arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2610.23620cs.LGeess.SP
收藏

GRAFT-EEG:用于跨数据集运动想象脑电图的尺度感知物理场传输

GRAFT-EEG: Gauge-Aware Physical Field Transport for Cross-Dataset Motor-Imagery EEG

School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University(中山大学深圳校区生物医学工程学院)

Ying Zhou, Mengting Liu

AI总结:

本研究提出GRAFT-EEG方法,针对跨数据集运动想象EEG解码的目标统计量盲迁移问题,通过移除公共参考尺度并传输原生掩码,在多数据集测试中显著提升了平衡准确率。

摘要:

跨数据集脑电图(EEG)解码通常将电极排布、参考电极及活跃传感器的变化视为表征偏移,尽管这些变化也会改变观测算子。本研究针对目标统计量盲迁移问题:拟合过程不接收任何目标信号、标签或经验统计量,仅用电极坐标实例化固定预测算子。所提方法移除活跃集公共参考尺度,并通过模板运动导联场传输每个原生掩码;源域拟合的频谱分类器作为决策锚点,有界状态空间模型(SSM)残差为辅助项。本研究确立了受限可识别性和算子扰动界。在5次留一数据集目标测试(共253名参与者)中,所提动态方法的等目标平衡准确率达60.865%,而严格干净的5/5 BIOT方法为52.684%,分层差异提升8.182个百分点(95%置信区间为+6.382至+10.196,每个目标均为正);在4次EEGPT干净目标测试中,描述性均值分别为61.520%和59.057%;在4次事后同父测试中,FULL方法较坐标基、匹配频谱、行打乱及错误解剖学对照分别提升9.959、9.698、11.241和3.985个百分点(所有95%置信区间均不含零,Holm校正后P<0.001);在60名参与者的同范式独立评估中,保留了正的物理算子对比(+4.029个百分点,95%置信区间为+2.338至+5.773),而动态-静态对比无定论,其预注册状态为部分确认而非无限制外部验证;SSM额外提升1.059个百分点(95%置信区间为+0.013至+1.892)。上述结论仅适用于5个二元运动想象域及所测试的算子。

英文摘要:

Cross-dataset EEG decoding often treats montage, reference, and active-sensor changes as representation shift, although they also alter the observation operator. We study target-statistics-blind transfer: fitting receives no target signal, label, or empirical statistic, and electrode coordinates only instantiate a fixed prediction operator. method removes the active-set common-reference gauge and transports each native mask through a template motor leadfield. A source-fitted spectral classifier anchors the decision; a bounded state-space-model (SSM) residual is secondary. We establish restricted identifiability and an operator-perturbation bound. Across five leave-one-dataset-out targets (253 participants), dynamic method achieved 60.865% equal-target balanced accuracy versus 52.684% for strict-clean 5/5 BIOT (hierarchical difference +8.182 points; 95% CI +6.382 to +10.196; positive in every target). On four EEGPT-clean targets, the descriptive means were 61.520% and 59.057%. In four post-hoc exact same-parent tests, FULL exceeded coordinate-basis, matched-spectrum, row-shuffled, and wrong-anatomy controls by 9.959, 9.698, 11.241, and 3.985 points, respectively (all 95% CIs excluded zero; Holm-adjusted P<0.001). A separate 60-participant same-paradigm evaluation retained a positive physical-operator contrast (+4.029 points; +2.338 to +5.773), whereas dynamic--static was inconclusive; its preregistered status is partial confirmation rather than unrestricted external validation. The SSM added +1.059 points (+0.013 to +1.892). Claims remain bounded to five binary motor-imagery domains and the tested operators.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑