双轴π脉冲自旋交换无弛豫磁强计

Dual-axis pi-pulse spin-exchange relaxation-free magnetometer

Elena Zhivun, Michael Bulatowicz, Alexander Hryciuk, Thad Walker

摘要:

我们提出了一种新的自旋交换弛豫自由矢量磁强计与抑制1/f探针噪声,通过施加一个小的直流偏置场和梳状磁直流$π$脉冲沿泵浦方向。这导致其两个敏感轴中的每一个的同步正交AC响应。新的磁力计特别适合于生物磁力学等应用,其中待测量的信号在低频下携带其功率的主要分量。磁力计在0.01 Hz时达到8.4 fT/sqrt(Hz)(x)和11 fT/sqrt(Hz)(y)的技术本底噪声。共享相同实验装置的单轴DC SERF在相同频率下达到61 fT/sqrt(Hz)。新磁力计在10 Hz时达到1.1 fT/sqrt(Hz)(x)和2.0 fT/sqrt(Hz)(y)的噪声最小值,而DC SERF在25 Hz时为0.7 fT/sqrt(Hz)。

英文摘要:

We present a new spin-exchange relaxation-free vector magnetometer with suppressed 1/f probe noise, achieved by applying a small DC bias field and a comb of magnetic DC $π$ pulses along the pump direction. This results in a synchronous orthogonal AC response for each of its two sensitive axes. The new magnetometer is particularly well-suited to applications such as biomagnetism in which the signal to be measured carries a dominant component of its power at low frequencies. The magnetometer reaches a technical noise floor of 8.4 fT/sqrt(Hz) (x) and 11 fT/sqrt(Hz) (y) at 0.01 Hz. A single-axis DC SERF sharing the same experimental apparatus attains 61 fT/sqrt(Hz) at the same frequency. A noise minimum of 1.1 fT/sqrt(Hz) (x) and 2.0 fT/sqrt(Hz) (y) is reached by the new magnetometer at 10 Hz, compared to 0.7 fT/sqrt(Hz) at 25 Hz for a DC SERF.