arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1512.04524physics.ins-dethep-ex
收藏

低质量高效率带电粒子探测器的研制

Development of a low-mass and high-efficiency charged particle detector

D. Naito, Y. Maeda, N. Kawasaki, T. Masuda, H. Nanjo, T. Nomura, M. Sasaki, N. Sasao, S. Seki, K. Shiomi, Y. Tajima

摘要:

我们研制了一种用于稀有衰变$K_L \rightarrow π^0 ν\barν$实验研究的低质量高效率带电粒子探测器。检测器对于将带电粒子背景抑制到标准模型(O(10 $^{-11}$))预测的信号分支比以下的水平是重要的。该探测器由两层3毫米厚的塑料反射器和多像素光子计数器组成。我们制造了计数器,并评估了性能,如光产额,定时分辨率和效率。通过这种设计,我们实现了每层对穿透带电粒子的效率小于$1.5 \times 10^{-5}$,这满足了模拟研究确定的KOTO实验的要求。

英文摘要:

We developed a low-mass and high-efficiency charged particle detector for an experimental study of the rare decay $K_L \rightarrow π^0 ν\barν$. The detector is important to suppress the background with charged particles to the level below the signal branching ratio predicted by the Standard Model (O(10$^{-11}$)). The detector consists of two layers of 3-mm-thick plastic scintillators with wavelength shifting fibers embedded and Multi Pixel Photon Counters for readout. We manufactured the counter and evaluated the performance such as light yield, timing resolution, and efficiency. With this design, we achieved the inefficiency per layer against penetrating charged particles to be less than $1.5 \times 10^{-5}$, which satisfies the requirement of the KOTO experiment determined from simulation studies.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑