基于量子级联laser的超窄线宽和$1\times 10^{-13}$级频率不稳定性中红外测量系统

A quantum cascade laser-based mid-IR frequency metrology system with ultra-narrow linewidth and $1\times 10^{-13}$-level frequency instability

Michael G. Hansen, Evangelos Magoulakis, Qun-Feng Chen, Ingo Ernsting, Stephan Schiller

摘要:

我们展示了一个强大的工具,高分辨率中红外光谱和频率计量与量子级联激光器(QCL)。我们实现了QCL到超低膨胀(ULE)参考腔的频率稳定,通过上转换到近红外光谱范围,在$1\times10^{-13}$的水平。利用频率梳相位稳定到独立的超稳激光器上,测量了QCL相对于氢脉泽的绝对频率,并给出了不稳定性$<1\times10^{-13}$和不准确性$5\times10^{-13}$。QCL线宽被确定为60 Hz,主要由光纤噪声。光纤噪声的主动抑制可能导致低于10 Hz的线宽。

英文摘要:

We demonstrate a powerful tool for high-resolution mid-IR spectroscopy and frequency metrology with quantum cascade lasers (QCLs). We have implemented frequency stabilization of a QCL to an ultra-low expansion (ULE) reference cavity, via upconversion to the near-IR spectral range, at a level of $1\times10^{-13}$. The absolute frequency of the QCL is measured relative to a hydrogen maser, with instability $<1\times10^{-13}$ and inaccuracy $5\times10^{-13}$, using a frequency comb phase-stabilized to an independent ultrastable laser. The QCL linewidth is determined to be 60 Hz, dominated by fiber noise. Active suppression of fiber noise could result in sub-10 Hz linewidth.