All-optical atomic magnetometers based on nonlinear magneto-optical rotation with amplitude modulated light
S. Pustelny, A. Wojciechowski, M. Kotyrba, K. Sycza, J. Zachorowski, W. Gawlik, A. Cingoz, N. Leefer, J. M. Higbie, E. Corsini, M. P. Ledbetter, S. M. Rochester… 展开作者
S. Pustelny, A. Wojciechowski, M. Kotyrba, K. Sycza, J. Zachorowski, W. Gawlik, A. Cingoz, N. Leefer, J. M. Higbie, E. Corsini, M. P. Ledbetter, S. M. Rochester, A. O. Sushkov, D. Budker
备注:
8 pages, 6 figures, Submitted to Proc. of SPIE, Proceedings of XIVth International School on Quantum Electronics, Sunny Beach, Bulgaria 2006
We demonstrate a magnetometric technique based on nonlinear magneto-optical rotation using amplitude modulated light. The magnetometers can be operated in either open-loop (typical nonlinear magneto-optical rotation with amplitude-modulated light) or closed-loop (self-oscillating) modes. The latter mode is particularly well suited for conditions where the magnetic field is changing by large amounts over a relatively short timescale.
We present here a new parametric resonance magnetometer scheme based on elliptically polarized pumping light and two radio-frequency fields applied along the two optical pumping directions. At optimum ellipticity and radio-frequency fields amplitudes the three components of the magnetic field are measured with an isotropic sensitivity. Compared to the usual alignment-based parametric resonance magnetometers, the sensitivity is degraded by a factor 2 for two components of the magnetic field but improved by a factor 11 for the third one. This new magnetometer configuration could be particularly …
We demonstrate an optically pumped $^{87}$Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the $^{87}$Rb ground state energy levels. The magnetometer is operated in the spin-exchange relaxation-free regime where high magnetic field sensitivities can be achieved. This device can be useful in applications requiring array-based magnetometers where radio frequency magnetic fields can induce cross-talk among adjacent sensors or affect the source of the magnetic field being measured.
We describe an array of spin-exchange relaxation free optical magnetometers designed for detection of fetal magnetocardiography (fMCG) signals. The individual magnetometers are configured with a small volume with intense optical pumping, surrounded by a large pump-free region. Spin-polarized atoms that diffuse out of the optical pumping region precess in the ambient magnetic field and are detected by a probe laser. Four such magnetometers, at the corners of a 7 cm square, are configured for gradiometry by feeding back the output of one magnetometer to a field coil to null uniform magnetic fiel…
The method of operation of an atomic magnetometer based on coherent population trapping (CPT) without any requirement of radio frequency scanning is demonstrated. Using a hybrid approach comprising of polarization rotation and tailored transmission due to CPT states, the simultaneous operation of the device as atomic frequency standard as well as atomic magnetometer is investigated. The magnetometer sensitivity can be further improved by utilizing the inherent option of magnetic field assisted synchronized radio frequency scanning.
In this work we propose, and experimentally demonstrate, the use of a self-oscillating all-optical atomic magnetometer for magnetic induction measurements. Given the potential for miniaturization of atomic magnetometers, and their extreme sensitivity, the present work shows that atomic magnetometers may play a key role in the development of instrumentation for magnetic induction tomography.
Miniaturized atomic magnetometers, particularly spin-exchange relaxation-free atomic magnetometers, have been emerging in clinical imaging applications such magnetocardiography and magnetoencephalography. Miniaturization, portability, and low cost are primary development targets for bio-magnetic imaging technologies, as well as high sensitivity and spatial and time resolution. In this paper, we propose a low-cost solution for a bio-magnetic imaging system based on atomic magnetometers, in which one laser source is used for a multi-channel atomic magnetometer sensor array. A novel design is dem…
We present a single-beam atomic magnetometer operating at room temperature for the measurement of ac magnetic fields. The magnetometer functions in the non-linear regime of magneto-optical rotation of $^{85}$Rb atomic vapour. We demonstrate a sensitivity of $\sim 0.9$ pT$/ \sqrt{Hz}$ at 2 kHz and a large bandwidth of 24 kHz. The dynamic range of measurement is $10^6$, making the sensor effective even in Earth's field. We present the signal-to-noise and bandwidth characteristics of the system for both shielded and unshielded modes of operation. Moreover, we perform theoretical analysis for the …
We present an experimental study of the intrinsic magnetometric sensitivity of an optical/rf-frequency double resonance magnetometer in which linearly polarized laser light is used in the optical pumping and detection processes. We show that a semi-empirical model of the magnetometer can be used to describe the magnetic resonance spectra. Then, we present an efficient method to predict the optimum operating point of the magnetometer, i.e., the light power and rf Rabi frequency providing maximum magnetometric sensitivity. Finally, we apply the method to investigate the evolution of the optimum …
The operation of polarimetric based single beam three axis atomic magnetometer is studied. The magnetometer operates in presence of small bias magnetic field. Its salient features are compared with the analysis of Bloch equation. The sensitivity of the device along three orthogonal directions are measured in low frequency regime, where 1/f noise adversely affect the sensitivity. The cross talk among the three axes magnetic field measurements and relative phase shifts are analysed using Lissajous plot. The sensitivity of the magnetometer is found to be < 10 pT/sqrt(Hz) @400 mHz in any direction…
Atomic co-magnetometers are widely used in precision measurements searching for spin interactions beyond the Standard Model. We describe a new $^3$He-$^{129}$Xe co-magnetometer probed by Rb atoms and use it to identify two general classes of systematic effects in gas co-magnetometers, one associated with diffusion in second-order magnetic field gradients and another due to temperature gradients. We also develop a general and practical approach for calculating spin relaxation and frequency shifts due to arbitrary magnetic field gradients and confirm it experimentally.
In atomic magnetometers, the vector AC-Stark shift associated with circularly polarized light generates spatially varying effective magnetic fields which limit the magnetometer response and serve as sources of noise. We describe a scheme whereby optically pumping a small sub-volume of the magnetometer cell and relying on diffusion to transport polarized atoms allows a magnetometer to be operated with minimal sensitivity to the AC-Stark field.
We propose and demonstrate a radio-frequency atomic magnetometer with sub-Doppler laser cooled rubidium-87. With a simple and compact design, our system demonstrates a sensitivity of $330~pT/\sqrt{Hz}$ in an unshielded environment, thus matching or surpassing previously reported cold atoms designs. By merging the multiple uses and robustness of radio-frequency atomic magnetometers with the detailed control of laser cooling, our cold atom radio-frequency magnetometer has the potential to move applications of atomic magnetometry to high spatial resolution. Direct impact in metrology for applied …
In this article, operation of optical magnetometers detecting static (DC) and oscillating (AC) magnetic fields is studied and comparison of the devices is performed. To facilitate the comparison, the analysis is carried out in the same experimental setup, exploiting nonlinear magneto-optical rotation. In such a system, a control over static-field magnitude or oscillating-field frequency provides detection of strength of the DC or AC fields. Polarization rotation is investigated for various light intensities and AC-field amplitudes, which allows to determine optimum sensitivity to both fields. …
We demonstrate detection of NMR signals using a non-cryogenic atomic magnetometer and describe several novel applications of this technique. A water free induction decay (FID) signal in a 0.5 $μ$T field is detected using a spin-exchange-relaxation-free K magnetometer and the possibility of using a multi-channel magnetometer for 3-D MRI requiring only a single FID signal is described. We also demonstrate detection of less than $10^{13}$ $^{129}$Xe atoms whose NMR signal is enhanced by a factor of 540 due to Fermi-contact interaction with K atoms. This technique allows detection of less than $10…
Optical magnetometers are currently able to achieve magnetometric sensitivities below 1 fT/Hz^1/2. Although such sensitivities are typically obtained for ultra-low-field measurements, a group of optical magnetometers allows the detection of the fields in much broader dynamic range without a significant compromise in the sensitivity. A particular example of such a device is the magnetometer exploiting amplitude-modulated nonlinear magneto-optical rotation. It enables to measure a magnetic field via detection of a polarization state of light traversing a medium subjected to the field. In this pa…
We have designed and tested an atomic vectorial magnetometer based on the analysis of the coherent oscillatory transients in the transmission of resonant laser light through a Rb vapor cell. We show that the oscillation amplitudes at the Larmor frequency and its first harmonic are related through a simple formula to the angles determining the orientation of the magnetic field vector. The magnetometer was successfully applied to the measurement of the ambient magnetic field.
The hybrid optical pumping spin exchange relaxation free (SERF) atomic magnetometers can realize ultrahigh sensitivity measurement of magnetic field and inertia. We have studied the $^{\text{85}}$Rb polarization of two types of hybrid optical pumping SERF magnetometers based on $^{\text{39}}$K-$^{\text{85}}$Rb-$^{\text{4}}$He and $^{\text{133}}$Cs-$^{\text{85}}$Rb-$^{\text{4}}$He respectively. Then we found that $^{\text{85}}$Rb polarization varies with the number density of buffer gas $^{\text{4}}$He and quench gas N$_{\text{2}}$, pumping rate of pump beam and cell temperature respectively, w…
This article is designed as a step-by-step guide to optically pumped magnetometers based on alkali atomic vapor cells. We begin with a general introduction to atomic magneto-optical response, as well as expected magnetometer performance merits and how they are affected by main sources of noise. This is followed by a brief comparison of different magnetometer realizations and an overview of current research, with the aim of helping readers to identify the most suitable magnetometer type for specific applications. Next, we discuss some practical considerations for experimental implementations, u…
We describe the development of a simple atomic magnetometer using $^{87}$Rb vapor suitable for Earth magnetic field monitoring. The magnetometer is based on time-domain determination of the transient precession frequency of the atomic alignment around the measured field. A sensitivity of 1.5 nT/$\sqrt{Hz}$ is demonstrated on the measurement of the Earth magnetic field in the laboratory. We discuss the different parameters determining the magnetometer precision and accuracy and predict a sensitivity of 30 pT/$\sqrt{Hz}$
We observe quantum beats with periodic revivals due to non-linear spacing of Zeeman levels in the ground state of potassium atoms and demonstrate their synchronous optical pumping by double modulation of the pumping light at the Larmor frequency and the revival frequency. We show that synchronous pumping increases the degree of spin polarization by a factor of 4. As a practical example, we explore the application of this double-modulation technique to atomic magnetometers operating in the geomagnetic field range and find that it can increase the sensitivity and reduce magnetic field orientatio…
We describe our research programme on the use of atomic magnetometers to detect conductive objects via electromagnetic induction. The extreme sensitivity of atomic magnetometers at low frequencies, up to seven orders of magnitude higher than a coil-based system, permits deep penetration through different media and barriers, and in various operative environments. This eliminates the limitations usually associated with electromagnetic detection.
A multi-channel atomic magnetometer operating in an unshielded environment is described and characterised. The magnetometer is based on D1 optical pumping and D2 polarimetry of Cs vapour contained in gas-buffered cells. Several technical implementations are described and discussed in detail. The demonstrated sensitivity of the setup is 100fT/Hz^1/2 when operating in the difference mode.
We demonstrated a scalar atomic magnetometer using a micro-fabricated Cs vapor cell. The atomic spin precession is driven by an amplitude-modulated circularly-polarized pump laser resonant on D1 transition of Cs atoms and detected by an off-resonant linearly-polarized probe laser using a balanced polarimeter setup. Under a magnetic field with amplitude in the Earth's magnetic field range, the magnetometer in the gradiometer mode can reach sensitivities below 150 fT/rt-Hz, which shows that the magnetometer by itself can achieve sub-100 fT/rt-Hz sensitivities. In addition to its high sensitivity…
We demonstrate detection of proton NMR signals with a radio frequency atomic magnetometer tuned to the NMR frequency of 62 kHz. High-frequency operation of the atomic magnetometer makes it relatively insensitive to ambient magnetic field noise. We obtain magnetic field sensitivity of 7 fT/Hz$^{1/2}$ using only a thin aluminum shield. We also derive an expression for the fundamental sensitivity limit of a surface inductive pick-up coil as a function of frequency and find that an atomic rf magnetometer is intrinsically more sensitive than a coil of comparable size for frequencies below about 50 …
A self-oscillating magnetometer based on the nonlinear magneto-optical rotation effect with separate modulated pump and unmodulated probe beams is demonstrated. This device possesses a bandwidth exceeding $1\khz$. Pump and probe are delivered by optical fiber, facilitating miniaturization and modularization. The magnetometer has been operated both with vertical-cavity surface-emitting lasers (VCSELs), which are well suited to portable applications, and with conventional edge-emitting diode lasers. A sensitivity of around $3 {\rm nG}$ is achieved for a measurement time of $1\s$.
We present a theoretical study of the spectra produced by optical-radio-frequency double resonance devices, in which resonant linearly polarized light is used in the optical pumping and detection processes. We extend previous work by presenting algebraic results which are valid for atomic states with arbitrary angular momenta, arbitrary rf intensities, and arbitrary geometries. The only restriction made is the assumption of low light intensity. The results are discussed in view of their use in optical magnetometers.
Noise properties of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement are considered. Such a magnetometer measures spin precession of $N$ atomic spins by detecting optical rotation of far-detuned light. Fundamental noise sources include the quantum projection noise and the photon shot-noise. For measurement times much shorter than the spin-relaxation time observed in the absence of light ($τ_{\rm rel}$) divided by $\sqrt{N}$, the optimal sensitivity of the magnetometer scales as $N^{-3/4}$, so an advantage over the usual sen…
We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/\sqrt(Hz) using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/\sqrt(Hz).
Scalar atomic magnetometers have many attractive features but their sensitivity has been relatively poor. We describe a Rb scalar gradiometer using two multi-pass optical cells. We use a pump-probe measurement scheme to suppress spin-exchange relaxation and two probe pulses to find the spin precession zero crossing times with a resolution of 1 psec. We realize magnetic field sensitivity of 0.54 fT/Hz$^{1/2}$, which improves by an order of magnitude the best scalar magnetometer sensitivity and surpasses the quantum limit set by spin-exchange collisions for a scalar magnetometer with the same me…
We present a portable four-channel atomic magnetometer array operating in the spin exchange relaxation-free regime. The magnetometer array has several design features intended to maximize its suitability for biomagnetic measurement, specifically foetal magnetocardiography, such as a compact modular design, and fibre coupled lasers. The modular design allows the independent positioning and orientation of each magnetometer, in principle allowing for non-planar array geometries. Using this array in a magnetically shielded room, we acquire adult magnetocadiograms. These measurements were taken wit…
Spin polarized atomic ensembles can be used for the precise measurement of magnetic field. Conventional atomic magnetometers have demonstrated high sensitivities, albeit at low detection bandwidth, fundamentally limited by the Larmor precession frequency of the atoms. Here, we introduce a new type of atomic magnetometer which can realize sensitive detection with high temporal resolution. The magnetometer is based on monitoring the effect of the magnetic field on the hyperfine coherences of spin-polarized hydrogen atoms produced from the rapid photodissociation of hydrogen chloride (HCl). This …
The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in-phase with the precessing magnetization. In an earth-range field, a multi-component asymmetric magnetic-resonance line with ? 60 Hz width collapses into …
We report an all-optical atomic vector magnetometer using dual Bell-Bloom optical pumping beams in a Rb vapor cell. This vector magnetometer consists of two orthogonal optical pumping beams, with amplitude modulations at $^{85}$Rb and $^{87}$Rb Larmor frequencies respectively. We simultaneously detect atomic signals excited by these two pumping beams using a single probe beam in the third direction, and extract the field orientation information using the phase delays between the modulated atomic signals and the driving beams. By adding a Herriott cavity inside the vapor cell, we improve the ma…
Under negative feedback, the quality factor Q of a radio-frequency magnetometer can be decreased by more than two orders of magnitude, so that any initial perturbation of the polarized spin system can be rapidly damped, preparing the magnetometer for detection of the desired signal. We find that noise is also suppressed under such spin-damping, with a characteristic spectral response corresponding to the type of noise; therefore magnetic, photon-shot, and spin-projection noise can be measured distinctly. While the suppression of resonant photon-shot noise implies the closed-loop production of …
We present magnetic detection of a single, 2 μm diameter cobalt microparticle using an atomic magnetometer based on a microfabricated vapor cell. These results represent an improvement by a factor of 105 in terms of the detected magnetic moment over previous work using atomic magnetometers to detect magnetic microparticles. The improved sensitivity is due largely to the use of small vapor cells. In an optimized setup, we predict detection limits of 0.17 μm^3.
We show that a single atomic magnetometer in a magnetically unshielded environment can be used to perform magnetic particle spectroscopy (MPS) and AC susceptometry (ACS) on liquid-suspended magnetic nanoparticles. We demonstrate methods allowing a simultaneous recording of M(H) and dM/dH(H) dependences of samples containing down to 1 $μ$g of iron. Our results pave the way towards an atomic magnetometer based MPI scanner.
In recent years diode laser sources have become widespread and reliable tools in magneto-optical spectroscopy. In particular, laser-driven atomic magnetometers have found a wide range of practical applications. More recently, so-called magnetically silent variants of atomic magnetometers have been developed. While in conventional magnetometers the magnetic resonance transitions between atomic sublevels are phase-coherently driven by a weak oscillating magnetic field, silent magnetometers use schemes in which either the frequency (FM) or the amplitude (AM) of the light beam is modulated. Here w…
The Bell-Bloom-type optically-pumped FID Rubidium atomic magnetometer with a multi-passing probe beam and two counter-propagating pump beams
State Key Laboratory of Quantum Optics Technologies and Devices, and Institute of Optoelectronics, Shanxi University(山西大学量子光学器件与量子光学技术国家重点实验室及光电研究所);School of Physics and Electronic Engineering, Shanxi University(山西大学物理电子工程学院);Collaborative Innovation Center of Extreme Optics, Shanxi University(山西大学极端光学协同创新中心)
A novel experimental scheme enabling investigation of transient exotic spin couplings is discussed. The scheme is based on synchronous measurements of optical-magnetometer signals of several devices operating in magnetically shielded environments in distant locations ($\gtrsim100$ km). Although signatures of such exotic couplings may be present in the signal from a single magnetometer, it would be challenging to distinguish them from noise. By analyzing the correlation between signals from multiple, geographically separated magnetometers, it is not only possible to identify the exotic transien…
We demonstrate Magnetic Induction Tomography (MIT) with an all-optical atomic magnetometer. Our instrument creates a conductivity map of conductive objects. Both shape and size of the imaged samples compare very well with the actual shape and size. Given the potential of all-optical atomic magnetometers for miniaturization and extreme sensitivity, the proof-of-principle presented here opens up promising avenues in the development of instrumentation for magnetic induction tomography.
We demonstrate electromagnetic induction imaging with an unshielded, portable radio-frequency atomic magnetometer scanning over the target object. This configuration satisfies standard requirements in typical applications, from security screening to medical imaging. The ability to scan the magnetometer over the object relies on the miniaturization of the sensor head and on the active compensation of the ambient magnetic field. Additionally, a procedure is implemented to extract high-quality images from the recorded spatial dependent magnetic resonance. The procedure is shown to be effective in…
We demonstrate the sensitivity of a sensor based on an optically-pumped radio-frequency (RF) atomic magnetometer to the polarization state of the detected RF magnetic field, and measure $>$36 dB difference in amplitude sensitivity for opposite circular field polarizations. This sensitivity could be used to create novel sensors that would allow signal detection while suppressing the ambient noise, regardless of the distance between the sources of signal and noise, in contrast to traditional gradiometry configurations. Additionally, such sensor will be orientation-sensitive, as the phase of the …
We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D$_2$ line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment and spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field diffe…
We report on a compact, tunable, and scalable to large arrays imaging device, based on a radio-frequency optically pumped atomic magnetometer operating in magnetic induction tomography modality. Imaging of conductive objects is performed at room temperature, in an unshielded environment and without background subtraction. Conductivity maps of target objects exhibit not only excellent performance in terms of shape reconstruction but also demonstrate detection of sub-millimetric cracks and penetration of conductive barriers. The results presented here demonstrate the potential of a future genera…
Atomic magnetometry was performed at Earth's magnetic field over a free-space distance of ten meters. Two laser beams aimed at a distant alkali-vapor cell excited and detected the $^{87}$Rb magnetic resonance, allowing the magnetic field within the cell to be interrogated remotely. Operated as a driven oscillator, the magnetometer measured the geomagnetic field with \lessgtrsim{\lesssim}3.5\,pT precision in a $\sim$2\,s data acquisition; this precision was likely limited by ambient field fluctuations. The sensor was also operated in self-oscillating mode with a 5.3\,pT/$\sqrt{\textrm{Hz}}$ noi…
We demonstrate novel implementations of high-precision optical magnetometers which allow for spatially-selective and spatially-resolved in situ measurements using cold atomic clouds. These are realised by using shaped dispersive probe beams combined with spatially-resolved balanced homodyne detection. Two magnetometer sequences are discussed: a vectorial magnetometer, which yields sensitivities two orders of magnitude better compared to a previous realisation and a Larmor magnetometer capable of measuring absolute magnetic fields. We characterise the dependence of single-shot precision on the …
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating…
Detection and imaging of an electrically conductive object at a distance can be achieved by inducing eddy currents in it and measuring the associated magnetic field. We have detected low-conductivity objects with an optical magnetometer based on room-temperature cesium atomic vapor and a noise-canceling differential technique which increased the signal-to-noise ratio (SNR) by more than three orders of magnitude. We detected small containers with a few mL of salt-water with conductivity ranging from 4-24 S/m with a good SNR. This demonstrates that our optical magnetometer should be capable of d…
We describe an ultra-sensitive atomic magnetometer using optically-pumped potassium atoms operating in spin-exchange relaxation free (SERF) regime. We demonstrate magnetic field sensitivity of 160 aT/Hz$^{1/2}$ in a gradiometer arrangement with a measurement volume of 0.45 cm$^3$ and energy resolution per unit time of $44 \hbar$. As an example of a new application enabled by such a magnetometer we describe measurements of weak remnant rock magnetization as a function of temperature with a sensitivity on the order of 10$^{-10}$ emu/cm$^3$/Hz$^{1/2}$ and temperatures up to 420$^\circ$C.
We present experimental data and theoretical interpretation of NMR spectra of remotely magnetized samples, detected in an unshielded environment by means of a differential atomic magnetometer. The measurements are performed in an ultra-low-field at an intermediate regime, where the J-coupling and the Zeeman energies have comparable values and produce rather complex line sets, which are satisfactorily interpreted.
Ultra-low field (ULF) MRI is a promising method for inexpensive medical imaging with various additional advantages over conventional instruments such as low weight, low power, portability, absence of artifacts from metals, and high contrast. Anatomical ULF MRI has been successfully implemented with SQUIDs, but SQUIDs have the drawback of cryogen requirement. Atomic magnetometers have sensitivity comparable to SQUIDs and can be in principle used for ULF MRI to replace SQUIDs. Unfortunately some problems exist due to the sensitivity of atomic magnetometers to magnetic field and gradients. At low…
We describe here the construction and characterization of a high-resolution optical magnetometer to measure the full vector magnetic field on an ultrathin layer near the surface of the device. This solid-state device is based on quantum sensors created by a layer of nitrogen-vacancy (NV) centers less than 20 nm below the surface of an ultrapure diamond. This ensemble of nanosensors provides a versatile device capable of mapping magnetic fields and surface current densities with a sub-micrometer resolution and high sensitivity, making it suitable for many applications. Here, we show a custom-bu…
We described a novel technique that can find the zero-field for unshielded laser-pumped atomic magnetometer using atomic signal itself. By comparing light density of pump beam after atomic vapor cell, it is decided which direction to move the compensation magnetic field and whether to increase or decrease the converging step length. The zero-field is found in less than 18s and the step length after converging is smaller than 10nT, 10nT and 40nT for x, y and z axes, respectively, limited by 50Hz noise in the lab environment.
We demonstrate a fast three-axis optical magnetometer using cold, optically-trapped $^{87}$Rb gas as a sensor. By near-resonant Faraday rotation we record the free-induction decay following optical pumping along two orthogonal axes to obtain the three field components and one gradient component. A single measurement achieves shot-noise limited sub-nT sensitivity in 1 ms, with transverse spatial resolution of $\sim$ 20 $μ$m. We make a detailed analysis of the shot-noise-limited sensitivity.