arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2603.26255cond-mat.mes-hallquant-ph
收藏

关于在电子自旋共振扫描隧道显微镜中Hahn回波测量的解释

On the interpretation of Hahn echo measurements in electron spin resonance scanning tunneling microscopy

Karlsruhe Institute of Technology(卡尔斯鲁厄理工学院);Institute for Basic Science(基础科学研究院);Ewha Womans University(梨花女子大学)

Paul Greule, Wantong Huang, Máté Stark, Kwan Ho Au-Yeung, Christoph Wolf, Soo-hyon Phark, Andreas J. Heinrich, Philip Willke

AI总结:

本文研究了电子自旋共振扫描隧道显微镜中Hahn回波测量的解释问题,指出RF电压导致的隧道电子影响了回波信号的相干性,并提出通过调整延迟时间以确保信号的相干性。

摘要:

电子自旋共振扫描隧道显微镜(ESR-STM)已成为研究表面单个原子和分子自旋动力学和相干性的强大工具。本文通过ESR-STM对MgO/Ag(001)表面的单个铁酞菁(FePc)分子进行Rabi振荡和Hahn回波脉冲协议。尽管Hahn回波协议广泛用于提取自旋相干时间,但我们显示在ESR-STM中,由于应用的射频(RF)电压产生的隧道电子,这些协议特别容易被误解释。RF电压不仅驱动自旋,同时探测并使其弛豫,这导致指数衰减反映自旋弛豫而非内在相位相干性。我们还显示,改变回波脉冲序列中的延迟时间是确保回波信号相干性的可靠方法。后者的协议提取的衰减表明T2约为30 ns,因此更接近Rabi振荡测量中观察到的退相干时间。这比先前回波测量中报告的值显著短。我们的发现强调了在ESR-STM中解释Hahn回波和Carr-Purcell协议的T2时间时需要谨慎,并提供了区分真实自旋回波信号和隧道诱导弛豫信号的实用标准。

英文摘要:

Electron spin resonance scanning tunneling microscopy (ESR-STM) has become a powerful tool for probing spin dynamics and coherence of individual atoms and molecules on surfaces. In this work, we perform Rabi oscillation and Hahn echo pulse protocols on individual iron phthalocyanine (FePc) molecules on MgO/Ag(001) using ESR-STM. While Hahn echo protocols are widely used to extract spin coherence times, we show that in ESR-STM they are particularly susceptible to misinterpretation due to tunneling electrons generated by the applied radio-frequency (RF) voltage. The RF voltage not only drives the spin, but simultaneously probes and relaxes it, which consequently leads to an exponential decay that reflects spin relaxation rather than intrinsic phase coherence. We moreover show that varying both delay times in the refocusing pulse sequence is a reliable way to ensure a coherent nature of the echo signal. The extracted decay for the latter protocol suggests that T2 is approximately 30 ns and is thus closer to the decoherence time observed in Rabi oscillation measurements. This is significantly shorter than values reported in previous echo measurements. Our findings underscore the need for caution in interpreting T2 times from Hahn echo and Carr-Purcell protocols in ESR-STM and provide practical criteria for distinguishing true spin echoes from tunneling-induced relaxometry signals.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑