Design of a high voltage delivery system for noble liquid time projection chambers
Pacific Northwest National Laboratory(太平洋西北国家实验室);TAE Technologies(TAE技术公司);Stanford University(斯坦福大学);Lawrence Livermore National Laboratory(劳伦斯利弗莫尔国家实验室);Canadian Nuclear Laboratories(加拿大核实验室);Carleton University(卡尔顿大学);SLAC National Accelerator Laboratory(SLAC国家加速器实验室);University of Bern(伯尔尼大学);ETH Zürich(苏黎世联邦理工学院)
R. Saldanha, L. Pagani, E. Angelico, E. P. Bernard, B. Chana, S. Delaquis, R. DeVoe, M. Elbeltagi, S. Ferrara, D. Goeldi, R. Gornea, A. Odian, G. S. Ortega, C. … 展开作者
R. Saldanha, L. Pagani, E. Angelico, E. P. Bernard, B. Chana, S. Delaquis, R. DeVoe, M. Elbeltagi, S. Ferrara, D. Goeldi, R. Gornea, A. Odian, G. S. Ortega, C. T. Overman, L. Placzek, P. C. Rowson, K. Skarpaas, F. Spadoni, P. Acharya, A. Amy, A. Anker, I. J. Arnquist, A. Atencio, J. Bane, V. Belov, T. Bhatta, A. Bolotnikov, J. Breslin, P. A. Breur, E. Brown, T. Brunner, B. Burnell, E. Caden G. F. Cao, L. Q. Cao, D. Cesmecioglu, D. Chernyak, M. Chiu, R. Collister, M. Marquis, T. Daniels, L. Darroch, M. L. di Vacri, Y. Y. Ding, M. J. Dolinski, B. Eckert, A. Emara, N. Fatemighomi, W. Fairbank, B. Foust, D. Gallacher, N. Gallice, A. Gaur, W. Gillis, F. Girard, G. Gratta, C. A. Hardy, S. Hedges, E. Hein, J. D. Holt, A. Iverson, X. S. Jiang, A. Karelin, D. Keblbeck, A. Kuchenkov, K. S. Kumar, A. Larson, M. B. Latif, S. Lavoie, K. G. Leach, B. G. Lenardo, K. K. H. Leung, H. Lewis, G. Li, X. Li, Z. Li, C. Licciardi, R. Lindsay, R. MacLellan, S. Majidi, J. Masbou, M. Medina-Peregrina, S. Mngonyama, B. Mong, D. C. Moore, K. Ni, I. Nitu, A. Nolan, S. C. Nowicki, J. C. Nzobadila Ondze, J. L. Orrell, A. Pena-Perez, H. Peltz Smalley, A. Piepke, A. Pocar, E. Raguzin, R. Rai, H. Rasiwala, D. Ray, S. Rescia, F. Retiere, G. Richardson, V. Riot, N. Rocco, R. Ross, S. Sangiorgio, S. Sekula, T. Shetty, L. Si, V. Stekhanov, X. L. Sun, S. Thibado, T. Totev, S. Triambak, R. H. M. Tsang, O. A. Tyuka, E. van Bruggen, M. Vidal, S. Viel, Q. D. Wang, M. Watts, W. Wei, M. Wehrfritz, L. J. Wen, S. Wilde, M. Worcester, X. M. Wu, H. Xu, H. B. Yang, L. Yang, M. Yu, O. Zeldovich, J. Zhao
Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This paper addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.
Calibration Plan for the SBC 10-kg Liquid Argon Detector with 100 eV Target Threshold
University of Alberta(阿尔伯塔大学);University of California Riverside(加州大学河滨分校);University of California Santa Barbara(加州大学圣塔芭芭拉分校);Drexel University(德雷塞尔大学);Fermi National Accelerator Laboratory(费米国家加速器实验室);Indiana University South Bend(南本德印第安纳大学);Northeastern Illinois University(伊利诺伊东北大学);Northwestern University(西北大学);Queen's University(女王大学);SNOLAB(斯诺实验室)
High Voltage Delivery and Distribution for the NEXT-100 Time Projection Chamber
Argonne National Laboratory(阿贡国家实验室);Donostia International Physics Center(圣塞巴斯蒂安国际物理中心);Manchester University(曼彻斯特大学);University of Texas at Arlington(德克萨斯大学阿灵顿分校);Ben-Gurion University of the Negev(内盖夫本-古里安大学);Pacific Northwest National Laboratory (PNNL)(太平洋西北国家实验室);Universidad del Pais Vasco (UPV/EHU)(巴斯克地区大学);Universidade de Aveiro(阿威罗大学);University of Coimbra(科英布拉大学);Iowa State University(爱荷华州立大学);The Hebrew University of Jerusalem(耶路撒冷希伯来大学);Fermi National Accelerator Laboratory(费米国家加速器实验室)
Physics-informed continuous normalizing flows to learn the electric field within a time-projection chamber
William Marsh Rice University(莱斯大学);SLAC National Accelerator Laboratory, Stanford University(斯坦福大学SLAC国家加速器实验室);Kavli Institute for Particle Astrophysics and Cosmology, Stanford University(斯坦福大学卡弗里粒子天体物理与宇宙学研究所);Vatican Observatory(梵蒂冈天文台)
Commissioning and first results from the Cold Radon Emanation Facility
University College London (UCL)(伦敦大学学院);Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室);STFC Rutherford Appleton Laboratory (RAL)(英国科学与技术设施委员会卢瑟福阿普尔顿实验室)
Detection of scintillation light in noble gases with wavelength-shifting optical fibers
Donostia International Physics Center, BERC Basque Excellence Research Centre(多诺西亚国际物理中心,BERC巴斯克卓越研究中心);Ikerbasque (Basque Foundation for Science)(伊克拉巴斯克(巴斯克科学基金会));Instituto de Física Corpuscular (IFIC), CSIC & Universitat de València(粒子物理研究所(IFIC),西班牙国家研究委员会与瓦伦西亚大学);Department of Physics, Universidad del Pais Vasco (UPV/EHU)(巴斯克国立大学(UPV/EHU)物理系);Nuclear Research Center Negev(内盖夫核研究中心)
Charge and Light Production in the Charge Readout System of a Dual Phase LAr TPC
对于未来的中微子振荡实验DUNE,预计每个基准质量为10千吨的液氩时间投影室。双相概念是所考虑的两种实现方式之一,其中,由液体中的电离产生的电子被提取到液体上方的气体区域,在该气体区域中,电子被放大。为了放大,将使用大型电子倍增器。该技术在各种原型中进行了测试,最近使用的是3 x 1 x 1 m $^3$大型装置。目前正在建造一个更大的6 x 6 x 6 m $^3$原型,并将于2019年开始运营。进行了密集的研发计划,重点是实现至少20的有效增益。在这里首次提出的模拟研究中,不仅考虑了电子信号,而且还研究了离子回流和二次闪烁光的预期产生,因为后者可能限制探测器触发低能量无束物理的能力。发现离子回流和光产额可以预期非常大。有效增益的结果显示出与实验数据的差异,无论是在大小和形状的增益曲线。基于文献研究,认为光子反馈对填充纯稀有气体的探测器的增益有贡献,特别是在纯氩的情况下。