在WISArD实验高磁场中利用微通道板探测器进行高精度束流剖面测量

High-precision beam profile measurement with a microchannel-plate detector in the high magnetic field of the WISArD experiment

Université de Bordeaux, CNRS/IN2P3, LP2i Bordeaux UMR5797(波尔多大学);Université de Caen Normandie, ENSICAEN, CNRS/IN2P3, LPC Caen UMR6534(卡昂诺曼底大学);Belgian Nuclear Research Centre SCK-CEN(比利时核研究中心SCK-CEN);Center for Exotic Nuclear Studies, Institute for Basic Science(基础科学研究院奇异核研究数据中心);KU Leuven, Instituut voor Kern- en Stralingsfysica(荷语鲁汶大学)
S. Lecanuet, X. Fléchard, P. Alfaurt, P. Ascher, D. Atanasov, B. Blank, L. Daudin, H. DePreaumont, M. Gerbaux, J. Giovinazzo, S. Grévy, G. Guignard, J. Ha, C. K… 展开作者

S. Lecanuet, X. Fléchard, P. Alfaurt, P. Ascher, D. Atanasov, B. Blank, L. Daudin, H. DePreaumont, M. Gerbaux, J. Giovinazzo, S. Grévy, G. Guignard, J. Ha, C. Knapen, S. Lechner, A. Lépine, J. Lory, J. Perronnel, M. Pomorski, M. Roche, C. Roumegou, N. Severijns, Y. Son, S. Vanlangendonck, M. Versteegen, D. Zakoucky

AI总结:

利用微通道板探测器在高磁场环境下实现高精度束流剖面测量,满足WISArD实验对β中微子角相关系数的精度要求。

摘要:

我们介绍了为ISOLDE/CERN的WISArD(利用氩-32衰变研究弱相互作用)实验开发和表征的紧凑型低能离子束诊断装置。该微通道板(MCP)探测器配置为Z堆栈,并具有电阻位置敏感阴极,已分别用稳定束和放射性束进行了测试。本工作聚焦于图像重建方法,该方法修正了正方形电阻阴极固有的桶形失真,并研究了磁场对探测器性能的影响。我们的结果表明,探测器在满足实验的空间和高磁场(4 T)约束条件下,能够实现亚毫米级的束流剖面测量。这些能力满足了WISArD实验对提取修正的β中微子角相关系数ã_βν的精度要求,其不确定度为0.1%。

英文摘要:

We present the development and characterization of a compact low-energy ion beam diagnostic for the WISArD (Weak Interaction Studies with $\mathrm{^{32}Ar}$ Decay) experiment at ISOLDE/CERN. The microchannel plate (MCP) detector, which is configured in a Z-stack and has a resistive position sensitive anode, was tested with both stable and radioactive beams. This work focuses on the image reconstruction method, which corrects the pincushion distortion inherent to the square-shaped resistive anode, and investigates the influence of the magnetic field on the detector performance. Our results demonstrate that the detector achieves beam profile measurements with sub-millimeter accuracy, while coping with the spatial and high-magnetic field (4 T) constraints of the experiment. These capabilities meet the precision requirements of the WISArD experiment for extracting the modified beta-neutrino angular correlation coefficient, ã$_{βν}$, with an uncertainty of 0.1%.