惰性液体时间投影室阴极线寄生电子发射的研究与抑制

Study and mitigation of spurious electron emission from cathodic wires in noble liquid time projection chambers

A. Tomás, H. M. Araújo, A. J. Bailey, A. Bayer, E. Chen, B. López Paredes, T. J. Sumner

摘要:

贵金属液体辐射探测器的阴极电极产生的假电子发射一直困扰着探测器。在寻找弱相互作用暗物质或无中微子双β衰变的下一代液体氙(LXe)实验中,以及在用于长基线中微子计划的大型液体氩(LAr)探测器中,必须理解和减轻这种现象。我们提出了一个系统的研究,这种杂散发射涉及一系列的缓慢的电压斜坡测试细金属线浸没在一个两相氙时间投影室与单电子灵敏度。因此,通过电子计数可以检测到低至$10^{-18}$ A的发射电流,这是对以前专用测量的巨大改进。在某些导线中,在低至$\sim$ 10 kV/cm的表面场记录到发射事件,并观察到具有复杂的发射模式,平均速率为10-200计数每秒(c/s),爆发高达$\sim$ 10 $^6$ c/s。在所有未处理的样品中也存在较暗、可变性较小的发射类型。有证据表明部分调节效应,随后的测试平均产生更少的发射器发生在不同的领域相同的电线。我们没有发现一个固有的阈值特定的金属-Leptin界面,这可能限制了以前的实验,至少160千伏/厘米的领域的证据。一般的现象是不一致的增强场发射从微观灯丝,但它似乎,而不是相关的腐蚀和其氧化层的性质方面的线表面的质量。这项研究的结论是,一些表面处理,特别是硝酸清洗不锈钢丝,可以带来至少一个数量级的整体电子发射率的改善,这应该有助于下一代探测器实现所需的静电性能。

英文摘要:

Noble liquid radiation detectors have long been afflicted by spurious electron emission from their cathodic electrodes. This phenomenon must be understood and mitigated in the next generation of liquid xenon (LXe) experiments searching for WIMP dark matter or neutrinoless double beta decay, and in the large liquid argon (LAr) detectors for the long-baseline neutrino programmes. We present a systematic study of this spurious emission involving a series of slow voltage-ramping tests on fine metal wires immersed in a two-phase xenon time projection chamber with single electron sensitivity. Emission currents as low as $10^{-18}$ A can thus be detected by electron counting, a vast improvement over previous dedicated measurements. Emission episodes were recorded at surface fields as low as $\sim$10 kV/cm in some wires and observed to have complex emission patterns, with average rates of 10-200 counts per second (c/s) and outbreaks as high as $\sim$10$^6$ c/s. A fainter, less variable type of emission was also present in all untreated samples. There is evidence of a partial conditioning effect, with subsequent tests yielding on average fewer emitters occurring at different fields for the same wire. We find no evidence for an intrinsic threshold particular to the metal-LXe interface which might have limited previous experiments up to fields of at least 160 kV/cm. The general phenomenology is not consistent with enhanced field emission from microscopic filaments, but it appears instead to be related to the quality of the wire surface in terms of corrosion and the nature of its oxide layer. This study concludes that some surface treatments, in particular nitric acid cleaning for stainless steel wires, can bringing about at least order-of-magnitude improvements in overall electron emission rates, and this should help the next generation of detectors achieve the required electrostatic performance.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑