There is a growing interest in producing intense, coherent x-ray radiation with an adjustable and arbitrary polarization state. In this paper, we study the crossed undulator scheme (K.-J. Kim, Nucl. Instrum. Methods A {\bf 445}, 329 (2000)) for rapid polarization control in a self-amplified spontaneous emission (SASE) free electron laser (FEL). Because a SASE source is a temporally chaotic light, we perform a statistical analysis on the state of polarization using FEL theory and simulations. We show that by adding a small phase shifter and a short (about 1.3 times the FEL power gain length), $90^\circ$ rotated planar undulator after the main SASE planar undulator, one can obtain circularly polarized light -- with over 80% polarization -- near the FEL saturation.
The magnetic gap of the baseline XFEL undulators can be varied mechanically for wavelength tuning. In particular, the wavelength range 0.1 nm - 0.4 nm can be covered by operating the European XFEL with the SASE2 undulator. The length of the SASE2 undulator (256.2 m) is sufficient to independently generate three pulses of different radiation wavelengths at saturation. Normally, if a SASE FEL operates in saturation, the quality of the electron beam is too bad for generation of SASE radiation in the subsequent part of undulator which is resonant at a few times longer wavelength. The new method of…
The output SASE characteristics of the baseline European XFEL, recently used in the TDRs of scientific instruments and X-ray optics, have been previously optimized assuming uniform undulators without considering the potential of undulator tapering in the SASE regime. Here we demonstrate that the performance of European XFEL sources can be significantly improved without additional hardware. The procedure simply consists in the optimization of the undulator gap configuration for each X-ray beamline. Here we provide a comprehensive description of the soft X-ray photon beam properties as a functio…
We describe statistical and coherence properties of the radiation from x-ray free electron lasers (XFEL) operating in the post-saturation regime. We consider practical case of the SASE3 FEL at the European XFEL. We perform comparison of the main characteristics of the X-ray FEL operating in the post-saturation regime with and without undulator tapering: efficiency, coherence time and degree of transverse coherence.
We demonstrate that the output radiation characteristics of the European XFEL sources at nominal operation point can be easily made significantly better than what is currently reported in the TDRs of scientific instruments and X-ray optics. In fact, the output SASE characteristics of the baseline European XFEL have been previously optimized assuming uniform undulators at a nominal operating point of 5 kA peak current, without considering the potential of udulator tapering in the SASE regime. In order to illustrate this point, we analyze the case of an electron bunch with nominal parameters. Ba…
The purified SASE (pSASE) undulator configuration recently proposed at SLAC promises an increase in the output spectral density of XFELs. In this article we study a straightforward implementation of this configuration for the soft x-ray beamline at the European XFEL. A few undulator cells, resonant at a subharmonic of the FEL radiation, are used in the middle of the exponential regime to amplify the radiation, while simultaneously reducing the FEL bandwidth. Based on start-to-end simulations, we show that with the proposed configuration the spectral density in the photon energy range between 1…
The optical klystron enhancement to self-amplified spontaneous emission (SASE) free electron lasers (FELs) is studied in theory and in simulations. In contrast to a seeded FEL, the optical klystron gain in a SASE FEL is not sensitive to any phase mismatch between the radiation and the microbunched electron beam. The FEL performance with the addition of four optical klystrons located at the undulator long breaks in the Linac Coherent Light Source (LCLS) shows significant improvement if the uncorrelated energy spread at the undulator entrance can be controlled to a very small level. In addition,…
In this paper, the harmonics suppression effect of QPUs in SASE FEL is investigated. The numerical results show that the harmonics power is reduced by using QPUs, but the fundamental radiation power also has a pronounced decrease as the saturation length gets very long. The cases of employing QPUs as parts of undulators are studied. The calculations show that if the fraction of QPUs and their offgap are appropriate in an undulator system, the harmonics radiation could be suppressed remarkably, meanwhile the fundamental saturation length does not increase too much.
Output characteristics of the European XFEL have been previously studied assuming an operation point at 5 kA peak current. In this paper we explore the possibility to go well beyond such nominal peak current level. In order to illustrate the potential of the European XFEL accelerator complex we consider a bunch with 0.25 nC charge, compressed up to a peak current of 45 kA. An advantage of operating at such high peak current is the increase of the x-ray output peak power without any modification to the baseline design. Based on start-to-end simulations, we demonstrate that such high peak curren…
Influence of a linear energy chirp in the electron beam on a SASE FEL operation is studied analytically and numerically using 1-D model. Explicit expressions for Green's functions and for output power of a SASE FEL are obtained for high-gain linear regime in the limits of small and large energy chirp parameter. Saturation length and power versus energy chirp parameter are calculated numerically. It is shown that the effect of linear energy chirp on FEL gain is equivalent to the linear undulator tapering (or linear energy variation along the undulator). A consequence of this fact is a possibili…
XFELs provide X-ray pulses with unprecedented peak brightness and ultrashort duration. They are usually driven by planar undulators, meaning that the output radiation is linearly polarized. For many experimental applications, however, polarization control is critical: besides the ability to produce linearly polarized radiation, one often needs the possibility of generating circularly polarized radiation with a high, stable degree of polarization. This may be achieved by using a first part of the XFEL undulator to produce bunching and then, by propagating the the bunched beam through an "afterb…
Recent theoretical and experimental studies have shown that Self-Amplified Spontaneous Emission Free Electron Laser (SASE FEL) with a planar undulator holds a potential for generation of relatively strong coherent radiation at the third harmonic of the fundamental frequency. Here we present detailed study of the nonlinear harmonic generation in the SASE FEL obtained with time-dependent FEL simulation code. Using similarity techniques we present universal dependencies for temporal, spectral, and statistical properties of the odd harmonics of the radiation from SASE FEL. In particular, we derive…
We discuss the conditions required for an optimal SASE FEL operation when bunch compression techniques are exploited to enhance the bunch peak current. We discuss the case of velocity bunching and magnetic bunch compression. With the reference to the latter technique we provide a quantitative estimate of the amount of laser heater power necessary to suppress the micro-bunching instability without creating any problem to the SASE dynamics
A SASE FEL facility was first proposed in Feasibility Report of the TAC (Turkish Accelerator Center) project in 2000. Conceptual Design Report (CDR) of the project was completed in 2005. Technical Design Report (TDR) studies of TAC were started in 2006 in frame of an inter universities project with support of State Planning Organization (SPO) of Turkey. Main goal of the SASE FEL proposal is to cover VUV and soft X-rays region of the spectrum besides IR-FEL, Bremsstrahlung and Synchrotron Radiation proposals of TAC. Up to now, optimization studies based on a special RF linac or an Energy Recove…
We explore the possibility of operating a SASE FEL with a Storage Ring. We use a semi-analytical model to obtain the evolution inside the undulator by taking into account the interplay on the laser dynamics due to the induced energy spread and to the radiation damping. We obtain the Renieri's limit for the stationary output power and discuss the possibility of including in our model the effect of the beam instabilities.
The existence of a characteristic coherence length in FEL SASE Physics determines the independent lasing of different portions, namely the slices, of the electron bunch. Each slice may be characterized by different phase space properties (not necessarily equal emittances and Twiss coefficients). This fact opens new questions on the concept of beam matching and how the various portions of the beam contribute to the performances of the output radiation, including those associated with the transverse coherence.
An x-ray regenerative amplifier free-electron laser with a step-tapered-undulator
University of Maryland(马里兰大学);NoVa Physical Science and Simulations(诺瓦物理科学与模拟研究所);MESA+ Institute, University of Twente(特温特大学MESA+研究所);Department of Electrical Engineering, University of Maryland(马里兰大学电气工程系)
Newly developed high peak power lasers have opened the possibilities of driving coherent light sources operating with laser plasma accelerated beams and wave undulators. We speculate on the combination of these two concepts and show that the merging of the underlying technologies could lead to new and interesting possibilities to achieve truly compact, coherent radiator devices.
This paper describes a novel single-bunch self-seeding scheme for generating highly monochromatic X-rays from a baseline XFEL undulator. Previous schemes made use of a four-crystal fixed-exit monochromator in Bragg geometry. In such monochromator the X-ray pulse acquires a cm-long path delay, which must be compensated. For a single-bunch self-seeding scheme this requires a long electron beam bypass, implying modifications of the baseline undulator configuration. To avoid this problem, a double bunch self-seeding scheme based on a special photoinjector setup was recently proposed. At variance, …
In this article we derive longitudinal impedance and wake function for an undulator setup with arbitrary undulator parameter, taking into account a finite transverse size of the electron bunch. Earlier studies considered a line density-distribution of electrons instead. We focus our attention on the long-wavelength asymptote (compared with resonance wavelength), at large distance of the electron bunch from the undulator entrance compared to the overtaking length, and for large vacuum-chamber size compared to the typical transverse size of the field. These restrictions define a parameter region…
Simple formulas for optimization of VUV and X-ray SASE FELs are presented. The FEL gain length and the optimal beta-function are explicitly expressed in terms of the electron beam and undulator parameters. The FEL saturation length is estimated taking into account quantum diffusion in the undulator. Examples of the FEL optimization are given. Parameters of a SASE FEL, operating at the Compton wavelength, are suggested.
We describe a free-electron laser (FEL) in the Self Amplified Spontaneous Emission (SASE) regime quantizing the electron motion and taking into account propagation effects. We demonstrate quantum purification of the SASE spectrum, i.e., in a properly defined quantum regime the spiking behavior disappears and the SASE power spectrum becomes very narrow.
In this letter we specify the physical parameters necessary to operate a SASE FEL in the quantum regime with a laser wiggler. We also show that this is more feasible in the quantum regime than in the classical one. Specific examples are given.
We propose a scheme for generation of single 100 GW 300-as pulse in the X-ray free electron laser with the use of a few cycles optical pulse from Ti:sapphire laser system. Femtosecond optical pulse interacts with the electron beam in the two-period undulator resonant to 800 nm wavelength and produces energy modulation within a slice of the electron bunch. Following the energy modulator the electron beam enters the first part of the baseline gap-adjustable X-ray undulator and produces SASE radiation with 100 MW-level power. Due to energy modulation the frequency is correlated to the longitudina…
The possibility of producing highly circularly polarized X-ray radiation, especially in the soft X-ray region, is an important asset at XFELs. However, the baseline of the European XFEL, including the soft X-ray SASE3 line, foresees planar undulators only. The lowest-risk strategy for implementing polarization control at SASE3 involves adding an APPLE II-type undulator at the end of the planar undulator, to exploit the microbunching from the baseline FEL. 5m-long APPLE II undulators are standard devices at synchrotrons. However, the choice of a short helical radiator leads to the problem of ba…
Initial studies of a 2-colour FEL amplifier using one monoenergetic electron beam are presented. The interaction is modelled using the unaveraged, broadband FEL code Puffin. A series of undulator modules are tuned to generate two resonant frequencies along the FEL interaction and a self-consistent 2-colour FEL interaction at widely spaced non-harmonic wavelengths at 1nm and 2.4nm is demonstrated.
This note presents optimization results for an injector with a super-conducting gun for the cw operation of the European XFEL, the corresponding start-to-end simulation calculations for the beam transport to the undulators and SASE calculations of the X-ray intensities for the achievable photon energies. The optimizations for an injector with a super-conducting gun are done mainly for an already experimentally shown accelerating gradient of 40 MV/m. Different working points with respect to transverse emittance and bunch length are chosen to see whether the lower transverse emittance of the lon…
This paper describes an effective frequency doubler scheme for SASE free electron lasers. It consists of an undulator tuned to the first harmonic, a dispersion section, and a tapered undulator tuned to the second harmonic. The first stage is a conventional soft X-ray SASE FEL. Its gain is controlled in such a way that the maximum energy modulation of the electron beam at the exit is about equal to the local energy spread, but still far away from saturation. When the electron bunch passes through the dispersion section this energy modulation leads to effective compression of the particles. Then…
The polarization switch of a free-electron laser (FEL) is of great importance to the user scientific community. In this paper, we investigate the generation of controllable polarization FEL from two well-known approaches for Dalian coherent light source, i.e., crossed planar undulator and elliptical permanent undulator. In order to perform a fair comparative study, a one-dimensional time-dependent FEL code has been developed, in which the imperfection effects of an elliptical permanent undulator are taken into account. Comprehensive simulation results indicate that the residual beam energy chi…
A simple analysis is given for optimum length of undulator in self-seeding free electron laser (FEL). The obtained relations show the correlation between the undulator length and the system parameters. The power required for the seeding in the second part undulator and overall efficiency to monochromatizating the seeding settle on the length of the first part undulator; the magnitude of seeding power dominates the length of the second part undulator; the whole length of the undulators in self-seeding FEL is determined by the overall efficiency to get coherent seed, it is about half as long aga…
The terahertz FEL ferromagnetic undulator has been created. The length of the undulator period is 9cm, number of the periods is 27. By means of selection and redistribution of magnetic elements the spread of amplitudes of the magnetic field was reduced to 7%. Additional windings of magnetic elements were used to compensate for residual spread. Required focusing gradient of magnetic field was obtained as a result of relative displacement of alternating poles with opposite charge of magnetic field along the x axis. Parameters of undulator including focusing properties in the horizontal plane wer…
Various methods have been proposed to condition an electron beam in order to reduce its emittance effect and to improve the short-wavelength free electron laser (FEL) performance. In this paper, we show that beam conditioning does not result in a complete elimination of the emittance effect in an alternating-gradient focusing FEL undulator. Using a one-dimensional model and a three-dimensional simulation code, we derive a criteria for the emittance limitation of a perfectly conditioned beam that depends on the focusing structure.
We study the tapering optimization scheme for a short period, less than two cm, superconducting undulator, and show that it can generate 4 keV X-ray pulses with peak power in excess of 1 terawatt, using LCLS electron beam parameters. We study the effect of undulator module length relative to the FEL gain length for continous and step-wise taper profiles. For the optimal section length of 1.5m we study the evolution of the FEL process for two different superconducting technologies NbTi and Nb3Sn. We discuss the major factors limiting the maximum output power, particle detrapping around the satu…
Baseline design of a typical X-ray FEL undulator assumes a planar configuration which results in a linear polarization of the FEL radiation. However, many experiments at X-ray FEL user facilities would profit from using a circularly polarized radiation. As a cheap upgrade one can consider an installation of a short helical (or cross-planar) afterburner, but then one should have an efficient method to suppress powerful linearly polarized background from the main undulator. In this paper we propose a new method for such a suppression: an application of the reverse taper in the main undulator. We…
We propose a technique for the production of attosecond X-ray pulses which is based on the use of X-ray SASE FEL combined with a femtosecond laser system. A few-cycle optical pulse from a Ti:sapphire laser interacts with the electron beam in a two-period undulator resonant to 800 nm wavelength and produces energy modulation within a slice of the electron bunch. Following the energy modulator the electron beam enters the X-ray undulator and produces SASE radiation. Due to energy modulation the frequency is correlated to the longitudinal position within the few-cycle-driven slice of SASE radiati…
Free-electron lasers (FELs) have been built ranging in wavelength from long-wavelength oscillators using partial wave guiding through ultraviolet through hard x-ray that are either seeded or start from noise (SASE). In addition, FELs that produce different polarizations of the output radiation ranging from linear through elliptic to circular polarization are currently under study. In this paper, we develop a three-dimensional, time-dependent formulation that is capable of modeling this large variety of FEL configurations including different polarizations. We employ a modal expansion for the op…
We discuss the new problems emerging in charged beam transport for SASE FEL dynamics. The optimization of the magnetic transport system for future devices requires new concepts associated with the slice emittance and the slice phase space distribution. We study the problem of electron beam slice matching and guiding in transport devices for SASE FEL emission discussing matching criteria and how the associated design of the electron transport line may affect the FEL output performances. We analyze different matching strategies by studying the relevant effect on the FEL output characteristics.
We describe use of the Advanced Photon Source (APS) rf thermionic gun, alpha magnet beamline, and linac to produce a stable high-brightness beam in excess of 100 amperes peak current with normalized emittance of 10 pi mm-mrad. To obtain peak currents greater than 100 amperes, the rf gun system must be tuned to produce a FWHM bunch length on the order of 350 fs. Bunch lengths this short are measured using coherent transition radiation (CTR) produced when the rf gun beam, accelerated to 40 MeV, strikes a metal foil. The CTR is detected using a Golay detector attached to one arm of a Michelson in…
Phase 1 of the vacuum ultra-violet (VUV) free-electron laser (FEL) at the TESLA Test Facility (TTF) recently concluded operation. It successfully demonstrated the saturation of a SASE FEL in the in the wavelength range of 80-120 nm. We present a posteriori start-to-end numerical simulations of this FEL. These simulations are based on the programs Astra and elegant for the generation and transport of the electron distribution. An independent simulation of the intricate beam dynamics in the magnetic bunch compressor is performed with the program CSRtrack. The SASE FEL process is simulated with t…
A method to achieve High-Brightness Self-Amplified Spontaneous Emission (HB-SASE) in the Free Electron Laser (FEL) is described. The method uses repeated non-equal electron beam delays to de-localise the collective FEL interaction and break the radiation coherence length dependence on the FEL cooperation length. The method requires no external seeding or photon optics and so is applicable at any wavelength or repetition rate. It is demonstrated using linear theory and numerical simulations that the radiation coherence length can be increased by approximately two orders of magnitude over SASE w…
The production of X-ray radiation with a high degree of circular polarization constitutes an important goal at XFEL facilities. A simple scheme to obtain circular polarization control with crossed undulators has been proposed so far. In its simplest configuration the crossed undulators consist of pair of short planar undulators in crossed position separated by an electromagnetic phase shifter. An advantage of this configuration is a fast helicity switching. A drawback is that a high degree of circular polarization (over 90%) can only be achieved for lengths of the insertion devices significant…
In free electron laser facilities, almost every kind of device will generate wakefield when an electron beam passes through it. Most of the wakefields are undesired and have a negative effect on the electron beam, which means a decrease of FEL performance. As for the SXFEL test facility, the sophisticated layout and the cumulative effect of such a long undulator section lead to an obvious wakefield, which is strong enough that can not be ignored. Based on two deflecting cavities at the entrance and the exit of the undulator section with corresponding profile monitors, we measured the wakefield…
Free-electron lasers (FELs) over virtually the entire electromagnetic spectrum from microwaves through ultraviolet through hard x-rays that are either seeded or start from noise. FELs can produce a variety of different optical polarizations of the output radiation ranging from linear through elliptic to circular polarization depending upon the characteristics of the undulators used. For example, x-ray FELs use long undulator lines composed of a series of relatively short undulators. Most such FELs use linearly polarized undulators due to the ease of manufacture and tuning; hence the optical ou…
A model of a Free Electron Laser operating with an elliptically polarised undulator is presented. The equations describing the FEL interaction, including resonant harmonic radiation fields, are averaged over an undulator period and generate a generalised Bessel function scaling factor, similar to that of planar undulator FEL theory. Comparison between simulations of the averaged model with those of an unaveraged model show very good agreement in the linear regime. Two unexpected results were found. Firstly, an increased coupling to harmonics for elliptical rather than planar polarisarised undu…
It is reported that [Z. Huang et al., Phys. Rev. Lett. 109, 204801 (2012)], high-gain free-electron laser (FEL) can be generated by transverse-dispersed electron beams from laser-plasma accelerators (LPAs) using transverse-gradient undulator (TGU) assuming an ideal constant dispersion function without focusing optics. The constant dispersion function keeps electrons beyond the resonant energy bandwidth still being on resonant with the FEL radiation. Instead, in this paper, the case with focusing optics in an LPA-driven FEL using TGU is numerically studied, in which the dispersion function shou…
We describe a future possible upgrade of the European XFEL consisting in the construction of an undulator beamline dedicated to life science experiments. The availability of free undulator tunnels at the European XFEL facility offers a unique opportunity to build a beamline optimized for coherent diffraction imaging of complex molecules, like proteins and other biologically interesting structures. Crucial parameters for such bio-imaging beamline are photon energy range, peak power, and pulse duration. Key component of the setup is the undulator source. The peak power is maximized in the photon…
The problem of an efficiency increase of an FEL amplifier is now of great practical importance. Technique of undulator tapering in the post-saturation regime is used at the existing x-ray FELs LCLS and SACLA, and is planned for use at the European XFEL, Swiss FEL, and PAL XFEL. There are also discussions on the future of high peak and average power FELs for scientific and industrial applications. In this paper we perform detailed analysis of the tapering strategies for high power seeded FEL amplifiers. Application of similarity techniques allows us to derive universal law of the undulator tape…
The single-pulse spectrum of self-amplified spontaneous emission (SASE) free electron lasers (FELs) is characterized by random fluctuations in frequency. The typical spectrum bandwidth for a hard x-ray FEL is in the range of 10-20 eV and is comparable with the distance between energy levels of valence electrons in atoms an molecules. We calculate the rate of transitions in a quantum three-level system with the energy difference of several eV caused by such radiation and show that for x-ray intensities in the range of $10^{20}$ W/cm$^2$ the probability of the transition over the duration of the…
Extremely high beam-to-radiation energy conversion efficiencies can be obtained in a THz FEL using a strongly tapered helical undulator at the zero-slippage resonant condition, where a circular waveguide is used to match the radiation group velocity to the electron beam longitudinal velocity. In this paper we report on the first electro-optic sampling (EOS) based measurements of the broadband THz FEL radiation pulses emitted in this regime. The THz field waveforms are reconstructed in the spatial and temporal domains using multi-shot and single-shot EOS schemes respectively. The measurements a…
Free-electron lasers (FELs) have been designed to operate over virtually the entire electromagnetic spectrum from microwaves through x-rays and in a variety of configurations including amplifiers and oscillators. Oscillators can operate in both the low and high gain regime and are typically used to improve the spatial and temporal coherence of the light generated. We will discuss various FEL oscillators ranging from systems with high-quality resonators combined with low-gain undulators to systems with a low-quality resonator combined with a high-gain undulator line. The FEL gain code MINERVA a…
The most promising way to increase the output power of an X-ray FEL (XFEL) is by tapering the magnetic field of the undulator. Also, significant increase in power is achievable by starting the FEL process from a monochromatic seed rather than from noise. This report proposes to make use of a cascade self-seeding scheme with wake monochromators in a tunable-gap baseline undulator at the European XFEL to create a source capable of delivering coherent radiation of unprecedented characteristics at hard X-ray wavelengths. Compared with SASE X-ray FEL parameters, the radiation from the new source ha…
Self-seeding options for the LCLS baseline were recently investigated using a scheme which relies on a single-crystal monochromator in Bragg-transmission geometry. The LCLS low-charge (0.02 nC) mode of operation was considered in order to demonstrate the feasibility of the proposed scheme. The wakefield effects from the linac and from the undulator vacuum chamber are much reduced at such low charge, and can be ignored. In this paper we extend our previous investigations to the case of the LCLS mode of operation with nominal charge. Based on the LCLS start-to-end simulation for an electron beam…
We show that radiation pulses from an X-ray Free-Electron Laser (XFEL) with a planar undulator, which are mainly polarized in the horizontal direction, exhibit a suppression of the vertical polarization component of the power at least by a factor $λ_w^2/(4 πL_g)^2$, where $λ_w$ is the length of the undulator period and $L_g$ is the FEL field gain length. We illustrate this fact by examining the XFEL operation under the steady state assumption. In our calculations we considered only resonance terms: in fact, non resonance terms are suppressed by a factor $λ_w^3/(4 πL_g)^3$ and can be neglected.…
We recently proposed a basic concept for design and layout of the undulator source for a dedicated bio-imaging beamline at the European XFEL. The goal of the optimized scheme proposed here is to enable experimental simplification and performance improvement. The core of the scheme is composed by soft and hard X-ray self-seeding setups. Based on the use of an improved design for both monochromators it is possible to increase the design electron energy up to 17.5 GeV in photon energy range between 2 keV and 13 keV, which is the most preferable for life science experiments. An advantage of operat…
In some options for circular polarization control at X-ray FELs, a helical radiator is placed a few ten meters distance behind the baseline undulator. If the microbunch structure induced in the baseline (planar) undulator can be preserved, intense coherent radiation is emitted in the helical radiator. The effects of betatron motion on the preservation of micro bunching in such in-line schemes should be accounting for. In this paper we present a comprehensive study of these effects. It is shown that one can work out an analytical expression for the debunching of an electron beam moving in a FOD…
FLASH is the first soft X-ray FEL user facility, routinely providing brilliant photon beams for users since 2005. The second undulator branch of this facility, FLASH2, is gap-tunable which allows to test and use advanced lasing concepts. In particular, we developed a two-color operation mode based on the alternatingly tuned undulator segments (every other segment is tuned to the second wavelength). This scheme is advantageous in comparison with a subsequent generation of two colors in two consecutive sections of the undulator line. First, source positions of the two FEL beams are close to each…
Independently from electron beam based procedures, photon beam based diagnostics is an alternative way for alignment and commissioning of the numerous undulator cells in a high-gain short-wavelength free-electron laser (FEL). In this paper, using the seed laser modulated electron beam and the undulator fine tuning technique, a coherent photon beam based diagnostic was proposed for seeded FEL, and some preliminary experimental results at Shanghai deep ultraviolet FEL test facility were presented. It demonstrates that the spatial distribution of the coherent harmonic radiation from one individua…
The use of existing linacs, and in particular light source injectors, for free-electron laser (FEL) experiments is becoming more common due to the desire to test FELs at ever shorter wavelengths. The high-brightness, high-current beams required by high-gain FELs impose technical specifications that most existing linacs were not designed to meet. Moreover, the need for specialized diagnostics, especially shot-to-shot data acquisition, demands substantial modification and upgrade of conventional linacs. Improvements have been made to the Advanced Photon Source (APS) injector linac in order to pr…