arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 0903.2483astro-ph.IM
收藏

Simbol-X硬X射线聚焦镜:A期研究期间获得的结果

Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study

G. Tagliaferri, S. Basso, G. Borghi, W. Burkert, O. Citterio, M. Civitani, P. Conconi, V. Cotroneo, M. Freyberg, D. Garoli, P. Gorenstein, G. Hartner, V. Mattar… 展开作者

G. Tagliaferri, S. Basso, G. Borghi, W. Burkert, O. Citterio, M. Civitani, P. Conconi, V. Cotroneo, M. Freyberg, D. Garoli, P. Gorenstein, G. Hartner, V. Mattarello, A. Orlandi, G. Pareschi, S. Romaine, D. Spiga, G. Valsecchi, D. Vernani

摘要:

Simbol-X将把掠入射成像推到80 keV,与迄今为止在10 keV以上运行的所有仪器相比,在灵敏度和角分辨率方面都有很大改进。超硬X射线成像能力将由100个电铸镍壳与多层反射涂层的反射镜模块保证。在这里,我们将描述用于制造反射镜模块的技术发展和解决方案,其必须保证半能宽(HEW)在0.5至30 keV范围内优于20弧秒,并且在60 keV下的目标为40弧秒。在2008年底结束的A阶段,我们分别开发了两个、两个和三个壳体的三个工程模型。Simbol-X反射镜开发中最关键的方面是:i)在任务的时间轴内生产100个表面质量非常好的芯轴; ii)复制必须非常薄的外壳(比XMM-Newton薄2倍),并且在高达80 keV时仍具有非常好的图像质量; iii)开发一种集成工艺,使我们能够集成这些非常薄的反射镜,保持其固有的良好图像质量。阶段A研究表明,我们可以制造所需质量的芯轴,并且我们已经开发了有效的集成过程。到目前为止,我们已经生产的炮弹有一个相当好的图像质量,例如HEW <~30弧秒,在30 keV,和有效面积。然而,我们仍然需要做一些改进,以达到要求。我们将简要介绍这些结果,并讨论我们将在B阶段调查的可能改进。

英文摘要:

Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical development and solutions adopted for the fabrication of the mirror module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A, terminated at the end of 2008, we have developed three engineering models with two, two and three shells, respectively. The most critical aspects in the development of the Simbol-X mirrors are i) the production of the 100 mandrels with very good surface quality within the timeline of the mission; ii) the replication of shells that must be very thin (a factor of 2 thinner than those of XMM-Newton) and still have very good image quality up to 80 keV; iii) the development of an integration process that allows us to integrate these very thin mirrors maintaining their intrinsic good image quality. The Phase A study has shown that we can fabricate the mandrels with the needed quality and that we have developed a valid integration process. The shells that we have produced so far have a quite good image quality, e.g. HEW <~30 arcsec at 30 keV, and effective area. However, we still need to make some improvements to reach the requirements. We will briefly present these results and discuss the possible improvements that we will investigate during phase B.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑