arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2407.19615astro-ph.HEastro-ph.IM
收藏

利用单脉冲流量聚类提高脉冲星计时精度

Improving Pulsar Timing Precision with Single Pulse Fluence Clustering

Sofia V. Sosa Fiscella, Michael T. Lam, Maura A. McLaughlin

AI总结:

本研究提出一种基于单脉冲流量聚类的脉冲星计时方法,通过分类不同状态的单脉冲并分别计时,有效降低了PSR J2145-0750在820 MHz和1400 MHz频段的TOA不确定度,提升了计时精度。

摘要:

传统的脉冲星计时技术涉及对大量单脉冲进行平均以获得高信噪比(S/N)剖面,并将其与模板匹配以测量到达时间(TOA)。然而,由于脉冲抖动,单个单脉冲的形态变化很大。不同流量的脉冲对平均脉冲的S/N贡献不同。我们的研究提出了一种方法,通过识别一系列状态并分别对每种状态进行计时来考虑这些变化。我们选取了PSR J2145-0750的两次1小时观测,每次观测使用Green Bank Telescope在不同频段进行。我们将脉冲幅度归一化以考虑闪烁效应,并探索了不同的剔除算法以减少射频干扰。然后,我们测量了四个脉冲参数(幅度、位置、宽度和能量),使用自动聚类算法对单脉冲进行分类。对于每个聚类,我们计算了平均脉冲剖面和模板,并使用两者来获得TOA和TOA误差。最后,我们计算了加权平均TOA和TOA误差,后者作为该历元总计时精度的指标。相对于未使用聚类获得的TOA,该TOA发生了偏移,并且我们可以使用相同的数据通过这种加权来估计偏移量。对于820 MHz和1400 MHz频段,我们获得的TOA不确定度分别为0.057微秒和0.46微秒,而在未应用聚类时分别为0.066微秒和0.74微秒。我们得出结论,针对该方法进行定制可能有助于提高NANOGrav数据集中某些明亮脉冲星的计时精度。

英文摘要:

Traditional pulsar timing techniques involve averaging large numbers of single pulses to obtain a high signal-to-noise (S/N) profile, which is matched to a template to measure a time of arrival (TOA). However, the morphology of individual single pulses varies greatly due to pulse jitter. Pulses of different fluence contribute differently to the S/N of the pulse average. Our study proposes a method that accounts for these variations by identifying a range of states and timing each separately. We selected two 1-hour observations of PSR J2145-0750, each in a different frequency band with the Green Bank Telescope. We normalized the pulse amplitudes to account for scintillation effects and probed different excision algorithms to reduce radio-frequency interference. We then measured four pulse parameters (amplitude, position, width, and energy) to classify the single pulses using automated clustering algorithms. For each cluster, we calculated an average pulse profile and template and used both to obtain a TOA and TOA error. Finally, we computed the weighted average TOA and TOA error, the latter as a metric of the total timing precision for the epoch. The TOA is shifted relative to the one obtained without clustering, and we can estimate the shift with this weighting using the same data. For the 820 MHz and 1400 MHz bands, we obtained TOA uncertainties of 0.057 microseconds and 0.46 microseconds, compared to 0.066 microseconds and 0.74 microseconds when no clustering is applied. We conclude that tailoring this method could help improve the timing precision for certain bright pulsars in NANOGrav's dataset.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑