arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2610.20848astro-ph.HEastro-ph.IM
收藏

PSR J1744-1134的脉冲抖动特性研究:迈向利用InPTA实现高精度脉冲星计时

Study of pulse jitter characteristics of PSR J1744-1134: Towards high precision pulsar timing with InPTA

Indian Institute of Technology Indore(印度印多尔理工学院);IIT Delhi(印度德里理工学院);Kumamoto University(熊本大学);IIT Hyderabad(印度海得拉巴理工学院);The Institute of Mathematical Sciences(数学科学研究所);Homi Bhabha National Institute(霍米·巴巴国立研究所);National Centre for Radio Astrophysics, SP Pune University Campus(SP浦那大学校区国家射电天体物理中心);Department of Physics, Indian Institute of Technology Roorkee(印度罗克耶理工学院物理系);Radio Astronomy Centre,Tata Institute of Fundamental Research, National Centre for Radio Astrophysics(塔塔基础研究院国家射电天体物理中心射电天文中心);Astronomy and Astrophysics Division, Physical Research Laboratory(物理研究实验室天文学与天体物理学部)
Jibin Jose, Manoneeta Chakraborty, Neelam Dhanda Batra, K Nobleson, Shantanu Desai, Manjari Bagchi, Bhal Chandra Joshi, Keitaro Takahashi, Shaswata Chowdhury, C… 展开作者

Jibin Jose, Manoneeta Chakraborty, Neelam Dhanda Batra, K Nobleson, Shantanu Desai, Manjari Bagchi, Bhal Chandra Joshi, Keitaro Takahashi, Shaswata Chowdhury, Churchil Dwivedi, Abhimanyu Susobhanan, Debabrata Deb, Sushovan Mondal, Zenia Zuraiq, Kaustubh Rai, Sharika Dhakappa, Pratik Tarafdar, Kuldeep Meena

AI总结:

本研究利用InPTA的观测数据,首次在300-500 MHz频段详细研究PSR J1744-1134的脉冲抖动特性,明确其抖动信号、频率演化特征,且发现抖动不限制该星的色散量精度,为提升脉冲星计时精度提供支撑。

摘要:

单个脉冲的形状变化会在脉冲星到达时间中引入超出辐射计噪声预期的宽带噪声分量,该分量被称为抖动噪声。这种噪声限制了计时精度,进而限制了利用脉冲星计时阵列探测纳赫兹引力波所需的灵敏度。因此,对每颗脉冲星的抖动噪声(包括其振幅和频率依赖性)进行精确表征至关重要。本研究利用升级后的巨型米波射电望远镜开展的印度脉冲星计时阵列(InPTA)实验观测,首次在300-500 MHz频率范围内对PSR J1744-1134的抖动噪声进行了详细研究。我们通过脉冲级分析和贝叶斯推断在该脉冲星中检测到了明确的抖动信号。此外,我们还研究了抖动噪声的频率依赖性,并将结果与更高频率下的早期测量结果进行了比较。观测到的抖动振幅差异表明可能存在频率演化,凸显了低频研究对提高脉冲星计时精度和准确度的重要性。我们还研究了抖动对从观测中推导的高精度色散量(DM)的影响,发现在给定观测时间尺度下,抖动并非该脉冲星DM精度的限制因素。

英文摘要:

Variations in the shapes of individual pulses introduce a broadband noise component in pulsar times of arrival beyond what is expected from radiometer noise, referred to as the jitter noise. This noise limits the timing accuracy and, consequently, the sensitivity required for the detection of nanohertz gravitational waves using pulsar timing arrays. Accurate characterization of jitter noise, including its amplitude and frequency dependence, is therefore essential for each pulsar. In this work, we present the first detailed study of jitter noise in PSR J1744-1134 over the frequency range 300-500 MHz, using observations from the Indian Pulsar Timing Array experiment conducted with the upgraded Giant Metrewave Radio Telescope. We detect clear signatures of jitter in this pulsar through pulse-level analysis and Bayesian inference. Furthermore, we investigated the frequency dependence of the jitter noise and compared our results with earlier measurements at higher frequencies. The observed differences in jitter amplitude suggest a possible frequency evolution, highlighting the importance of low-frequency studies for improving pulsar timing precision and accuracy. We also investigated the effect of jitter on the high precision dispersion measure derived from our observations and found that jitter is not the limiting factor for DM precision achieved for this pulsar in the given observation timescale.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑