arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2604.23047physics.med-ph
收藏

对开源FDK与商业及迭代重建方法在临床前微CT中的性能评估

Benchmarking Open-Source FDK Against Commercial and Iterative Reconstruction Methods for Preclinical Micro-CBCT

The University of British Columbia(不列颠哥伦比亚大学)

Falk L Wiegmann, Nancy L Ford

AI总结:

本文对比了四种重建方法在相同数据上的性能,发现单一指标排名误导性大,开源FDK在速度和透明度上表现优异,而商业软件在空间分辨率上最佳但低对比度检测能力不足。

摘要:

临床前微CT重建涉及大投影尺寸和体积,使迭代方法成本高昂,比分析方法慢5到50倍。是否值得这种成本取决于成像任务,但缺乏基于任务的指标的直接比较。本文在相同的eXplore CT 120微CT扫描仪数据上评估了四种重建方法:开源FDK管道、专有软件、以及两个迭代工具箱ASTRA SIRT和TIGRE OS-SART。使用调制传递函数(MTF)、噪声功率谱(NPS)和非预白化检测指数(NPW d'),结果显示单一指标排名具有误导性:专有软件在空间分辨率(MTF10=2.96 lp/mm)上最高,但未能达到Rose标准(d'=3)在半扫描采集中。ASTRA SIRT在计算时间是FDK的5倍,提供最佳低对比度检测能力,而TIGRE OS-SART在成本是FDK的50倍时无额外好处且在不同扫描协议中不稳定。对于高对比度任务,所有方法表现相似。我们发布开源FDK管道作为软件,提供快速、透明且可集成的重建工具。

英文摘要:

Preclinical micro-CT reconstruction involves large projection sizes and volumes that make iterative methods costly - 5x to 50x slower than analytic alternatives on modern GPUs. Whether this cost is justified depends on the imaging task, yet head-to-head comparisons using task-based metrics on identical preclinical data are lacking. We benchmark four reconstruction methods on identical acquisitions from an eXplore CT 120 micro-CT scanner (Trifoil Imaging, USA): an open-source Feldkamp-Davis-Kress (FDK) pipeline, the proprietary vendor software, and two iterative toolboxes at default settings - ASTRA SIRT and TIGRE OS-SART. Using the modulation transfer function (MTF), noise power spectrum (NPS), and non-prewhitening detectability index (NPW d'), we show that single-metric rankings are misleading: the vendor software achieves the highest spatial resolution ($\mathrm{MTF}_{10} = 2.96$ lp/mm) but fails to reach the Rose criterion ($d'=3$) for 100 HU contrast objects on a half-scan acquisition. ASTRA SIRT, at 5x the computation time of FDK, provides the best low-contrast detectability, while TIGRE OS-SART at 50x the cost offers no additional benefit and exhibits instability across scan protocols. For high-contrast tasks, all methods perform comparably. We release our FDK pipeline as open-source software, providing a fast, transparent, and integrable reconstruction tool for the preclinical micro-CT community.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑