簇射无线电信号的影响

The effect of the atmospheric refractive index on the radio signal of extensive air showers

A. Corstanje, A. Bonardi, S. Buitink, H. Falcke, J. R. Hörandel, P. Mitra, K. Mulrey, A. Nelles, J. P. Rachen, L. Rossetto, P. Schellart, O. Scholten, S. ter Ve… 展开作者

A. Corstanje, A. Bonardi, S. Buitink, H. Falcke, J. R. Hörandel, P. Mitra, K. Mulrey, A. Nelles, J. P. Rachen, L. Rossetto, P. Schellart, O. Scholten, S. ter Veen, S. Thoudam, G. Trinh, T. Winchen

摘要:

为了解释大范围空气簇射的无线电发射测量结果,大气折射率$n$的自然变化引起了一个重要的系统不确定性。在给定的海拔高度,视温度、湿度和气压而定,呼吸活性$N=10^6\, (n-1)$可具有大约$10 \%$的相对变化。应用于$N$的典型校正约为$4\%$。使用CoREAS模拟的无线电发射从空气淋浴,我们已经评估了不同的$N$的淋浴最大值$X_{\rm max}$的深度测量的效果。对于30至80 MHz的观测波段,质子簇射天顶角范围为15至50度的质子簇射,质子活动中$4 \%$的差异导致推断的$X_{\rm max}$的系统误差在3.5至11 $\mathrm{g/cm^2}$之间。在120至250 MHz的较高频率下,偏移范围为10至22 $\mathrm{g/cm^2}$。发现这些偏移与到$X_{\rm max}$的几何距离成比例。我们已经比较的结果,一个简单的模型的基础上切连科夫角。对于120至250 MHz频段,该模型是在定性协议的模拟。在典型情况下,我们发现与CoREAS中的默认抗肿瘤活性治疗相比,$X_{\rm max}$略有降低。虽然这在通常处理的系统不确定性范围内,但考虑到这一点,可以明显提高$X_{\rm max}$测量的准确性。

英文摘要:

For the interpretation of measurements of radio emission from extensive air showers, an important systematic uncertainty arises from natural variations of the atmospheric refractive index $n$. At a given altitude, the refractivity $N=10^6\, (n-1)$ can have relative variations on the order of $10 \%$ depending on temperature, humidity, and air pressure. Typical corrections to be applied to $N$ are about $4\%$. Using CoREAS simulations of radio emission from air showers, we have evaluated the effect of varying $N$ on measurements of the depth of shower maximum $X_{\rm max}$. For an observation band of 30 to 80 MHz, a difference of $4 \%$ in refractivity gives rise to a systematic error in the inferred $X_{\rm max}$ between 3.5 and 11 $\mathrm{g/cm^2}$, for proton showers with zenith angles ranging from 15 to 50 degrees. At higher frequencies, from 120 to 250 MHz, the offset ranges from 10 to 22 $\mathrm{g/cm^2}$. These offsets were found to be proportional to the geometric distance to $X_{\rm max}$. We have compared the results to a simple model based on the Cherenkov angle. For the 120 to 250 MHz band, the model is in qualitative agreement with the simulations. In typical circumstances, we find a slight decrease in $X_{\rm max}$ compared to the default refractivity treatment in CoREAS. While this is within commonly treated systematic uncertainties, accounting for it explicitly improves the accuracy of $X_{\rm max}$ measurements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑