摘要:

在MEGAPIE实验中子与核评估任务组的框架内,我们测量了靶顶部的缓发中子(DN)通量。提出的测量主要是为了辐射防护的目的,因为在目标的顶部的DN通量已被估计为是相同的数量级的瞬发中子通量。考虑到DN预测的强模型依赖性,因此需要测量DN对靶顶部总中子活度的贡献。此外,该测量是对PNPI(Gatchina)在固体铅和铋靶上进行的DN实验的补充。在MEGAPIE的DN测量是在目标的启动阶段进行的。在本文中,我们提出了一个详细的描述的实验装置和一些初步结果的衰变谱。

英文摘要:

In the framework of the Neutronic and Nuclear Assessment Task Group of the MEGAPIE experiment we measured the delayed neutron (DN) flux at the top of the target. The measurement was proposed mainly for radioprotection purposes since the DN flux at the top of the target has been estimated to be of the same order of magnitude as the prompt neutron flux. Given the strong model-dependence of DN predictions, the measurement of DN contribution to the total neutron activity at the top of the target was thus desired. Moreover, this measurement is complementary to the DN experiments performed at PNPI (Gatchina) on solid lead and bismuth targets. The DN measurement at MEGAPIE was performed during the start-up phase of the target. In this paper we present a detailed description of the experimental setup and some preliminary results on decay spectra.