arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2602.18663cs.ROcs.LG
收藏

迈向机械取栓的AI自主导航:基于分层模块多智能体强化学习(HM-MARL)

Toward AI Autonomous Navigation for Mechanical Thrombectomy using Hierarchical Modular Multi-agent Reinforcement Learning (HM-MARL)

Harry Robertshaw, Nikola Fischer, Lennart Karstensen, Benjamin Jackson, Xingyu Chen, S. M. Hadi Sadati, Christos Bergeles, Alejandro Granados, Thomas C Booth

AI总结:

本研究提出分层模块多智能体强化学习框架,实现机械取栓中双设备自主导航,展示体外导航能力及泛化挑战。

摘要:

机械取栓(MT)通常是治疗急性缺血性中风涉及大血管闭塞的最佳治疗方式,但受限于地理和后勤障碍。强化学习(RL)在自主血管内导航中显示出前景,但跨'长'导航任务的泛化仍具挑战性。我们提出了一种分层模块多智能体强化学习(HM-MARL)框架,用于体外自主双设备导航,实现了高效且可泛化的导航。HM-MARL被开发用于自主导航引导导管和导丝从股动脉到颈内动脉(ICA)。采用模块化多智能体方法将复杂导航任务分解为专门的子任务,每个子任务均使用软演员评论家RL进行训练。该框架在体素和体外测试床上验证,以评估泛化能力和现实可行性。在体素中,单血管模型在个体解剖结构上实现了92-100%的成功率,而多血管模型在多个患者解剖结构上实现了56-80%的成功率。在体外,两种HM-MARL模型均成功将100%的试验从股动脉导航到右侧颈总动脉,并在80%的试验中导航到右侧ICA,但因导航中使用的解剖和导管类型而失败了左侧血管超人挑战。本研究首次展示了在MT血管中的体外自主导航。尽管HM-MARL能够跨解剖结构泛化,但仿真到现实的过渡引入了挑战。未来的工作将通过世界模型优化RL策略,并在未见过的体外数据上验证性能,推动自主MT向临床应用迈进。

英文摘要:

Mechanical thrombectomy (MT) is typically the optimal treatment for acute ischemic stroke involving large vessel occlusions, but access is limited due to geographic and logistical barriers. Reinforcement learning (RL) shows promise in autonomous endovascular navigation, but generalization across 'long' navigation tasks remains challenging. We propose a Hierarchical Modular Multi-Agent Reinforcement Learning (HM-MARL) framework for autonomous two-device navigation in vitro, enabling efficient and generalizable navigation. HM-MARL was developed to autonomously navigate a guide catheter and guidewire from the femoral artery to the internal carotid artery (ICA). A modular multi-agent approach was used to decompose the complex navigation task into specialized subtasks, each trained using Soft Actor-Critic RL. The framework was validated in both in silico and in vitro testbeds to assess generalization and real-world feasibility. In silico, a single-vasculature model achieved 92-100% success rates on individual anatomies, while a multi-vasculature model achieved 56-80% across multiple patient anatomies. In vitro, both HM-MARL models successfully navigated 100% of trials from the femoral artery to the right common carotid artery and 80% to the right ICA but failed on the left-side vessel superhuman challenge due to the anatomy and catheter type used in navigation. This study presents the first demonstration of in vitro autonomous navigation in MT vasculature. While HM-MARL enables generalization across anatomies, the simulation-to-real transition introduces challenges. Future work will refine RL strategies using world models and validate performance on unseen in vitro data, advancing autonomous MT towards clinical translation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑