心电图基础模型能否迁移到罕见心脏疾病?来自Brugada综合征检测的证据
Do ECG Foundation Models Transfer to Rare Cardiac Diseases? Evidence from Brugada Syndrome Detection
AI总结:
研究通过在两个队列上评估九种心电图基础模型,探讨其对罕见病检测的作用,采用多种策略和配置,发现预训练对某些架构必要但效果有限,挑战了大规模预训练能编码有意义表征的假设。
摘要:
背景:基于大规模未标记生理数据训练的基础模型已成为医学人工智能的一种有前景的范式。它们捕捉罕见病临床有意义、可转移表征的能力在很大程度上仍未得到证实。本研究调查基础模型预训练是否能提供真正的临床泛化益处,而不仅仅是针对罕见心电图表型改进优化。方法:我们在BrSwiss队列(294例患者,87例病例)和独立的外部HUCA队列(363例患者,76例病例)上,在三种策略(从头开始训练、线性探测、完全微调)下,对九种公开可用的心电图基础模型进行Brugada综合征检测系统评估,包括3%数据消融和零样本跨站点转移的几种配置。结果:预训练对于无法从头开始收敛的高容量架构是必要的(AUC增益高达0.411,p<0.05),但对于仅在标记数据上已收敛的紧凑架构没有显著增益。在完整的BrSwiss上,最佳微调基础模型(ECG-CPC,AUC = 0.962)仅略微超过最强的监督基线(从头开始的ECG-CPC,AUC = 0.932;p = 0.091)。在匹配的训练集大小下,BrSwiss-3%上的数据效率优势(AUC增益 = 0.055,p<0.01)在HUCA上没有重现。在零样本跨站点转移下,基于基础模型的管道没有比监督基线更好地泛化,所有都接近机会水平性能。结论:对于Brugada综合征检测,基础模型预训练是机械的而非语义的,提供优化稳定性而非可转移的临床知识。这些发现挑战了大规模预训练固有地编码临床有意义表征的假设,突出了模型架构和数据域对齐的核心作用。
英文摘要:
Background: Foundation models (FMs) trained on large-scale unlabeled physiological data have emerged as a promising paradigm for medical artificial intelligence. Their ability to capture clinically meaningful, transferable representations for rare diseases remains largely unproven. This study investigates whether FM pre-training provides genuine clinical generalization benefits beyond improved optimization for rare electrocardiographic (ECG) phenotypes. Methods: We systematically evaluated nine publicly available ECG FMs for Brugada syndrome detection on the BrSwiss cohort (294 patients, 87 cases) and the independent external HUCA cohort (363 patients, 76 cases), under three strategies (from-scratch training, linear probing, full fine-tuning) across several configurations, including a 3% data ablation and zero-shot cross-site transfers. Results: Pre-training was necessary for high-capacity architectures unable to converge from scratch (AUC gain up to 0.411, p < 0.05), but gave no significant gain for compact architectures already converged on labeled data alone. On full BrSwiss, the best fine-tuned FM (ECG-CPC, AUC = 0.962) only marginally exceeded the strongest supervised baseline (ECG-CPC from scratch, AUC = 0.932; p = 0.091). At matched training-set size, the data-efficiency advantage on BrSwiss-3% (AUC gain = 0.055, p < 0.01) did not replicate on HUCA. Under zero-shot cross-site transfer, FM-based pipelines did not generalize better than supervised baselines, all approaching chance-level performance. Conclusion: For Brugada syndrome detection, FM pre-training is mechanical rather than semantic, providing optimization stability rather than transferable clinical knowledge. These findings challenge the assumption that large-scale pre-training inherently encodes clinically meaningful representations, highlighting the central role of model architecture and data-domain alignment.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。