arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1602.05154physics.ins-dethep-ex
收藏

用于低温应用的MCP基光电探测器

MCP-based Photodetectors for Cryogenic Applications

Ranjan Dharmapalan, Anil Mane, Karen Byrum, Marcel Demarteau, Jeffrey Elam, Edward May, Robert Wagner, Dean Walters, Lei Xia, Junqi Xie, Huyue Zhao, J. Wang

摘要:

基于阿贡MCP的光电探测器是大面积皮秒光电探测器(LAPPD)项目的一个分支,其中6 cm x 6 cm尺寸的探测器由阿贡国家实验室制造。我们已经成功地建立和测试了我们的第一个探测器的皮秒定时和几毫米的空间分辨率。我们讨论我们的努力,定制这些探测器在低温环境中运行。最初的计划是在液态氩中运行。我们还在探索减轻波长偏移要求的方法,并开发裸MCP光电探测器,以在气态低温环境中工作。

英文摘要:

The Argonne MCP-based photo detector is an offshoot of the Large Area Pico-second Photo Detector (LAPPD) project, wherein 6 cm x 6 cm sized detectors are made at Argonne National Laboratory. We have successfully built and tested our first detectors for pico-second timing and few mm spatial resolution. We discuss our efforts to customize these detectors to operate in a cryogenic environment. Initial plans aim to operate in liquid argon. We are also exploring ways to mitigate wave length shifting requirements and also developing bare-MCP photodetectors to operate in a gaseous cryogenic environment.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑