arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2605.30952cs.LG
收藏

量子高斯过程核的谱解剖

Spectral Anatomy of Quantum Gaussian Process Kernels

RIKEN iTHEMS;RIKEN AIP;South China University of Technology(华南理工大学);Columbia University(哥伦比亚大学)

Jian Xu, Chao Li, Guang Lin, Yuning Qiu, Delu Zeng, John Paisley, Qibin Zhao

AI总结:

通过归一化谱熵S(K)/log n统一解释了量子高斯过程回归中指数加速失效与后验病理现象,并证明该诊断量在多种量子与经典核上具有普适性,且在IBM Heron硬件上实现了低误差迁移。

摘要:

两个近期结果重塑了量子高斯过程(QGPs)。一方面,\citet{lowe2025assessing} 排除了在典型、良态条件下基于HHL的QGP回归声称的指数加速;另一方面,一项独立工作表明,高表达性量子核存在后验病理,破坏了贝叶斯优化。我们证明这些看似无关的现象由同一个量控制:核Gram矩阵的归一化谱熵 $S(K)/\log n$。我们证明了Nyström近似误差的Cauchy–Schwarz尾部界、以Bach自由度 $d_σ(K)$ 表示的有限样本方差收缩恒等式,以及通过目标在核本征基中的内在维数对 \emph{依赖于目标} 的最优熵的表征。实验上,该诊断量与核无关:硬件高效、matchgate、IQP \emph{以及} RBF/Matérn/RFF/深度核族在去量子化、ECE和方差收缩面板上全部坍缩到相同的 $S/\log n$ 曲线上。NLL最佳点位于光滑目标的高熵和带限量子数据目标的低熵。该诊断量从模拟器迁移到IBM Heron硬件,在 $n_q = 4$ 的 $24$ 种配置中 $S/\log n$ 的中位绝对误差为 $3.2\%$,平均误差为 $5.2\%$,其中matchgate和IQP的平均误差在 $5\%$ 以内,单个HE配置返回 $30\%$ 的异常值,重新运行时降至 $0.5\%$(归因于校准漂移);相同的诊断量迁移到第二个Heron后端(平均误差 $2.7\%$)以及原始后端上的 $n_q = 6$ 扩展(平均误差 $1.7\%$)。全程未应用误差缓解。

英文摘要:

Two recent results have reshaped quantum Gaussian processes (QGPs). On the one hand, \citet{lowe2025assessing} rule out the exponential speedups claimed by HHL-based QGP regression in the typical, well-conditioned regime; on the other, an independent line of work shows that highly expressive quantum kernels suffer posterior pathologies that break Bayesian optimization. We show that these seemingly unrelated phenomena are governed by the same quantity: the normalized spectral entropy $S(K)/\log n$ of the kernel Gram matrix. We prove a Cauchy--Schwarz tail bound on Nyström approximation error, a finite-sample variance-contraction identity in terms of Bach's degrees of freedom $d_σ(K)$, and a characterization of the \emph{target-dependent} optimal entropy via the intrinsic dimension of the target in the kernel eigenbasis. Empirically, the diagnostic is kernel-agnostic: hardware-efficient, matchgate, IQP \emph{and} RBF/Matérn/RFF/deep-kernel families all collapse onto identical $S/\log n$ curves on dequantization, ECE, and variance-contraction panels. The NLL sweet spot lives at high entropy for smooth targets and at low entropy for band-limited quantum-data targets. The diagnostic transfers from simulator to IBM Heron hardware with median absolute error $3.2\%$ and mean $5.2\%$ in $S/\log n$ across $24$ configurations at $n_q = 4$, with matchgate and IQP within $5\%$ mean and a single HE configuration returning a $30\%$ outlier that drops to $0.5\%$ on rerun (attributed to calibration drift); the same diagnostic transfers to a second Heron backend (mean error $2.7\%$) and to a $n_q = 6$ scale-up on the original backend (mean error $1.7\%$). No error mitigation is applied throughout.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑