Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode
R. Bellazzini, F. Angelini, L. Baldini, F. Bitti, A. Brez, L. Latronico, M. M. Massai, M. Minuti, N. Omodei, M. Razzano, C. Sgro, G. Spandre, E. Costa, P. Soffitta
备注:
11 pages, 14 figures, presented at the Xth Vienna Conference on Instrumentation (Vienna, February 16-21 2004). For a higher resolution paper contact gloria.spandre@pi.infn.it
In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the individual pixel to the external electronics chain. For this reason a custom CMOS array of 2101 active pixels with 80 micron pitch, directly used as the charge collecting anode of a GEM amplifying structure, has been developed and built. Each charge collecting pad, hexagonally shaped, realized using the top metal layer of a deep submicron VLSI technology is individually connected to a full electronics chain (pre-amplifier, shaping-amplifier, sample and hold, multiplexer) which is built immediately below it by using the remaining five active layers. The GEM and the drift electrode window are assembled directly over the chip so the ASIC itself becomes the pixelized anode of a MicroPattern Gas Detector. With this approach, for the first time, gas detectors have reached the level of integration and resolution typical of solid state pixel detectors. Results from the first tests of this new read-out concept are presented. An Astronomical X-Ray Polarimetry application is also discussed.
Development and characterization of hybrid MCP-PMT with embedded Timepix4 ASIC used as pixelated anode
INFN, Division of Ferrara(意大利国家核物理研究所费拉拉分部);Dept. of Physics and Earth Science, University of Ferrara(费拉拉大学地球科学与物理学系);EP Department, CERN(欧洲核子研究中心实验物理部)
Multiple application-specific integrated circuits (ASIC) are required for the detectors if their readout channels are larger than that of ASIC channels. For a system with such a readout scheme, there is a need to configure channels among ASICs to achieve the lowest electronics noise and highest count rate. In this work, experiments were performed to investigate the performance of two different readout configurations between two ASICs in a cross-strip cadmium zinc telluride detector. A lower electronic noise level, better FWHM energy resolution performance, and higher count rate was found for t…
Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can…
We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of $6\times6\times20{\rm mm}^3$ which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to readout every anode. The others are based on resistive charge divider network between anodes to reduce readout channels. In both systems, each pixel (6mm) was clearly resolved by flood field irradiation of $^{137}$Cs. We als…
An innovative X-ray imaging sensor with intrinsic digital characteristics is presented. It is based on Chromatic Photon Counting technology. The detector is able to count individually the incident X-ray photons and to separate them according to their energy (two 'color' images per exposure). The energy selection occurs in real time and at radiographic imaging speed (GHz global counting rate). Photon counting, color mode and a very high spatial resolution (more than 10 l.p./mm at MTF50) allow to obtain an optimal ratio between image quality and absorbed dose. The individual block of the imaging…
Single photon sensitive detectors used in high energy physics are, in some applications, required to cover areas the size of several m2, and more specifically in very strong demand with15 an ever finer imaging and timing capability for Cherenkov Ring Imaging Detector (RICH) configurations. We are evaluating the Large Area Picosecond Photo-detector (LAPPD) produced by INCOM company, as a possible candidate for future RICH detector upgrades. In this work we perform tests on the second generation device, which is capacitively coupled to a custom designed anode back plane, consisting of various pi…
We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating the analog and digital-front end electronics. This assembly will be capable of detecting up to $10^9$ photons per second with simultaneous measurement of position and time. The pixelated read-out anode used is based on the Timepix4 ASIC ($65~\mathrm{nm}$ CMOS technology) designed in the framework of the Medipix4 collaboration. This ASIC is an array of $512\…
An Application Specific Integrated Circuit (ASIC), called RIGEL, designed for the sparse readout of a Silicon Pixel Drift Detector (PixDD) for space applications is presented.The low leakage current (less than 1 pA at +20 °C) and anode capacitance (less than 40 fF) of each pixel (300 um x 300 um) of the detector, combined with a low-noise electronics readout, allow to reach a high spectroscopic resolution performance even at room temperature. The RIGEL ASIC front-end architecture is composed by a 2-D matrix of 128 readout pixel cells (RPCs), arranged to host, in a 300 um-sided square area, a c…
A novel read-out architecture has been developed for the Micromegas detector. The anode element is made of a resistive layer on a ceramic substrate. The detector part is entirely separated from the read-out element. Without significant loss, signals are transmitted by capacitive coupling to the read-out pads. The detector provides high gas gain, good energy resolution and the resistive layer assures spark protection to the electronics. This assembly could be combined with modern pixel array electronic ASICs. This readout organization is free on how the pixels are designed, arranged and connect…
Piggyback Micromegas consists in a novel readout architecture where the anode element is made of a resistive layer on a ceramic substrate. The resistive layer is deposited on the thin ceramic substrate by an industrial process which provides large dynamic range of resistivity (10$^6$ to 10$^{10}$\,M$Ω$/square). The particularity of this new structure is that the active part is entirely dissociated from the read-out element. This gives a large flexibility on the design of the anode structure and the readout scheme. Without significant loss, signals are transmitted by capacitive coupling to the …
ITACA revisited: Ion Tracking Apparatus with CMOS ASICs
Donostia International Physics Center(多诺西亚国际物理中心);Ben-Gurion University of the Negev(内盖夫本-古里安大学);Instituto de Física Corpuscular (IFIC, CSIC-UV)(粒子物理研究所(IFIC,CSIC-UV))
We present measurements with a GEM based TPC prototypes and the TimePix CMOS ASIC as charge collecting anode. Tests with a small prototype were performed in a 5 GeV electron beam at DESY. Different GEM orientations and geometries were tested. It is shown that the point resolution for short drift distances is better than 20 micrometer. The achieved time resolution is better than 10 ns at 100 MHz clock frequency. Furthermore, experimental studies with an enlarged pixel size are addressed. To study the performance for longer drift distances a chamber with 26 cm drift length is operated in Bonn. U…
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated Circuit (ASIC) built in deep sub-micron technology has been developed to realize a monolithic device that is, at the same time, the pixelized charge collecting electrode and the amplifying, shaping and charge measuring front-end electronics. The CMOS chip has the top metal layer patterned in a matrix of 80 micron pitch hexagonal pixels, each of them directly …
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which represents a big step forward both in terms of size and performance, is the last version of three generations of custom ASICs of increasing complexity. The CMOS pixel array has the top metal layer patterned in a matrix of 105600 hexagonal pixels at 50 micron pitch. Each pixel is directly connected to the underneath full electronics chain which has been realized in t…
We report on the results of a new, sealed, Gas Pixel Detector. The very compact design and the absence of the gas flow system, make this detector substantially ready for use as focal plane detector for future X-ray space telescopes. The instrument brings high sensitivity to X-ray polarimetry, which is the last unexplored field of X-ray astronomy. It derives the polarization information from the track of the photoelectrons that are imaged by a high gain (>1000), fine pitch GEM that matches the pitch of a pixel ASIC which is the collecting anode of the GPD (105k, 50 micron wide, hexagonal cells)…
MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysis Library) is able to measurethe performance of a MPGD detector with a strip segmented anode (presently). The code isdivided in three parts: reconstruction, where the hits are digitized and clusterize…
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collecting anode. In this paper we shall review the design, manufacturing, and test of the IXPE focal-plane detectors, with particular emphasis on the connection between the science drivers, the performance me…