MEGAPIE项目是加速器驱动系统可行性的关键实验之一。在线操作和辐照后分析将为科学界提供有关液体溅射靶在实际辐照条件下行为的独特数据。这种靶的良好的中子学性能对于强中子源是至关重要的,其中延长的液态金属回路需要与被照射的PbBi的缓发中子活性相关的一些专用验证。本文报道了MEGAPIE中子学的实验特性,即靶内的瞬发中子(PN)通量和靶顶的缓发中子(DN)通量。为了测量PN,我们在靶的中心部分建造了一个由8个微型裂变室组成的复合探测器,用于测量绝对中子通量及其空间分布。此外,可以提取作为沿束轴的位置的函数的关于中子能量分布的积分信息,提供对在诸如MCNPX的运输代码中实现的中子产生模型的积分约束。对于DN测量,我们使用标准的3He计数器,并且我们在目标照射的启动阶段期间获取数据,以便在可变束功率下进行充分的统计。给出了PN通量特性的实验结果及其与MCNPX模拟的比较,并对DN衰减时间谱进行了初步分析。

英文摘要:

The MEGAPIE project is one of the key experiments towards the feasibility of Accelerator Driven Systems. On-line operation and post-irradiation analysis will provide the scientific community with unique data on the behavior of a liquid spallation target under realistic irradiation conditions. A good neutronics performance of such a target is of primary importance towards an intense neutron source, where an extended liquid metal loop requires some dedicated verifications related to the delayed neutron activity of the irradiated PbBi. In this paper we report on the experimental characterization of the MEGAPIE neutronics in terms of the prompt neutron (PN) flux inside the target and the delayed neutron (DN) flux on the top of it. For the PN measurements, a complex detector, made of 8 microscopic fission chambers, has been built and installed in the central part of the target to measure the absolute neutron flux and its spatial distribution. Moreover, integral information on the neutron energy distribution as a function of the position along the beam axis could be extracted, providing integral constraints on the neutron production models implemented in transport codes such as MCNPX. For the DN measurement, we used a standard 3He counter and we acquired data during the start-up phase of the target irradiation in order to take sufficient statistics at variable beam power. Experimental results obtained on the PN flux characteristics and their comparison with MCNPX simulations are presented, together with a preliminary analysis of the DN decay time spectrum.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑