海德堡诊所癌症治疗用离子束设备的7 MeV/u、217 MHz注入式直线加速器的设计

Design of the 7 MeV/u, 217 MHz Injector Linac for the Proposed Ion Beam Facility for Cancer Therapy at the Clinic in Heidelberg

B. Schlitt, A. Bechtold, U. Ratzinger, A. Schempp

摘要:

在德国海德尔堡的放射学大学,GSI为癌症治疗设计了一个专门的临床同步加速器设施,使用高能质子和离子束(C,He和O)。介绍了注入式直线加速器的设计。合适的离子源进行了讨论和离子源测试测量的结果报告。LEBT允许在两个离子源之间切换。一个短的脉冲将离子从8 keV/u加速到400 keV/u。随后是一个非常紧凑的束流匹配部分和一个3.8米长的IH型漂移管直线加速器,用于加速到7 MeV/u。这两种结构的共振频率为216.816 MHz,离子质荷比为A/q = 3(12 C4+,(H3)+,3 He+,16 O 6+)。

英文摘要:

A dedicated clinical synchrotron facility for cancer therapy using energetic proton and ion beams (C, He and O) has been designed at GSI for the Radiologische Universitaetsklinik at Heidelberg, Germany. The design of the injector linac is presented. Suitable ion sources are discussed and results of ion source test measurements are reported. The LEBT allows for switching between two ion sources. A short RFQ accelerates the ions from 8 keV/u to 400 keV/u. It is followed by a very compact beam matching section and a 3.8 m long IH-type drift tube linac for the acceleration to 7 MeV/u. Both rf structures are designed for a resonance frequency of 216.816 MHz and for ion mass-to-charge ratios up to A/q = 3 (12C4+, (H_3)+, 3He+, 16O6+).