The operation of polarimetric based single beam three axis atomic magnetometer is studied. The magnetometer operates in presence of small bias magnetic field. Its salient features are compared with the analysis of Bloch equation. The sensitivity of the device along three orthogonal directions are measured in low frequency regime, where 1/f noise adversely affect the sensitivity. The cross talk among the three axes magnetic field measurements and relative phase shifts are analysed using Lissajous plot. The sensitivity of the magnetometer is found to be < 10 pT/sqrt(Hz) @400 mHz in any direction. The investigated magnetometer is suitable for space application, where overall size of the device is of prime importance.
Accurate Vector Magnetometer via Zeeman Rabi Oscillations
JILA, National Institute of Standards and Technology and University of Colorado(美国国家标准与技术研究院与科罗拉多大学JILA联合研究所);Department of Physics, University of Colorado(科罗拉多大学物理系);ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology(巴塞罗那科学技术研究所光子科学研究所);Paul M. Rady Department of Mechanical Engineering, University of Colorado(科罗拉多大学保罗·M·雷迪机械工程系);FieldLine Medical(FieldLine医疗公司)
Microfabricated multi-axis cell for integrated atomic devices
Univ. Lille, CNRS, Centrale Lille, Univ. Polytechnique Hauts-de-France, UMR 8520 - IEMN - Institut d’Electronique de Microélectronique et de Nanotechnologie(里尔大学,法国国家科学研究中心,里尔中央理工学院,上法兰西工业大学,联合研究单位8520 - 微电子与纳米技术研究所);Université Marie et Louis Pasteur, CNRS, SUPMICROTECH, institut FEMTO-ST(玛丽和路易·巴斯德大学,法国国家科学研究中心,SUPMICROTECH,FEMTO-ST研究所)