Gsi强流注入器的新型气提器和电荷态分离器
The New Gas Stripper and Charge State Separator of the Gsi High Current Injector
摘要:
1999年,GSI Unilac被升级为SIS的高电流注入器。因此,在1.4 MeV/u的剥离部分[1]中,必须建立最高空间电荷条件下的束流传输和多束流操作,这是全新设计的。将介绍汽提塔部分的调试结果。束流传输到新的气体剥离器,并在空间电荷条件下的电荷状态分析证实了计算。来自MEVVA离子源并由新注入器直线加速器加速的238 U4+束被剥离(具有预期的剥离效率)到电荷状态28+,并被新谱仪(15度和30度冲击磁体)成功分离。在最高空间电荷条件下,用15 emA的40 Ar 10+离子束研究了后剥离器加速器的输运和匹配。特别是空间电荷和电荷状态相关的发射度增长效应在6d相空间将被讨论。
英文摘要:
The GSI Unilac was upgraded as a high current injector for the SIS in 1999. Therefore, the stripping section [1] at 1.4 MeV/u, where a beam transport under highest space charge conditions and multi beam operation had to be established, was completely new designed. Results of the commissioning of the stripper section will be presented. The beam transport to the new gas stripper, and the charge state analysis under space charge conditions confirmed the calculations. A 238U4+ beam - coming from a MEVVA ion source and accelerated by the new injector linac- was stripped (with the expected stripping efficiency) to the charge state 28+ and successfully separated by the new spectrometer (15 degree and 30 degree kicker magnets). The transport and matching to the poststripper accelerator under highest space charge conditions was investigated with a 15 emA 40Ar10+ beam. Especially space charge and charge state dependent emittance growth effects in 6d-phase space will be discussed.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。