arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1407.6438astro-ph.IM
收藏

PRAXIS:低热发射高效率OH抑制光纤光谱仪

PRAXIS: low thermal emission high efficiency OH suppressed fibre spectrograph

Robert Content, Joss Bland-Hawthorn, Simon Ellis, Luke Gers, Roger Haynes, Anthony Horton, Jon Lawrence, Sergio Leon-Saval, Emma Lindley, Seong-Sik Min, Keith S… 展开作者

Robert Content, Joss Bland-Hawthorn, Simon Ellis, Luke Gers, Roger Haynes, Anthony Horton, Jon Lawrence, Sergio Leon-Saval, Emma Lindley, Seong-Sik Min, Keith Shortridge, Nick Staszak, Christopher Trinh, Pascal Xavier, Ross Zhelem

摘要:

PRAXIS是继GNOSIS之后的第二代仪器,GNOSIS是第一台使用光纤布拉格光栅进行OH背景抑制的仪器。布拉格光栅反射NIR OH线,同时对线之间的光透明。这在低分辨率下给出了高得多的信噪比,但通过去除OH线的散射翼,在更高的分辨率下也给出了高得多的信噪比。该规格要求高通量和非常低的热和检测器噪声,使PRAXIS将保持天空噪声限制。光学训练由前置光学器件、IFU、光纤束、布拉格光栅单元、第二光纤束和光谱仪组成。GNOSIS使用了现有的IRIS2光谱仪,而PRAXIS将使用专门为光纤布拉格光栅OH抑制设计的新光谱仪,并针对1470 nm至1700 nm进行了优化(通过改变光栅和重新聚焦,它也可以在1090 nm至1260 nm波段使用)。由于高效率涂层、低入射角下的VPH光栅和低吸收玻璃,这导致显著更高的透射率。探测器噪声也将更低。在整个PRAXIS设计中,沿光路的每一步都要特别小心,以减少热辐射或阻止热辐射泄漏到系统中。这使得摄谱仪的设计具有挑战性,因为实际的限制要求探测器和摄谱仪外壳在环境温度下通过空气物理分离。目前,该仪器采用的是GNOSIS光纤光栅OH抑制单元。我们打算很快使用一种基于多芯光纤布拉格光栅的新OH抑制单元,这将允许增加每根光纤的视场。理论计算表明,使用GNOSIS OH抑制单元,GNOSIS的行间天空背景信噪比增益可高达9,使用多芯光纤OH抑制单元,GNOSIS的行间天空背景信噪比增益可高达17。

英文摘要:

PRAXIS is a second generation instrument that follows on from GNOSIS, which was the first instrument using fibre Bragg gratings for OH background suppression. The Bragg gratings reflect the NIR OH lines while being transparent to light between the lines. This gives a much higher signal-noise ratio at low resolution but also at higher resolutions by removing the scattered wings of the OH lines. The specifications call for high throughput and very low thermal and detector noise so that PRAXIS will remain sky noise limited. The optical train is made of fore-optics, an IFU, a fibre bundle, the Bragg grating unit, a second fibre bundle and a spectrograph. GNOSIS used the pre-existing IRIS2 spectrograph while PRAXIS will use a new spectrograph specifically designed for the fibre Bragg grating OH suppression and optimised for 1470 nm to 1700 nm (it can also be used in the 1090 nm to 1260 nm band by changing the grating and refocussing). This results in a significantly higher transmission due to high efficiency coatings, a VPH grating at low incident angle and low absorption glasses. The detector noise will also be lower. Throughout the PRAXIS design special care was taken at every step along the optical path to reduce thermal emission or stop it leaking into the system. This made the spectrograph design challenging because practical constraints required that the detector and the spectrograph enclosures be physically separate by air at ambient temperature. At present, the instrument uses the GNOSIS fibre Bragg grating OH suppression unit. We intend to soon use a new OH suppression unit based on multicore fibre Bragg gratings which will allow increased field of view per fibre. Theoretical calculations show that the gain in interline sky background signal-noise ratio over GNOSIS may very well be as high as 9 with the GNOSIS OH suppression unit and 17 with the multicore fibre OH suppression unit.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑