Memory-Augmented Online Test-Time Adaptation for EEG Motor Imagery via Perturbation Consistency and Confidence Calibration

College of Computer Science and Technology, Zhejiang University of Technology(浙江工业大学计算机科学与技术学院)

Kunkun Zhang, Kehao Wu, Zhitao Chen, Haigen Hu, Qianwei Zhou

AI总结:

本研究提出结合扰动一致性与置信度校准的记忆增强在线测试时适应框架MOPC,在BCI IV IIb与OpenBMI数据集上分别优于现有方法2.22%、3.67%,实现了鲁棒的实时脑电运动想象解码。

摘要:

近年来,基于脑电图(EEG)的脑机接口(BCI)作为便携式神经测量系统已受到广泛关注。然而,这些设备的实际部署常受非平稳性与跨主体分布偏移的阻碍,导致显著的主体间不一致性。现有适应方法对于实时测量场景仍不实用,因为它们通常需要离线访问源数据或聚合的目标数据。为应对这些挑战,本文提出了记忆增强在线测试时适应(OTTA)方法,即结合扰动一致性与置信度校准的MOPC,这是一种无数据源的框架,旨在提升BCI设备的可靠性。MOPC使测量系统能在推理阶段动态更新解码参数,实现无需访问敏感源数据的单次通过适应。我们引入随机掩码扰动,以针对固有EEG信号噪声与采集伪影强化预测一致性。此外,设计了置信度校准重加权损失函数,用于整合特征空间相似度,有效缓解连续信号采集过程中不可靠伪标签与类别不平衡问题。为确保系统稳定性并防止已建立神经模式的灾难性遗忘,我们纳入了轻量级记忆模块,以在严格延迟预算内规范参数更新。在BCI IV IIb与OpenBMI数据集上进行评估,MOPC取得了最先进的性能,分别优于现有方法2.22%与3.67%,同时保持每次试次的适应延迟约为40-60 ms。本研究为实时EEG解码提供了一种鲁棒、无需重新校准的解决方案,标志着实用BCI测量设备的精度与可用性取得了重大进展。

英文摘要:

Recently, electroencephalography (EEG)-based brain--computer interfaces (BCIs) have gained traction as portable neural measurement systems. However, the practical deployment of these instruments is often hindered by nonstationarity and cross-subject distribution shifts, which lead to significant intersubject inconsistency. Existing adaptation methods remain impractical for real-time measurement scenarios, as they typically require offline access to source or aggregated target data. To address these challenges, this article proposes memory-augmented online test-time adaptation (OTTA) with perturbation consistency and confidence calibration (MOPC), a source-free framework designed to enhance the reliability of BCI instrumentation. MOPC enables the measurement system to update its decoding parameters on the fly during the inference stage, facilitating single-pass adaptation without accessing sensitive source data. We introduce random-mask perturbations to enforce prediction consistency against inherent EEG signal noise and acquisition artifacts. Furthermore, a confidence-calibrated reweighting loss is designed to integrate feature-space similarity, effectively mitigating unreliable pseudolabels and class imbalance during continuous signal acquisition. To ensure system stability and prevent the catastrophic forgetting of established neural patterns, a lightweight memory module is incorporated to regularize parameter updates within a tight latency budget. Evaluated on the BCI IV IIb and OpenBMI datasets, MOPC achieves state-of-the-art performance, outperforming prior methods by 2.22~\% and 3.67~\%, respectively, while keeping the per-trial adaptation latency to approximately 40--60 ms. This study provides a robust, recalibration-free solution for real-time EEG decoding, marking a significant advancement in the precision and usability of practical BCI measurement instruments.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑