用光纤布拉格光栅抑制近红外OH夜空线--第一个结果
Suppression of the near-infrared OH night sky lines with fibre Bragg gratings - first results
摘要:
地面仪器中1 - 1.8微米的背景噪声主要来自羟基分子的大气排放。我们已经建立并委托了一个新的仪器,GNOSIS,它抑制了1.47 - 1.7微米之间的103个OH双峰的约1000倍,分辨率约为10,000。我们目前的第一个结果,从使用IRIS 2光谱仪在AAT的GNOSIS的调试。GNOSIS前置光学器件、光栅单元和中继光学器件的综合吞吐量约为36%,但如果采用更优化的设计,这一数字可以提高到约46%。我们测量的OH线的强抑制,确认OH抑制与光纤布拉格光栅将是一个强大的低分辨率光谱技术。在1.5和1.7微米之间的综合OH抑制背景与使用没有抑制的相同系统的对照光谱相比减少了9倍。低分辨率OH抑制光谱的潜力与示例的观察说明。GNOSIS背景主要由1.67微米以下的探测器暗电流和1.67微米以上的热发射组成。减去这些值后,我们检测到一个未识别的残留线间成分,其值约为860 +/ 210 ph/s/m^2/微米/弧秒^[2]。该分量在抑制和控制光谱中同样明亮。我们已经调查了线间成分的可能来源,但无法区分可能的仪器伪影和固有的大气排放。解决这种发射源对于设计完全优化的OH抑制光谱仪至关重要。下一代OH抑制摄谱仪将专注于解决线间分量的来源,利用FBG馈电的更好优化。我们量化的最佳OH抑制光纤摄谱仪设计的必要改进。
英文摘要:
The background noise between 1 and 1.8 microns in ground-based instruments is dominated by atmospheric emission from hydroxyl molecules. We have built and commissioned a new instrument, GNOSIS, which suppresses 103 OH doublets between 1.47 - 1.7 microns by a factor of ~1000 with a resolving power of ~10,000. We present the first results from the commissioning of GNOSIS using the IRIS2 spectrograph at the AAT. The combined throughput of the GNOSIS fore-optics, grating unit and relay optics is ~36 per cent, but this could be improved to ~46 per cent with a more optimal design. We measure strong suppression of the OH lines, confirming that OH suppression with fibre Bragg gratings will be a powerful technology for low resolution spectroscopy. The integrated OH suppressed background between 1.5 and 1.7 microns is reduced by a factor of 9 compared to a control spectrum using the same system without suppression. The potential of low resolution OH suppressed spectroscopy is illustrated with example observations. The GNOSIS background is dominated by detector dark current below 1.67 microns and by thermal emission above 1.67 microns. After subtracting these we detect an unidentified residual interline component of ~ 860 +/ 210 ph/s/m^2/micron/arcsec^2. This component is equally bright in the suppressed and control spectra. We have investigated the possible source of the interline component, but were unable to discriminate between a possible instrumental artifact and intrinsic atmospheric emission. Resolving the source of this emission is crucial for the design of fully optimised OH suppression spectrographs. The next generation OH suppression spectrograph will be focussed on resolving the source of the interline component, taking advantage of better optimisation for a FBG feed. We quantify the necessary improvements for an optimal OH suppressing fibre spectrograph design.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。