A measurement of the absolute neutron beam polarization produced by an optically-pumped 3He spin filter
D. R. Rich, J. D. Bowman, B. E. Crawford, P. P. J. Delheij, M. A. Espy, T. Haseyama, G. Jones, C. D. Keith, J. Knudson, M. B. Leuschner, A. Masaike, Y. Masuda, … 展开作者
D. R. Rich, J. D. Bowman, B. E. Crawford, P. P. J. Delheij, M. A. Espy, T. Haseyama, G. Jones, C. D. Keith, J. Knudson, M. B. Leuschner, A. Masaike, Y. Masuda, Y. Matsuda, S. I. Penttila, V. R. Pomeroy, D. A. Smith, W. M. Snow, S. L. Stephenson, A. K. Thompson, V. Yuan
备注:
35 pages, 11 figures, LaTeX format, submitted to Phys. Rev. A (1999)
The capability of performing accurate measurements of neutron beam polarization opens a number of exciting opportunities in fundamental neutron physics and in neutron scattering. At the LANSCE pulsed neutron source we have measured the neutron beam polarization with absolute accuracy of 0.3% in the neutron energy range from 40 meV to 10 eV using an optically-pumped polarized 3He spin filter and a relative transmission measurement technique. 3He was polarized using the Rb spin-exchange method. We describe the measurement technique, present our results, and discuss some of the systematic effects associated with the method.
Optically pumped atomic magnetometers (OPMs) offer highly sensitive magnetic measurements using compact hardware, offering new possibilities for practical precision sensors. Double-resonance OPM operation is well suited to unshielded magnetometry, due to high sensor dynamic range. However, sensor response is highly anisotropic with variation in the orientation of the magnetic field. We present data quantifying these effects and discuss implications for the design of practical sensors.
We describe a multichannel magnetoencephalography (MEG) system that uses optically pumped magnetometers (OPMs) to sense the magnetic fields of the human brain. The system consists of an array of 20 OPM channels conforming to the human subject's head, a person-sized magnetic shield containing the array and the human subject, a laser system to drive the OPM array, and various control and data acquisitions systems. We conducted two MEG experiments: auditory evoked magnetic field (AEF) and somatosensory evoked magnetic field (SEF), on three healthy male subjects, using both our OPM array and a 306…
An integrated system of hardware and software allowing precise definition of arbitrarily oriented magnetic fields up to |B| = 1 μT within a five-layer mumetal shield is described. The system is calibrated with reference to magnetic resonance observed between Zeeman states of the 6S$_{1/2}$ F = 4 $^{133}$Cs ground state. Magnetic field definition over the full 4π solid angle is demonstrated, with one-sigma tolerances in magnitude, orientation and gradient of δ|B| = 0.94 nT, δθ = 5.9 mrad and δ$\nabla$ B = 13.0 pT/mm, respectively. This field control is used to empirically map Mx magnetometer si…
Room temperature Terahertz stimulated emission and population inversion in optically pumped graphene is reported. We experimentally observe fast relaxation and relatively slow recombination dynamics of photogenerated electrons/holes in an exfoliated graphene on SiO2/Si substrate under pumping with a 1550-nm, 80-fs pulsed fiber laser beam and probing with the corresponding terahertz beam generated by optical rectification in a nonlinear electro optical sensor. The time resolved electric field intensity originating from the coherent terahertz photon emission is electro-optically sampled in an to…
We present a portable optically pumped magnetometer instrument for ultra-sensitive measurements within the Earth's magnetic field. The central part of the system is a sensor head operating a MEMS-based Cs vapor cell in the light-shift dispersed Mz mode. It is connected to a compact, battery-driven electronics module by a flexible cable. We briefly review the working principles of the device and detail on the realization of both, sensor head and electronics. We show shielded and unshielded measurements within a static magnetic field amplitude of 50 uT demonstrating a noise level of the sensor s…
Solid state battery technology is motivated by the desire to deliver flexible power storage in a safe and efficient manner. The increasingly widespread use of batteries from mass-production facilities highlights the need for a rapid and sensitive diagnostic for identifying battery defects. We demonstrate the use of atomic magnetometry to measure the magnetic fields around miniature solid-state battery cells. These fields encode information about battery manufacturing defects, state of charge, impurities, or can provide important insights into ageing processes. Compared with SQUID-based magneto…
We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/Hz$^{1/2}$ at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensat…
Scalar optically-pumped magnetometers (OPMs) are being developed in small packages with high sensitivities. The high common-mode rejection ratio of these sensors allows for detection of very small signals in the presence of large background fields making them ideally suited for brain imaging applications in unshielded environments. Despite a flurry of activity around the topic, questions remain concerning how well a dipolar source can be localized under such conditions, especially when using few sensors. In this paper, we investigate the source localization capabilities using an array of scala…
Phase projection errors in rf-driven optically pumped magnetometers
Institute of Physics Belgrade, University of Belgrade(贝尔格莱德物理研究所,贝尔格莱德大学);Physics Department, University of Fribourg(弗里堡大学物理系);Leibniz Institute of Photonic Technology(莱布尼茨光子技术研究所)
We investigate a search for the oscillating current induced by axion dark matter in an external magnetic field using optically pumped magnetometers (OPMs). This experiment is based upon the LC circuit axion detection concept of Sikivie, Sullivan, and Tanner. The modification of Maxwell's equations caused by the axion-photon coupling results in a minute oscillating magnetic field at the frequency equal to the axion mass in the presence of magnetic field. This induced magnetic field could be searched for using an LC circuit amplifier with an OPM, the most sensitive cryogen-free magnetic-field se…
In this paper, we propose a method to estimate the position, orientation and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer and model these discreetly sampled fields using vector-spherical harmonics (VSH) functions. We then localize and calibrate a sensor by minimizing the sum of squared errors between the model signals and…
We demonstrate an optically pumped $^{87}$Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the $^{87}$Rb ground state energy levels. The magnetometer is operated in the spin-exchange relaxation-free regime where high magnetic field sensitivities can be achieved. This device can be useful in applications requiring array-based magnetometers where radio frequency magnetic fields can induce cross-talk among adjacent sensors or affect the source of the magnetic field being measured.
The authors describe a novel variety of spinning-rotor vacuum gauge in which the rotor is a ${\sim}4.7{\text -}μ$m-diameter silica microsphere, optically levitated. A rotating electrostatic field is used to apply torque to the permanent electric dipole moment of the silica microsphere and control its rotational degrees of freedom. When released from a driving field, the microsphere's angular velocity decays exponentially with a damping time inversely proportional to the residual gas pressure, and dependent on gas composition. The gauge is calibrated by measuring the rotor mass with electrostat…