Annemieke Petrignani, Simon Altevogt, Max H. Berg, Dennis Bing, Henrik Buhr, Chris H. Greene, Manfred Grieser, Jens Hoffmann, Brandon Jordon-Thaden, Viatcheslav Kokoouline, Claude Krantz, Holger Kreckel, Mario B. Mendes, Oldrich Novotny, Steffen Novotny, Dmitry A. Orlov, Roland Repnow, Tobias Sorg, Julia Stuetzel, Andreas Wolf

摘要:

在离子储存环TSR上,分别用22极阱装置和Penning离子源测量了新的高分辨旋转冷态和热态H~(3+)在振动基态的解离复合速率系数。实验结果与理论计算进行了比较,探索的速率系数对离子温度的依赖关系,并研究不同的对称性探测丰富的预测共振谱的贡献。通过碎片成像研究了破碎能量,以获得在不同实验条件下存储的母离子的内部温度。对加热效应进行了系统的实验评估,并结合最近的储存环数据,表明本实验的旋转冷却速率系数测量是在380 ^{+50}_{-130} K下进行的,这是迄今为止在储存环速率系数测量中实现的最低旋转温度。这部分地支持了理论上的建议,即比早期实验中假设的更高的温度是实验和理论速率系数之间的大差距的主要原因。对于旋转热速率系数测量的温度低于3250 K。从这些较高的温度的结果,它被发现,在计算中增加旋转离子温度不能完全关闭之间的差距的理论和实验速率系数。

英文摘要:

New high-resolution dissociative recombination rate coefficients of rotationally cool and hot H3+ in the vibrational ground state have been measured with a 22-pole trap setup and a Penning ion source, respectively, at the ion storage ring TSR. The experimental results are compared with theoretical calculations to explore the dependence of the rate coefficient on ion temperature and to study the contributions of different symmetries to probe the rich predicted resonance spectrum. The break-up energy was investigated by fragment imaging to derive internal temperatures of the stored parent ions under differing experimental conditions. A systematic experimental assessment of heating effects is performed which, together with a survey of other recent storage-ring data, suggests that the present rotationally cool rate-coefficient measurement was performed at 380^{+50}_{-130} K and that this is the lowest rotational temperature so far realized in storage-ring rate-coefficient measurements on H3+. This partially supports the theoretical suggestion that higher temperatures than assumed in earlier experiments are the main cause for the large gap between the experimental and theoretical rate coefficients. For the rotationally hot rate-coefficient measurement a temperature of below 3250K is derived. From these higher-temperature results it is found that increasing the rotational ion temperature in the calculations cannot fully close the gap between the theoretical and experimental rate coefficients.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑