arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2611.06664cs.CV
收藏

CardioDrift:基于形状感知相干点漂移与层移校正的3D图谱网格自动心脏运动跟踪

CardioDrift: Automatic Cardiac Motion Tracking on a 3D Atlas Mesh via Shape-aware Coherent Point Drift with Slice Shift Correction

School of Computing Science, University of Glasgow(格拉斯哥大学计算科学学院)

Reza Akbari Movahed, Abuzar Rezaee, Shatha Alamri, Edmond S. L. Ho, Fani Deligianni, Ali Gooya

AI总结:

本研究提出CardioDrift框架,通过形状感知相干点漂移结合层移校正,实现3D图谱网格的自动心脏运动跟踪,在1301名受试者及M&M数据集上的指标均优于基线方法。

摘要:

从电影式心脏磁共振(CMR)成像中自动跟踪心脏运动,对量化与心血管疾病相关的心肌运动异常至关重要。现有方法分为两类:一类表示运动时未保留受试者间的解剖对应关系,因此限制了受试者间的运动评估;另一类表示运动时采用全局对应点,但通常需要耗时且易出错的半自动步骤,以将心脏图谱适配到受试者空间。为解决这些局限,本研究提出CardioDrift,一种完全自动的基于图谱的概率框架,可在3D图谱网格上表示受试者特异性心脏运动,且采用全局对应点。该研究将相干点漂移(CPD)公式推广,以联合配准多个心脏区域的图谱表面,使其与整个心动周期内从电影式CMR分割图中提取的解剖对应轮廓相匹配。层移校正被嵌入同一概率模型中,用于估计逐层平移量,以抑制限制图谱适配精度的错位伪影。对1301名随机选取的英国生物银行(UK Biobank)受试者及M&M数据集的评估显示,CardioDrift对左心室(LV)、心肌(Myo)、右心室(RV)的戴斯相似系数(DSC)分别达92.23±8.70%、82.11±7.56%、88.69±4.13%,在两个数据集的所有距离和重叠指标上均优于最强基线方法。

英文摘要:

Automatic cardiac motion tracking from cine cardiac magnetic resonance (CMR) imaging is essential for quantifying myocardial motion abnormalities associated with cardiovascular disease. Existing methods fall into two groups: those that represent motion without anatomical correspondence across subjects and therefore limit inter-subject motion assessment; and those that represent motion with globally corresponding points, which typically require a time-consuming and error-prone semi-automatic step to fit a cardiac atlas to the subject space. To address these limitations, this study proposes CardioDrift, a fully automatic, atlas-based probabilistic framework that represents subject-specific cardiac motion on a 3D atlas mesh with globally corresponding points. The Coherent Point Drift (CPD) formulation is generalised to jointly register the atlas surfaces of multiple cardiac regions to the anatomically corresponding contours extracted from cine CMR segmentation maps throughout the cardiac cycle. Slice-shift correction is embedded in the same probabilistic model, estimating slice-wise translations that suppress the misalignment artefact limiting atlas-fitting accuracy. Evaluation on 1301 randomly selected UK Biobank subjects and the M&M dataset, CardioDrift attains Dice similarity coefficients (DSCs) of $92.23\pm8.70\%$, $82.11\pm7.56\%$, and $88.69\pm4.13\%$ for the left ventricle (LV), myocardium (Myo), and right ventricle (RV), exceeding the strongest baseline on every distance and overlap metric of both datasets.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑