arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 1407.2997astro-ph.IM
收藏

用于TMT的红外成像光谱仪(IRIS):体相位全息光栅性能测试与讨论

The Infrared Imaging Spectrograph (IRIS) for TMT: Volume phase holographic grating performance testing and discussion

Shaojie Chen, Elliot Meyer, Shelley A. Wright, Anna M. Moore, James E. Larkin, Jerome Maire, Etsuko Mieda, Luc Simard

摘要:

光栅效率最大化是第一个光仪器IRIS(红外成像光谱仪)的一个关键目标,目前正在设计的样品的衍射极限的TMT(三十米望远镜)。体积相位全息(VPH)光栅已经显示出提供极高的效率,对于高的线频率接近100%(即,600 ~ 6000 l/mm),已应用于天文摄谱仪。然而,VPH光栅在近红外中较少被利用,特别是对于具有较低线频率的光栅。鉴于其提供高通量和低散射光的潜力,VPH光栅正在探索IRIS作为光谱仪中潜在的色散元件。我们的团队已经从两个不同的供应商采购了近红外光栅。我们有两个光栅的规格需要IRIS目前的设计:1.51-1.82μm(H波段),以产生一个光谱分辨率为4000和1.19- 1.37 μm(J波段),以产生一个光谱分辨率为8000。在H波段R=4000和J波段R=8000时,每个光栅的中心波长分别为1.629μm和1.27μm,槽密度分别为177 l/mm和440 l/mm。在实验室中直接测量了这两种光栅的效率,发现它们的峰值效率都很好,H波段TM和TE模的峰值效率在布拉格角处都达到了88%,而J波段TM模的峰值效率为90.23%,TE模的峰值效率为79.91%。我们确定了偏离布拉格角的效率下降,当偏离布拉格角2.5 °时,H波段的效率下降20-23%,当偏离布拉格角5°时,J波段的效率下降25%-28%。

英文摘要:

Maximizing the grating efficiency is a key goal for the first light instrument IRIS (Infrared Imaging Spectrograph) currently being designed to sample the diffraction limit of the TMT (Thirty Meter Telescope). Volume Phase Holographic (VPH) gratings have been shown to offer extremely high efficiencies that approach 100% for high line frequencies (i.e., 600 to 6000l/mm), which has been applicable for astronomical optical spectrographs. However, VPH gratings have been less exploited in the near-infrared, particularly for gratings that have lower line frequencies. Given their potential to offer high throughputs and low scattered light, VPH gratings are being explored for IRIS as a potential dispersing element in the spectrograph. Our team has procured near-infrared gratings from two separate vendors. We have two gratings with the specifications needed for IRIS current design: 1.51-1.82μm (H-band) to produce a spectral resolution of 4000 and 1.19- 1.37 μm (J-band) to produce a spectral resolution of 8000. The center wavelengths for each grating are 1.629μm and 1.27μm, and the groove densities are 177l/mm and 440l/mm for H-band R=4000 and J-band R=8000, respectively. We directly measure the efficiencies in the lab and find that the peak efficiencies of these two types of gratings are quite good with a peak efficiency of ~88% at the Bragg angle in both TM and TE modes at H-band, and 90.23% in TM mode, 79.91% in TE mode at J-band for the best vendor. We determine the drop in efficiency off the Bragg angle, with a 20-23% decrease in efficiency at H-band when 2.5 degree deviation from the Bragg angle, and 25%-28% decrease at J-band when 5° deviation from the Bragg angle.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑