纯CsI晶体的纵向均匀性、时间性能及辐照试验

Longitudinal uniformity, time performance and irradiation test of pure CsI crystals

M. Angelucci, O. Atanova, S. Baccaro, A. Cemmi, M. Cordelli, R. Donghia, S. Giovannella, F. Happacher, S. Miscetti, I. Sarra, S. R. Soleti

摘要:

为了研究BaF 2的替代品,作为Mu 2 e量热计的晶体选择,来自Opto Materials和ISMA生产商的13种纯CsI晶体已经通过确定它们的光产额(LY)和纵向响应均匀性(LRU)进行了表征,当用UV扩展PMT读取时。晶体显示约100 p.e./cm的LY。MeV(~ 150 p.e./ MeV),当用Tyvek包裹并连接到不含(含)光学油脂的PMT时。LRU由平均约为-0.6%/cm的线性斜率很好地表示。光电材料晶体的定时性能,与紫外线扩展MPPC读取,已评估与最小的电离粒子。使用(不使用)光学油脂将光电传感器连接到MPPC时,可实现约330 ps(约440 ps)的时序分辨率。对SICCAS生产的CsI晶体进行了辐照强度的研究。在将其暴露于900 Gy的剂量后,观察到LY降低33%,而LRU保持不变。

英文摘要:

To study an alternative to BaF2, as the crystal choice for the Mu2e calorimeter, thirteen pure CsI crystals from Opto Materials and ISMA producers have been characterized by determining their light yield (LY) and longitudinal response uniformity (LRU), when read with a UV extended PMT. The crystals show a LY of ~ 100 p.e./MeV (~ 150 p.e./MeV) when wrapped with Tyvek and coupled to the PMT without (with) optical grease. The LRU is well represented by a linear slope that is on average around -0.6 %/cm. The timing performances of the Opto Materials crystal, read with a UV extended MPPC, have been evaluated with minimum ionizing particles. A timing resolution of ~ 330 ps (~ 440 ps) is achieved when connecting the photosensor to the MPPC with (without) optical grease. The crystal radiation hardness to a ionization dose has also been studied for one pure CsI crystal from SICCAS. After exposing it to a dose of 900 Gy, a decrease of 33% in the LY is observed while the LRU remains unchanged.