Dmitry A. Pushin, Dusan Sarenac, Dan Hussey, Houxun Miao, Muhammad Arif, David G. Cory, Michael G. Huber, David Jacobson, Jacob LaManna, Joseph D. Parker, Taken… 展开作者
Dmitry A. Pushin, Dusan Sarenac, Dan Hussey, Houxun Miao, Muhammad Arif, David G. Cory, Michael G. Huber, David Jacobson, Jacob LaManna, Joseph D. Parker, Taken Shinohara, Wakana Ueno, Han Wen
We demonstrate a two phase-grating, multi-beam neutron interferometer by using a modified Ronchi setup in a far-field regime. The functionality of the interferometer is based on the universal \moire effect that was recently implemented for X-ray phase-contrast imaging in the far-field regime. Interference fringes were achieved with monochromatic, bichromatic, and polychromatic neutron beams; for both continuous and pulsed beams. This far-field neutron interferometry allows for the utilization of the full neutron flux for precise measurements of potential gradients, and expands neutron phase-contrast imaging techniques to more intense polycromatic neutron beams.
We describe an all-fiber nonlinear interferometer based on four-wave mixing in highly nonlinear fiber. Our configuration realizes phase-sensitive interference with 97% peak visibility and >90% visibility over a broad 554 GHz optical band. By comparing the output noise power to the shot-noise level, we confirm noise cancellation at dark interference fringes, as required for quantum-enhanced sensitivity. Our device extends nonlinear interferometry to the important platform of highly nonlinear optical fiber, and could find application in a variety of fiber-based sensors.
An optical etalon illuminated by a white light source provides a broadband comb-like spectrum that can be employed as a calibration source for astronomical spectrographs in radial velocity (RV) surveys for extrasolar planets. For this application the frequency stability of the etalon is critical, as its transmission spectrum is susceptible to frequency fluctuations due to changes in cavity temperature, optical power and input polarization. In this paper we present a laser frequency comb measurement technique to characterize the frequency stability of a custom-designed fiber Fabry-Perot interfe…
A concept to measure the neutron electric charge is presented which employs a precision Talbot-Lau interferometer in a high-intensity pulsed neutron beam. It is demonstrated that the sensitivity for a neutron charge measurement can be improved by up to two orders of magnitude compared to the current best direct experimental limit.
In order to expand the astrophysical reach of gravitational wave detectors, several interferometer topologies have been proposed to evade the thermodynamic and quantum mechanical limits in future detectors. In this work, we make a systematic comparison among them by considering their sensitivities and complexities. We numerically optimize their sensitivities by introducing a cost function that tries to maximize the broadband improvement over the sensitivity of current detectors. We find that frequency-dependent squeezed-light injection with a hundred-meter scale filter cavity yields a good bro…
We report the first successful operation of a neutron interferometer having a separate beam recombining crystal. We achieved this result at the neutron interferometry setup S18 at the ILL in Grenoble by a collaboration between TU Wien, ILL Grenoble and INRIM Torino. While previous interferometers were machined out of a single crystal block, we managed to align two crystals on nanoradian and picometer scales, as required to obtain neutron interference. As a decisive proof of principle demonstration, it opens the door to a new generation of neutron interferometers and exciting applications.
We demonstrate a three phase-grating neutron interferometer as a robust candidate for large area interferometry applications and characterization of materials. This novel far-field moire technique allows for broad wavelength acceptance and relaxed requirements related to fabrication and alignment, circumventing the main obstacles associated with perfect crystal neutron interferometry. Interference fringes were observed with a total interferometer length of four meters, and the effects of an aluminum 6061 alloy sample on the coherence of the system was examined. Experiments to measure the autoc…
We provide the first demonstration that a neutron far-field interferometer can be employed to measure the microstructure of a sample. The interferometer is based on the moiré pattern of two phase modulating gratings which was previously realized in hard x-ray and visible light experiments. The autocorrelation length of this interferometer, and hence the microstructure length scale that is probed, is proportional to the grating spacing and the neutron wavelength, and can be varied over several orders of magnitude for one pair of gratings. We compare our measurements of the change in visibility …
Construction of silicon neutron interferometers requires a perfect crystal silicon ingot (5 cm to 30 cm long) be machined such that Bragg diffracting "blades" protrude from a common base. Leaving the interferometer blades connected to the same base preserves Bragg plane alignment, but if the interferometer contains crystallographic misalignments of greater than about 10 nrad between the blades, interference fringe visibility begins to suffer. Additionally, the parallelism, thickness, and distance between the blades must be machined to micron tolerances. Traditionally, interferometers do not ex…
Neutron interferometry enables precision measurements that are typically operated within elaborate, multi-layered facilities which provide substantial shielding from environmental noise. These facilities are necessary to maintain the coherence requirements in a perfect crystal neutron interferometer which is extremely sensitive to local environmental conditions such as temperature gradients across the interferometer, external vibrations, and acoustic waves. The ease of operation and breadth of applications of perfect crystal neutron interferometry would greatly benefit from a mode of operation…
The use of transparent test/source masses can benefit future measurements of Newton's gravitational constant $G$. Such transparent test mass materials can enable nondestructive, quantitative internal density gradient measurements using optical interferometry and allow in-situ optical metrology methods to be realized for the critical distance measurements often needed in a $G$ apparatus. To confirm the sensitivity of such optical interferometry measurements to internal density gradients it is desirable to conduct a check with a totally independent technique. We present an upper bound on possibl…
Following significant instrument upgrades and parallel methodological developments over the past decade, the TOSCA neutron spectrometer at the ISIS Pulsed Neutron & Muon Source in the United Kingdom has developed a rich and growing scientific community spanning a broad range of non-traditional areas of neutron science, including chemical catalysis, gas adsorption & storage, and new materials for energy and sustainability. High-pressure science, however, has seen little to no representation to date owing to previous limitations in capability. Herein, we explore for the first time the viability …
The recent development of phase-grating moiré neutron interferometry promises a wide range of impactful experiments from dark-field imaging of material microstructure to precise measurements of fundamental constants. However, the contrast of 3 % obtained using this moiré interferometer was well below the theoretical prediction of 30 % using ideal gratings. It is suspected that non-ideal aspects of the phase-gratings was a leading contributor to this deficiency and that phase-gratings needed to be quantitatively assessed and optimized. Here we characterize neutron diffraction from phase-grating…
Laser phase noise remains a limiting factor in many experimental settings, including metrology, time-keeping, as well as quantum optics. Hitherto this issue was addressed at low frequencies, ranging from well below 1 Hz to maximally 100 kHz. However, a wide range of experiments, such as, e.g., those involving nanomechanical membrane resonators, are highly sensitive to noise at higher frequencies in the range of 100 kHz to 10 MHz, such as nanomechanical membrane resonators. Here we employ a fiber-loop delay line interferometer optimized to cancel laser phase noise at frequencies around 1.5 MHz.…
The binary neutron star coalescence GW170817 was observed by gravitational wave detectors during the inspiral phase but sensitivity in the 1-5 kHz band was insufficient to observe the expected nuclear matter signature of the merger itself, and the process of black hole formation. This provides strong motivation for improving 1--5 kHz sensitivity which is currently limited by photon shot noise. Resonant enhancement by signal recycling normally improves the signal to noise ratio at the expense of bandwidth. The concept of optomechanical white light signal recycling (WLSR) has been proposed, but …