arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2602.06761eess.IVcs.CV

具有鲁棒性的潜在运动轨迹学习用于胎儿超声心动图中无需标注的心脏相位检测

Orientation-Robust Latent Motion Trajectory Learning for Annotation-free Cardiac Phase Detection in Fetal Echocardiography

Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford(生物医学工程研究所,工程科学系,牛津大学);Nuffield Department of Women’s and Reproductive Health, University of Oxford(妇女与生殖健康纽菲尔德部门,牛津大学)

Yingyu Yang, Qianye Yang, Can Peng, Elena D'Alberti, Olga Patey, Aris T. Papageorghiou, J. Alison Noble

AI总结:

ORBIT通过自监督学习在无标注情况下实现胎儿超声心动图中心脏相位的鲁棒检测。

摘要:

胎儿超声心动图对于检测先天性心脏病(CHD)至关重要,有助于孕期管理、优化分娩计划以及及时的出生后干预。在标准成像平面中,四腔(4CH)视图为CHD诊断提供了全面的信息,其中临床医生仔细检查舒张末期(ED)和收缩末期(ES)阶段以评估心脏结构和运动。因此,自动检测这些心脏阶段是实现全自动CHD分析的关键组成部分。然而,在没有胎儿心电图(ECG)的情况下,手动识别ED和ES帧仍是一个劳动密集型的瓶颈。我们提出了ORBIT(从轨迹中鲁棒地推断心跳),这是一个自监督框架,能够在各种胎儿心脏方向下无需手动标注地识别心脏阶段。ORBIT将配准作为自监督任务,并学习心脏变形的潜在运动轨迹,其转折点捕捉心脏放松和收缩之间的转换,从而在多样化的胎儿位置中实现准确且方向鲁棒的ED和ES帧定位。仅在正常胎儿超声心动图视频上训练,ORBIT在正常(ED的MAE=1.9帧,ES的MAE=1.6帧)和CHD病例(ED的MAE=2.4帧,ES的MAE=2.1帧)上均表现出一致的性能,优于现有无需标注的方法,这些方法受限于固定方向假设。这些结果突显了ORBIT在直接从4CH胎儿超声心动图中实现鲁棒心脏相位检测的潜力。

英文摘要:

Fetal echocardiography is essential for detecting congenital heart disease (CHD), facilitating pregnancy management, optimized delivery planning, and timely postnatal interventions. Among standard imaging planes, the four-chamber view (4CV) provides important information for CHD diagnosis, where clinicians carefully inspect the end-diastolic (ED) and end-systolic (ES) phases to evaluate cardiac structure and motion. Automated detection of these cardiac phases is thus a critical component towards fully automated CHD analysis. However, existing approaches typically rely on manual annotation of ED/ES frames, which is labour-intensive and time-consuming. We present ORBIT (Orientation-Robust Beat Inference from Trajectories), a self-supervised framework that identifies cardiac phases without manual annotations under various fetal heart orientation. ORBIT employs registration as self-supervision task and learns a latent motion trajectory of cardiac deformation, whose turning points capture transitions between cardiac relaxation and contraction, enabling accurate and orientation-robust localization of ED and ES frames across diverse fetal positions. Trained exclusively on normal fetal echocardiography videos, ORBIT achieves consistent performance on both normal (mean absolute error 1.9 frames for ED and 1.6 for ES) and CHD cases (mean absolute error 2.4 frames for ED and 2.1 for ES), outperforming existing annotation-free approaches constrained by fixed orientation assumptions. These results highlight the potential of ORBIT to facilitate robust cardiac phase detection directly from 4CV fetal echocardiography.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑