It is difficult for us to measure the Booster ring impedance up to the GHz range due to the instrumentation limit. Since the de-bunching process in the Linac to Booster transfer is determined by the complex impedance of the Booster ring, one can obtain an impedance model, which has the best match to the machine impedance, just by searching the optimal fit between the simulated and measured turn-by-turn resistive wall signal (RWS).
The match between the Linac beam energy and the energy determined by the bending field of the Booster magnets is crucial for rf capture, beam quality, and the transmission efficiency in a Booster cycle. The observation of the injection energy match is important for injection tuning. Several signals, such as phase shift drive (PSD), radial position error (RPOS), synchrotron phase (SPD), and fast phase error (FPERR), provide consistent information on the energy match and can be used for a injection match tuning.
Fermilab is committed to upgrade its accelerator complex to support HEP experiments at the intensity frontier. The ongoing Proton Improvement Plan (PIP) enables us to reach 700 kW beam power on the NuMI neutrino targets. By the end of the next decade, the current 400 MeV normal conducting LINAC will be replaced by an 800 MeV superconducting LINAC (PIP-II) with an increased beam power >50% of the PIP design goal. Both in PIP and PIP-II era, the existing Booster is going to play a very significant role, at least for next two decades. In the meanwhile, we have recently developed an innovative bea…
In synchrotron machines, the beam extraction is accomplished by a combination of septa and kicker magnets which deflect the beam from an accelerator into another. Ideally the kicker field must rise/fall in between the beam bunches. However, in reality, an intentional beam-free time region (aka "notch") is created on the beam pulse to assure that the beam can be extracted with minimal losses. In the case of the Fermilab Booster, the notch is created in the ring near injection energy by the use of fast kickers which deposit the beam in a shielded collimation region within the accelerator tunnel.…
The injector linacs of the JLC/NLC project include the prelinac, the e+ drive linac, the $e- booster, and the $e+ booster. The first three will be S-band machines, the last one, an L-band machine. We have demonstrated that by using detuning alone in the accelerator structure design of these linacs we will have acceptable tolerances for emittance growth due to both injection jitter and structure misalignments, for both the nominal (2.8ns) and alternate (1.4ns) bunch spacings.
The injector linacs of the JLC/NLC comprise the e+ booster, the e- drive linac, the e+ booster, and the two prelinacs. These four systems together transport the two types of beams from the 80 MeV point at the end of their respective bunchers up to the storage rings, and then from the storage rings to the 10 GeV point at the beginning of the bunch compressors. Nominally, the e+ booster structure will be L-band and the others S-band. In transport through these linacs it is important that the emittances and particle losses stay within specified tolerances. In particular, the effects of the dipole…
Over the past decade, Fermilab has focused efforts on the intensity frontier physics and is committed to increase the average beam power delivered to the neutrino and muon programs substantially. Many upgrades to the existing injector accelerators, namely, the current 400 MeV LINAC and the Booster, are in progress under the Proton Improvement Plan (PIP). Proton Improvement Plan-II (PIP-II) proposes to replace the existing 400 MeV LINAC by a new 800 MeV LINAC, as an injector to the Booster which will increase Booster output power by nearly a factor of two from the PIP design value by the end of…
The Fermilab Proton Improvement Plan (PIP) was formed in late 2011 to address important and necessary upgrades to the Proton Source machines (Injector line, Linac and Booster). The goal is to increase the proton flux by doubling the Booster beam cycle rate while maintaining the same intensity per cycle, the same uptime, and the same residual activation in the enclosure. For the Linac, the main focus within PIP is to address reliability. One of the main tasks is to replace the present hard-tube modulator used on the 200 MHz RF system. Plans to replace this high power system with a Marx-topology…
A test of the acceleration of multiple charge-state uranium beams was performed at the ATLAS accelerator. A 238U+26 beam was accelerated in the ATLAS PII linac to 286 MeV (~1.2 MeV/u) and stripped in a carbon foil located 0.5 m from the entrance of the ATLAS Booster section. A 58Ni9+ 'guide' beam from the tandem injector was used to tune the Booster for 238U+38. All charge states from the stripping were injected into the booster and accelerated. Up to 94% of the beam was accelerated through the Booster linac, with losses mostly in the lower charge states. The measured beam properties of each c…
The first phase of the HIE-ISOLDE project at CERN consists of a superconducting (SC) linac upgrade in order to increase the energy of post-accelerated radioactive ion beams from 2.8 MeV/u to over 10 MeV/u (for A/q = 4.5). In preparation for the upgrade, we present beam dynamics studies of the booster section of the normal conducting (NC) REX-ISOLDE linac, focused on the longitudinal development of the beam in the 101.28 MHz Interdigital H-mode Structure (IHS), employing a Combined Zero Degree Structure (KONUS), pulsing at a high gradient of over 3 MV/m. The evolution of the transverse emittanc…
As the pre-injector of the LHC injector chain, the proton linac at CERN is required to provide a high-intensity (180mA) beam to the Proton Synchrotron Booster. The results of measurements at this intensity will be presented. Furthermore, the linac is now equipped with bunch shape monitors from INR, Moscow, which have allowed the comparison of the Alvarez tank RF settings with simulations.
To improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon, the Low Energy RHIC electron Cooler (LEReC) is currently under commissioning at BNL. The Linac of LEReC is designed to deliver a 1.6 MeV to 2.6 MeV electron beam, with rms dp/p less than 5e-4. A 704 MHz superconducting radio frequency (SRF) booster cavity in this Linac provides up to 2.2 MeV accelerating voltage. With such a low energy and very demanding energy spread requirement, control of Higher Order Modes (HOMs) in the cavities becomes critical and needs to be carefully evaluated to ensure minimum impact on the b…
In the last ten years the use of proton beams in radiation therapy has become a clinical tool for treatment of deep-seated tumours. LIBO is a RF compact and low cost proton linear accelerator (SCL type) for hadrontherapy. It is conceived by TERA Foundation as a 3 GHz Linac Booster, to be mounted downstream of an existing cyclotron in order to boost the energy of the proton beam up to 200 MeV, needed for deep treatment (~25 cm) in the human body. With this solution it is possible to transform a low energy commercial cyclotron, normally used for eye melanoma therapy, isotope production and nucle…
Fermilab is committed to upgrading its accelerator complex towards the intensity frontier to pursue HEP research in the neutrino sector and beyond. The upgrade has two steps: 1) the Proton Improvement Plan (PIP), which is underway, has its primary goal to start providing 700 kW beam power on NOvA target by the end of 2017 and 2) the foreseen PIP-II will replace the existing LINAC, a 400 MeV injector to the Booster, by an 800 MeV superconducting LINAC by the middle of next decade, with output beam intensity from the Booster increased significantly and the beam power on the NOvA target increased…
At the Fermilab Booster, and many other proton facili-ties, an intense proton beam is accumulated by multi-turn injection of an H- beam through a stripping foil. The circu-lating beam scatters off the injection foil and large-angle Coulomb scattering leads to uncontrolled losses concen-trated in the first betatron period. We measure the foil scat-tering loss rate in the Fermilab Booster as a function of LINAC current, number of injection turns, and time on the injection foil. We find that current Booster operation has ~1% foil scattering loss and we make projections for the Proton Improvement …
The first version of digital low level RF (DLLRF) for the Diamond Light Source storage ring and booster was developed with ALBA Synchrotron. Six systems have been built so far. Two of them are in routine operation controlling two normal conducting HOM-damped cavi-ties in the Diamond storage ring. A third system is being used for cavity testing in the RF test facility (RFTF). The fourth system is being commissioned to control the sec-ond normal conducting booster cavity. The fifth DLLRF system is being prepared for the third normal conducting RF cavity in the storage ring. A new DLLRF system ba…
LINAC 4 is a normal conducting H- structure proposed to intensify the proton flux currently available for the CERN accelerator chain. This linac is designed to accelerate a 65 mA beam up to 160 MeV to be injected into the CERN Proton Synchrotron Booster. The acceleration is performed up to 3 MeV by a Radio-Frequency Quadrupole resonating at 352 MHz followed by a serie of two drift tube systems (conventional Alvarez and Cell Coupled Drift Tube Linac) boosting the beam up to 90 MeV at 352 MHz and finished by a Side Coupled Linac at 704 MHz. Beam dynamics was studied and optimized performing end-…
PIP-II is the Fermilab's flagship project for providing powerful, high-intensity proton beams to the laboratory's experiments. The heart of PIP-II is an 800-MeV superconducting linac accelerator. It will be located in a new tunnel with new service buildings and connected to the present Booster through a new transfer line. To support the design of civil engineering and mechanical integration, this paper provides preliminary estimation of radiation level in the gallery at an operational beam loss limit of 0.1 W/m, by means of Monte Carlo calculations with FLUKA and MARS15 codes.
The peak current limit for the Fermilab Linac was recently studied. The purpose was to learn what components of the present Linac can be used for the first stage of a proposed proton driver[1]. For this application the Linac must provide a H- beam in excess of 5000 mA-msec per pulse. The original Fermilab Linac was designed for protons with a peak current of 75 mA and a pulse length of four Booster turns (~10 msec). The high energy replacement was designed for a peak current of 35 mA and a beam pulse length of 50 msec. The present H- source cannot deliver more than ~80 mA which produces 55 mA …
The Fermilab Proton Source machines, constituted by Pre-Injector, conventional Linac and Booster synchrotron, at Fermi National Accelerator Laboratory (Fermilab) had have a long history of successful beam operations. Built in late '60s, the Fermilab Proton Source began operations early in the '70s and since then it has successful provided protons to support the laboratory physics experiments. During the past decade, Booster performance reached unprecedented proton flux delivery of the order of 1.0-1.1E17 protons per hour, corresponding to 40 kW of beam power while maintained an allowed upper l…
We have developed a computer program interfaced with the ACNET environment of Fermilab accelerators to measure energy spread of the proton beam from the LINAC at an injection into the Booster. It uses a digitizing oscilloscope and provides users an ability to configure the scope settings for optimal data acquisition from a resistive wall current monitor. When the program is launched, a) a ${\it one\ shot\ timeline}$ is generated to initiate beam injection into the Booster, b) a gap of about 40 ns is produced in the injected beam using a set of fast kickers, c) collects line charge distribution…
Increasing peak brightness is beneficial to various applications of Thomson scattering x-ray source. Higher peak brightness of scattered x-ray pulse demands shorter scattering electron beam realized by beam compression in electron beam-line. In this article, we study the possibility to compress electron beam in a typical S-band normal conducting photo-injector via ballistic bunching, through just adding a short RF linac section right behind the RF gun, so as to improve peak brightness of scattered x-ray pulse. Numerical optimization by ASTRA demonstrations that peak current can increase from ~…
The High Intensity Gamma-ray Source (HIGS) at Duke University is an accelerator-driven Compton gamma-ray source, providing high flux gamma-ray beam from 1 MeV to 100 MeV for photo-nuclear physics research. The HIGS facility operates three accelerators, a linac pre-injector (0.16 GeV), a booster injector (0.16-1.2 GeV), and an electron storage ring (0.24-1.2 GeV). Because of proximity of the booster injector to the storage ring, the magnetic field of the booster dipoles close to the ring can significantly alter the closed orbit in the storage ring being operated in the low energy region. This t…
The 40-year-old Fermilab Proton Source machines, constituted by the Pre-Injector, Linac and the synchrotron Booster, have been the workhorse of the Fermi National Accelerator Laboratory (Fermilab). During this time, the High Energy Physics Program has demanded an increase in proton throughput, especially during the past decade with the beginning of the neutrino program at Fermilab. In order to achieve a successful program, major upgrades and changes were made in Booster. Once again, the Proton Source has been charged to double their beam throughput, while maintain the present residual activati…
The MTA beam line has been specifically designed to facilitate measurements of the Fermilab Linac beam emittance and properties utilizing a long, 10m, element-free straight. Linac beam is extracted downstream of the 400-MeV electrostatic chopper located in the Booster injection line. This chopper cannot be utilized for MTA beam, and therefore the entire Linac beam pulse is directed into the MTA beamline. Pulse length manipulation is provided by the 750-keV electrostatic chopper at the upstream end of the Linac and, using this device, beam can be delivered from 8 μsec up to the full 50 μsec Lin…
The completion of the PIP-II project and its superconducting linear accelerator will provide up to 1.2 MW of beam power to the LBNF/DUNE facility for neutrino physics. It will also be able to produce high-power beams directly from the linac that can be used for lower-energy particle physics experiments as well, such as directing beam toward the Muon Campus at Fermilab for example. Any further significant upgrade of the beam power to DUNE, however, will be impeded by the limitations of the present Booster synchrotron at the facility. To increase the power to DUNE by a factor of two would requir…
Longitudinal space charge (LSC) effects are generally considered harmful in free-electron lasers as they can seed unfavorable energy modulations that can result in density modulations with associated emittance dilution. It was pointed out, however, that such "micro-bunching instabilities" could be potentially useful to support the generation of broadband coherent radiation. Therefore there has been an increasing interest in devising accelerator beam lines capable of controlling LSC induced density modulations. In the present paper we augment these previous investigations by combining a grid-le…
In order to double the positron injection rate into the KEKB ring, a two-bunch acceleration scheme has been studied at the linac, in which bunches separated by 96 ns are accelerated in 50 Hz. In this scheme the stabilization of energy and orbit of each bunch is indispensable. Thus the beam energy and orbit feedback systems have been upgraded. Since beam characteristics are acquired through beam position monitors (BPM), their read-out system was improved to meet two-bunch requirements. Combined waveforms from BPM's were adjusted with delay cables avoiding overlaps and they enabled simultaneous …
Sirius is a Synchrotron Light Source Facility based on a 4th generation low emittance storage ring. The facility is presently in the final assembly phase in Campinas, Brazil, and comprises a 3 GeV electron storage ring, a full energy Booster and a 150 MeV Linac. The Booster RF system is based on a single 5-cell RF cavity driven by a 45 kW amplifier at 500 MHz and is designed to operate at 2 Hz repetition rate. The storage ring will initially use one normal conducting 7-cell RF cavity and, in the final configuration, will comprise two superconducting cavities, each one driven by a 240 kW RF amp…
We report the results of a recent beam dynamics study, motivated by the need to redesign the LCLS photoinjector, that lead to the discovery of a new effective working point for a split RF photoinjector. We consider the emittance compensation regime of a space charge beam: by increasing the solenoid strength, the emittance evolution shows a double minimum behavior in the drifting region. If the booster is located where the relative emittance maximum and the envelope waist occur, the second emittance minimum can be shifted to the booster exit and frozen at a very low level (0.3 mm-mrad for a 1 n…
The FNAL accelerator complex is poised to reach MW neutrino beams on target for the exploration of the dark sector physics and rare physics program spaces. Future operations of the complex will include CW linac operations at beam intensities that have not been seen before \cite{PIP2,RCS_LOI}. The ambitious beam program relies on multi-turn H$^{-}$ injection into the FNAL Booster and then extracted into delivery rings or the Booster Neutrino Beam (BNB) 8 GeV HEP program. A new rapid-cycling synchrotron (RCS) will be required to reach the LBNF goal of 2.4 MW because of intense space-charge limit…
The design of the Linac Coherent Light Source assumes that a low-emittance, 1-nC, 10-ps beam will be available for injection into the 15-GeV linac. The proposed rf photocathode injector that will provide a 150-MeV beam with rms normalized emittances of 1 mm in both the transverse and longitudinal dimensions is based on a 1.6-cell S-band rf gun that is equipped with an emittance compensating solenoid. The booster accelerator is positioned at the beam waist coinciding with the first emittance maximum and is provided with an accelerating gradient of ~25 MeV/m, i.e., the "new working point." The u…
The Low Energy RHIC electron Cooler (LEReC) is currently under commissioning at BNL to improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon. The linac of LEReC consists of a DC photoemission gun, one 704 MHz superconducting radio frequency (SRF) booster cavity, and three normal conducting cavities. It is designed to deliver a 1.6 MeV to 2.6 MeV electron beam, with peak-to-peak momentum spread dp/p of less than 7e4. Two of the three normal conducting cavities will be used in LEReC for energy spread correction. A single-cell 704 MHz cavity for energy de-chirping and a three-c…