Xenon purity analysis for EXO-200 via mass spectrometry
A. Dobi, C. Hall, S. Slutsky, Y. -R. Yen, B. Aharmin, M. Auger, P. S. Barbeau, C. Benitez-Medina, M. Breidenbach, B. Cleveland, R. Conley, J. Cook, S. Cook, I. … 展开作者
A. Dobi, C. Hall, S. Slutsky, Y. -R. Yen, B. Aharmin, M. Auger, P. S. Barbeau, C. Benitez-Medina, M. Breidenbach, B. Cleveland, R. Conley, J. Cook, S. Cook, I. Counts, W. Craddock, T. Daniels, C. G. Davis, J. Davis, R. deVoe, M. Dixit, M. J. Dolinski, K. Donato, W. Fairbank, J. Farine, P. Fierlinger, D. Franco, G. Giroux, R. Gornea, K. Graham, G. Gratta, C. Green, C. Hagemann, K. Hall, D. Hallman, C. Hargrove, S. Herrin, M. Hughes, J. Hodgson, F. Juget, A. Karelin, L. J. Kaufman, A. Kuchenkov, K. Kumar, D. S. Leonard, G. Lutter, D. Mackay, R. MacLellan, M. Marino, B. Mong, M. Montero Díez, P. Morgan, A. R. Müller, R. Neilson, A. Odian, K. O'Sullivan, A. Piepke, A. Pocar, C. Y. Prescott, K. Pushkin, A. Rivas, E. Rollin, P. C. Rowson, A. Sabourov, D. Sinclair, K. Skarpaas, V. Stekhanov, V. Strickland, M. Swift, K. Twelker, J. -L. Vuilleumier, J. -M. Vuilleumier, M. Weber, U. Wichoski, J. Wodin, J. D. Wright, L. Yang
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.
In-situ gamma spectrometry measurements of time-dependent Xenon-135 inventory in the TRIGA Mark II reactor Vienna
在这项工作中,它已被证明,依赖于时间的TRIGA马克II反应堆在奥地利维也纳,即使在强背景辐射的存在下,可以通过伽马能谱测量的<$-135库存。它的重点是测量(但不限于)核素氚-135。维也纳TRIGA Mark II反应堆的随时间变化的135堆芯存量是利用停堆后置于热柱上的堆芯燃料元件与位于反应堆贮箱水面上方的探测器系统之间的临时束线测量的。在一周的时间里,从反应堆停堆后的每天下午开始,直到第二天早上,自动记录多个伽马射线光谱。上周末记录了一个测量系列。使用自动峰搜索算法从总共1227个记录的光谱中提取了135个峰,并分析了它们的时间依赖性。尽管停堆后堆芯中存在的背景伽马辐射很大,特别是在较低能量范围内,但可以从存在的大多数光谱中提取位于249.8 keV处的135峰,并可以与理论计算进行比较。
Measurement of the Argon Purity by ICP-MS and Results of the Analysis of the Gas Used for the MicroBooNE Experiment
测量氩的纯度对于所有基于氩的稀有事件研究实验都是至关重要的。质谱法通常用于评估低本底探测器材料样品中的铀和钍污染;然而,这项技术有可能提供目前尚未开发的其他有价值的信息。我们已经表明,通过ICP-MS,可以识别和量化氩气中常见的化学污染物。初步测试是用从FNAL的MicroBooNE实验和LSC的ArDM实验中提取的气体进行的。在前一种情况下,我们证明了相关的氮污染远高于在商业氩气中测量的氮污染。在ArDM中,我们确定并量化了用于科学运行的气体中汞的存在。在这两种情况下,氩气中均存在氪(~ppb)和氙(~ 10 s ppb)。